OP-12-68V-24V-H 12-150 V Input, 24.0 V/2.2 A Output Half-brick
$0
High conversion efficiency up to 90% with optimized thermal performance and minimal power derating.
Ultra-wide 12-150V input voltage range featuring flexible output trimming and remote sensing capabilities.
Comprehensive integrated protection suite including UVLO, OVP, short circuit protection, and thermal shutdown.
Industry-standard half-brick form factor available with standard or flanged baseplate options for versatile mounting.
Predictable EMI performance via fixed-frequency switching with no minimum load requirements for stable operation.
Safety certified with 3000V reinforced insulation and full compliance with UL/CSA/EN 60950-1 and RoHS standards.
Advanced control interface featuring input-referenced On/Off and active back-drive current limiting.
- Description
- Reviews (0)
Description
The OP-12-68V-24V-H half-brick converter series is composed of next-generation, board-mountable, isolated (REINFORCED INSULATION), fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-12-68V-24V-H |
|
|
OP-12-68V-24V-H 12-150 V Input, 24.0 V/2.2 A Output Half-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
6.8 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (enabled) (Typ.) |
60 mA |
|
No-Load Input Current (enabled) (Max.) |
80 mA |
|
Disabled Input Current (Typ.) |
3 mA |
|
Disabled Input Current (Max.) |
5 mA |
|
Response to Input Transient (Typ.) |
1.2 V |
|
Response to Input Transient (Notes & Conditions) |
See Figure 6 |
|
Input Terminal Ripple Current (Typ.) |
100 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
10 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting fuse recommended |
|
Output Voltage Set Point (Min.) |
23.8 V |
|
Output Voltage Set Point (Typ.) |
24.0 V |
|
Output Voltage Set Point (Max.) |
24.2 V |
|
Over Line (Typ.) |
+/-0.1 % |
|
Over Line (Max.) |
+/-0.3 % |
|
Over Load (Typ.) |
+/-0.1 % |
|
Over Load (Max.) |
+/-0.3 % |
|
Over Temperature (Min.) |
-360 mV |
|
Over Temperature (Max.) |
360 mV |
|
Total Output Voltage Range (Min.) |
23.40 V |
|
Total Output Voltage Range (Max.) |
24.60 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Output Voltage Ripple and Noise (Notes & Conditions) |
20 MHz bandwidth |
|
Peak-to-Peak (Typ.) |
60 mV |
|
Peak-to-Peak (Max.) |
120 mV |
|
Peak-to-Peak (Notes & Conditions) |
Full load |
|
RMS (Typ.) |
15 mV |
|
RMS (Max.) |
30 mV |
|
RMS (Notes & Conditions) |
Full load |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
2.2 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current Limit Inception (Min.) |
2.4 A |
|
Output DC Current Limit Inception (Typ.) |
2.6 A |
|
Output DC Current Limit Inception (Max.) |
2.9 A |
|
Output DC Current Limit Inception (Notes & Conditions) |
Output voltage 10 % Low |
|
Output DC Current Limit Shutdown Voltage (Typ.) |
17 V |
|
Back-Drive Current Limit while Enabled (Typ.) |
0.2 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Back-Drive Current Limit while Disabled (Typ.) |
10 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Maximum Output Capacitance (Max.) |
260 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Settling Time (Typ.) |
180 us |
|
Settling Time (Notes & Conditions) |
To within 1 % Vout nom |
|
Output Voltage Trim Range (Min.) |
-20 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8 & 4; Common Figures 3-5 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8 & 4 |
|
Output Over-Voltage Protection (Min.) |
28.1 V |
|
Output Over-Voltage Protection (Typ.) |
29.3 V |
|
Output Over-Voltage Protection (Max.) |
30.5 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
100 % Load (Typ.) |
85 % |
|
100 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50 % Load (Typ.) |
83 % |
|
50 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
12 V |
|
Operating Input Voltage Range (Typ.) |
68 V |
|
Operating Input Voltage Range (Max.) |
150 V |
|
Operating Input Voltage Range (Notes & Conditions) |
170 V transient for 100 ms |
|
Turn-On Voltage Threshold (Min.) |
