OP-2-110V-15V-Q 66-160 V Input, 15 V/7.0 A Output Quarter-brick
$0
High efficiency up to 90% at full rated load with minimal power derating.
Wide operating input voltage range of 66-160 V with no minimum load requirement.
Fixed-frequency switching architecture for predictable and simplified EMI management.
Industry-standard Quarter-brick footprint and pin-out with optional flanged baseplate configuration.
Advanced control features including remote sense, primary-side On/Off, and wide output voltage trim.
Comprehensive protection suite including UVLO, OVP, current limit, short circuit, and thermal shutdown.
- Description
- Reviews (0)
Description
The OP-2-110V-15V-Q quarter-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-2-110V-15V-Q |
|
|
OP-2-110V-15V-Q 66-160 V Input, 15 V/7.0 A Output Quarter-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
2.3 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (enabled) (Typ.) |
40 mA |
|
No-Load Input Current (enabled) (Max.) |
50 mA |
|
Disabled Input Current (Typ.) |
2.4 mA |
|
Disabled Input Current (Max.) |
4.0 mA |
|
Response to Input Transient (Typ.) |
0.25 V |
|
Response to Input Transient (Notes & Conditions) |
See Figure 6 |
|
Input Terminal Ripple Current (Typ.) |
110 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
5 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting fuse recommended |
|
Output Voltage Set Point (Min.) |
14.85 V |
|
Output Voltage Set Point (Typ.) |
15.00 V |
|
Output Voltage Set Point (Max.) |
15.15 V |
|
Total Output Voltage Range (Min.) |
14.62 V |
|
Total Output Voltage Range (Max.) |
15.38 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
7 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current Limit Inception (Min.) |
7.7 A |
|
Output DC Current Limit Inception (Typ.) |
8.4 A |
|
Output DC Current Limit Inception (Max.) |
9.1 A |
|
Output DC Current Limit Inception (Notes & Conditions) |
Output voltage 10 % Low |
|
Output DC Current Limit Shutdown Voltage (Typ.) |
6.3 V |
|
Back-Drive Current Limit while Enabled (Typ.) |
0.97 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Back-Drive Current Limit while Disabled (Min.) |
0 mA |
|
Back-Drive Current Limit while Disabled (Typ.) |
15 mA |
|
Back-Drive Current Limit while Disabled (Max.) |
50 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Maximum Output Capacitance (Max.) |
1,000 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Output Voltage Trim Range (Min.) |
-20 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8 & 4; Common Figures 3-5 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8 & 4 |
|
Output Over-Voltage Protection (Min.) |
117 % |
|
Output Over-Voltage Protection (Typ.) |
122 % |
|
Output Over-Voltage Protection (Max.) |
127 % |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
Load Current Scale Factor (Typ.) |
325 % |
|
Load Current Scale Factor (Notes & Conditions) |
See Output Load Current app. note on our web |
|
100 % Load (Typ.) |
91 % |
|
100 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50 % Load (Typ.) |
92 % |
|
50 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
66 V |
|
Operating Input Voltage Range (Typ.) |
110 V |
|
Operating Input Voltage Range (Max.) |
160 V |
|
Operating Input Voltage Range (Notes & Conditions) |
170 V transient for 1 s |
|
Turn-On Voltage Threshold (Min.) |
60.8 V |
|
Turn-On Voltage Threshold (Typ.) |
63.5 V |
|
Turn-On Voltage Threshold (Max.) |
65.7 V |
|
Turn-Off Voltage Threshold (Min.) |
57.3 V |
|
Turn-Off Voltage Threshold (Typ.) |
60 V |
|
Turn-Off Voltage Threshold (Max.) |
62.3 V |
|
Input Over-Voltage Shutdown (Min.) |
170 V |
|
Input Over-Voltage Shutdown (Typ.) |
175 V |
|
Recommended External Input Capacitance (Typ.) |
100 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1-0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
151.1 uH uF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-45 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
18 V |
|
Turn-On Time (Typ.) |
9 ms |
|
Turn-On Time (Notes & Conditions) |
Full load, Vout = 90 % nom. (from enable) |
|
Start-Up Inhibit Time (Min.) |
180 ms |
|
Start-Up Inhibit Time (Typ.) |
200 ms |
|
Start-Up Inhibit Time (Max.) |
220 ms |
|
Start-Up Inhibit Time (Notes & Conditions) |
-40 °C to +125 °C; Figure E |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Min.) |
100 M Ohm |
|
Isolation Capacitance (input to output) (Typ.) |
1000 pF |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
PCB Temperature (Max.) |
125 °C |
|
PCB Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Transformer Temperature (Notes & Conditions) |
See Common Figure 3 for derating curve |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Min.) |
230 kHz |
|
Switching Frequency (Typ.) |
250 kHz |
|
Switching Frequency (Max.) |
270 kHz |
|
Switching Frequency (Notes & Conditions) |
Regulation and Isolation stages |
|
Pull-Up Voltage (Typ.) |
5 V |
|
Pull-Up Resistance (Typ.) |
50 k Ohm |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
1.49 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70 °C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
1.31 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70 °C |
|
Field Demonstrated MTBF (Units) |
10^6 Hrs. |
|
Field Demonstrated MTBF (Notes & Conditions) |
See our website for details |
|
Output Voltage Regulation Over Line (Typ.) |
+/-0.1 % |
|
Output Voltage Regulation Over Line (Max.) |
+/-0.3 % |
|
Output Voltage Regulation Over Load (Typ.) |
+/-0.1 % |
|
Output Voltage Regulation Over Load (Max.) |
+/-0.3 % |
|
Output Voltage Regulation Over Temperature (Min.) |
-225 mV |
|
Output Voltage Regulation Over Temperature (Max.) |
225 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Typ.) |
65 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Max.) |
130 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Notes & Conditions) |
Full load; 20 MHz bandwidth |
|
Output Voltage Ripple and Noise RMS (Typ.) |
20 mV |
|
Output Voltage Ripple and Noise RMS (Max.) |
40 mV |
|
Output Voltage Ripple and Noise RMS (Notes & Conditions) |
Full load |
|
Output Voltage during Load Current Transient Step Change (Typ.) |
600 mV |
|
Output Voltage during Load Current Transient Step Change (Notes & Conditions) |
66 % to 100 % to 66 % Iout max |
|
Output Voltage during Load Current Transient Settling Time (Typ.) |
100 us |
|
Output Voltage during Load Current Transient Settling Time (Notes & Conditions) |
To within 1 % Vout nom |
|
Lockout Hysteresis (Typ.) |
3.5 V |
|
Input Voltage Non-Operating (Min.) |
-1 V |
|
Input Voltage Non-Operating (Max.) |
170 V |
|
Input Voltage Non-Operating (Notes & Conditions) |
Continuous |
|
Input Voltage Operating (Max.) |
160 V |
|
Input Voltage Operating (Notes & Conditions) |
Continuous |
|
Input Voltage Operating Transient (Max.) |
170 V |
|
Input Voltage Operating Transient (Notes & Conditions) |
100 ms |
|
Isolation Voltage Input to Output (Max.) |
3000 Vdc |
|
Isolation Voltage Input to Output (Notes & Conditions) |
Reinforced insulation |
|
Isolation Voltage Input to Baseplate (Max.) |
3000 Vdc |
|
Isolation Voltage Output to Baseplate (Max.) |
3000 Vdc |
|
ON/OFF Control Off-State Voltage (Min.) |
2.4 V |
|
ON/OFF Control Off-State Voltage (Max.) |
1.8 V |
|
ON/OFF Control On-State Voltage (Min.) |
-2 V |
|
ON/OFF Control On-State Voltage (Max.) |
0.8 V |
Features |
|
|
High efficiency up to 90% at full rated load with minimal power derating. |
|
|
Wide operating input voltage range of 66-160 V with no minimum load requirement. |
|
|
Fixed-frequency switching architecture for predictable and simplified EMI management. |
|
|
Industry-standard Quarter-brick footprint and pin-out with optional flanged baseplate configuration. |
|
|
Advanced control features including remote sense, primary-side On/Off, and wide output voltage trim. |
|
|
Comprehensive protection suite including UVLO, OVP, current limit, short circuit, and thermal shutdown. |
|
Applications |
|
|
Industrial and Transportation applications |
|