10.3 V |
|
Turn-On Voltage Threshold (Typ.) |
11.0 V |
|
Turn-On Voltage Threshold (Max.) |
11.7 V |
|
Turn-Off Voltage Threshold (Min.) |
8.46 V |
|
Turn-Off Voltage Threshold (Typ.) |
9 V |
|
Turn-Off Voltage Threshold (Max.) |
9.54 V |
|
Lockout Voltage Hysteresis (Typ.) |
2.0 V |
|
Input Over-Voltage Shutdown (Min.) |
175 V |
|
Input Over-Voltage Shutdown (Typ.) |
180 V |
|
Input Over-Voltage Shutdown (Max.) |
185 V |
|
Recommended External Input Capacitance (Typ.) |
100 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1 – 0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
4.11.82 uH uF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Non-Operating (Min.) |
-1 V |
|
Non-Operating (Max.) |
170 V |
|
Non-Operating (Notes & Conditions) |
Continuous |
|
Operating (Max.) |
150 V |
|
Operating (Notes & Conditions) |
Continuous |
|
Operating Transient (Max.) |
170 V |
|
Operating Transient (Notes & Conditions) |
100 ms |
|
Insulation Voltage (Notes & Conditions) |
Reinforced insulation |
|
Input to Output (Max.) |
3000 Vdc |
|
Input to Baseplate (Max.) |
3000 Vdc |
|
Output to Baseplate (Max.) |
3000 Vdc |
|
Storage Temperature (Min.) |
-45 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
18 V |
|
Turn-On Time (Typ.) |
9 ms |
|
Turn-On Time (Notes & Conditions) |
Full load, Vout = 90 % nom. (from enable) |
|
Start-Up Inhibit Time (Min.) |
180 ms |
|
Start-Up Inhibit Time (Typ.) |
200 ms |
|
Start-Up Inhibit Time (Max.) |
220 ms |
|
Start-Up Inhibit Time (Notes & Conditions) |
-40 °C to +125 °C; Figure E |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Insulation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Insulation Resistance (Typ.) |
100 M Ohm |
|
Insulation Capacitance (input to output) (Typ.) |
1000 pF |
|
Insulation Capacitance (input to output) (Notes & Conditions) |
See Note 1 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
PCB Temperature (Max.) |
125 °C |
|
PCB Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Transformer Temperature (Notes & Conditions) |
See Common Figure 3 for derating curve |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Min.) |
255 kHz |
|
Switching Frequency (Typ.) |
275 kHz |
|
Switching Frequency (Max.) |
295 kHz |
|
Switching Frequency (Notes & Conditions) |
Regulation and Insulation stages |
|
Off-State Voltage (Min.) |
2.4 V |
|
Off-State Voltage (Max.) |
1.8 V |
|
On-State Voltage (Min.) |
-2 V |
|
On-State Voltage (Max.) |
0.8 V |
|
ON/OFF Control (Notes & Conditions) |
Application notes Figures A & B |
|
Pull-Up Voltage (Typ.) |
5 V |
|
Pull-Up Resistance (Typ.) |
50 k Ohm |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
2.5 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70 °C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
2 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70 °C |
|
Field Demonstrated MTBF (Units) |
10^6 Hrs. |
|
Field Demonstrated MTBF (Notes & Conditions) |
See our website for details |
|
Step Change in Output Current (0.05 A/ us) (Typ.) |
640 mV |
|
Step Change in Output Current (0.05 A/ us) (Notes & Conditions) |
50 % to 75 % to 50 % Iout max |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
Features |
|
|
High conversion efficiency up to 90% with optimized thermal performance and minimal power derating. |
|
|
Ultra-wide 12-150V input voltage range featuring flexible output trimming and remote sensing capabilities. |
|
|
Comprehensive integrated protection suite including UVLO, OVP, short circuit protection, and thermal shutdown. |
|
|
Industry-standard half-brick form factor available with standard or flanged baseplate options for versatile mounting. |
|
|
Predictable EMI performance via fixed-frequency switching with no minimum load requirements for stable operation. |
|
|
Safety certified with 3000V reinforced insulation and full compliance with UL/CSA/EN 60950-1 and RoHS standards. |
|
|
Advanced control interface featuring input-referenced On/Off and active back-drive current limiting. |
|
Applications |
|
|