OP-2-110V-24V-Q 66-160 V Input, 24V/4.5A Output Quarter-brick
$0
High operational efficiency up to 90% with minimal power derating at full rated load.
Wide input voltage range (66-160V) featuring fixed-frequency switching for predictable EMI management.
Industry-standard Quarter-brick footprint with an optional flanged baseplate for versatile mechanical integration.
Enhanced output control including remote sense, wide voltage trim range, and no minimum load requirement.
Comprehensive integrated protection suite featuring input UVLO, OVP, current limiting, and short circuit protection.
Advanced thermal management with integrated thermal shutdown and active back drive current limiting.
Fully compliant with international safety standards including UL/CSA/EN 60950-1, CE Marking, and RoHS.
- Description
- Reviews (0)
Description
The OP-2-110V-24V-Q quarter-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-2-110V-24V-Q |
|
|
OP-2-110V-24V-Q 66-160 V Input, 24V/4.5A Output Quarter-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
2.4 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (enabled) (Typ.) |
40 mA |
|
No-Load Input Current (enabled) (Max.) |
60 mA |
|
Disabled Input Current (Typ.) |
2.5 mA |
|
Disabled Input Current (Max.) |
4.0 mA |
|
Response to Input Transient (Typ.) |
0.35 V |
|
Response to Input Transient (Notes & Conditions) |
See Figure 6 |
|
Input Terminal Ripple Current (Typ.) |
100 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
5 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting fuse recommended |
|
Output Voltage Set Point (Min.) |
23.76 V |
|
Output Voltage Set Point (Typ.) |
24.00 V |
|
Output Voltage Set Point (Max.) |
24.24 V |
|
Over Line (Typ.) |
+/-0.1 % |
|
Over Line (Max.) |
+/-0.3 % |
|
Over Load (Typ.) |
+/-0.1 % |
|
Over Load (Max.) |
+/-0.3 % |
|
Over Temperature (Min.) |
-360 mV |
|
Over Temperature (Max.) |
360 mV |
|
Total Output Voltage Range (Min.) |
23.40 V |
|
Total Output Voltage Range (Max.) |
24.60 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Output Voltage Ripple and Noise (Notes & Conditions) |
20 MHz bandwidth |
|
Peak-to-Peak (Typ.) |
200 mV |
|
Peak-to-Peak (Max.) |
400 mV |
|
Peak-to-Peak (Notes & Conditions) |
Full load |
|
RMS (Typ.) |
50 mV |
|
RMS (Max.) |
100 mV |
|
RMS (Notes & Conditions) |
Full load |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
4.5 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current Limit Inception (Min.) |
5.0 A |
|
Output DC Current Limit Inception (Typ.) |
5.4 A |
|
Output DC Current Limit Inception (Max.) |
5.9 A |
|
Output DC Current Limit Inception (Notes & Conditions) |
Output voltage 10 % Low |
|
Output DC Current Limit Shutdown Voltage (Typ.) |
0.9 V |
|
Back-Drive Current Limit while Enabled (Typ.) |
1.1 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Back-Drive Current Limit while Disabled (Typ.) |
0.093 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Maximum Output Capacitance (Max.) |
400 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Step Change in Output Current (0.1 A/ us) (Typ.) |
75 mV |
|
Step Change in Output Current (0.1 A/ us) (Notes & Conditions) |
66 % to 100 % to 66 % Iout max |
|
Settling Time (Typ.) |
500 us |
|
Settling Time (Notes & Conditions) |
To within 1 % Vout nom |
|
Output Voltage Trim Range (Min.) |
-20 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8 & 4; Common Figures 3-5 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8 & 4 |
|
Output Over-Voltage Protection (Min.) |
117.0 % |
|
Output Over-Voltage Protection (Typ.) |
122.0 % |
|
Output Over-Voltage Protection (Max.) |
127.0 % |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
Load Current Scale Factor (Typ.) |
10 % |
|
Load Current Scale Factor (Notes & Conditions) |
See Output Load Current app. note on our web |
|
100 % Load (Typ.) |
89 % |
|
100 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50 % Load (Typ.) |
91 % |
|
50 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
66 V |
|
Operating Input Voltage Range (Typ.) |
110 V |
|
Operating Input Voltage Range (Max.) |
160 V |
|
Operating Input Voltage Range (Notes & Conditions) |
170 V transient for 1 s |
|
Turn-On Voltage Threshold (Min.) |
60.8 V |
|
Turn-On Voltage Threshold (Typ.) |
63.5 V |
|
Turn-On Voltage Threshold (Max.) |
65.7 V |
|
Turn-Off Voltage Threshold (Min.) |
57.3 V |
|
Turn-Off Voltage Threshold (Typ.) |
60 V |
|
Turn-Off Voltage Threshold (Max.) |
62.3 V |
|
Lockout Voltage Hysteresis (Typ.) |
3.5 V |
|
Input Over-Voltage Shutdown (Min.) |
170 V |
|
Input Over-Voltage Shutdown (Typ.) |
175 V |
|
Recommended External Input Capacitance (Typ.) |
100 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1-0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
151.1 uH uF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Non-Operating (Min.) |
-1 V |
|
Non-Operating (Max.) |
170 V |
|
Non-Operating (Notes & Conditions) |
Continuous |
|
Operating (Max.) |
160 V |
|
Operating (Notes & Conditions) |
Continuous |
|
Operating Transient (Max.) |
170 V |
|
Operating Transient (Notes & Conditions) |
100 ms |
|
Isolation Voltage (Notes & Conditions) |
Reinforced insulation |
|
Input to Output (Max.) |
3000 Vdc |
|
Input to Baseplate (Max.) |
3000 Vdc |
|
Output to Baseplate (Max.) |
3000 Vdc |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-45 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
18 V |
|
Turn-On Time (Typ.) |
9 ms |
|
Turn-On Time (Notes & Conditions) |
Full load, Vout = 90 % nom. (from enable) |
|
Start-Up Inhibit Time (Min.) |
180 ms |
|
Start-Up Inhibit Time (Typ.) |
200 ms |
|
Start-Up Inhibit Time (Max.) |
220 ms |
|
Start-Up Inhibit Time (Notes & Conditions) |
-40 °C to +125 °C; Figure E |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Min.) |
100 M Ohm |
|
Isolation Capacitance (input to output) (Typ.) |
1000 pF |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
PCB Temperature (Max.) |
125 °C |
|
PCB Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Transformer Temperature (Notes & Conditions) |
See Common Figure 3 for derating curve |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Min.) |
230 kHz |
|
Switching Frequency (Typ.) |
250 kHz |
|
Switching Frequency (Max.) |
270 kHz |
|
Switching Frequency (Notes & Conditions) |
Regulation and Isolation stages |
|
Off-State Voltage (Min.) |
2.4 V |
|
Off-State Voltage (Max.) |
1.8 V |
|
On-State Voltage (Min.) |
-2 V |
|
On-State Voltage (Max.) |
0.8 V |
|
ON/OFF Control (Notes & Conditions) |
Application notes Figures A & B |
|
Pull-Up Voltage (Typ.) |
5 V |
|
Pull-Up Resistance (Typ.) |
50 k Ohm |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
1.49 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70 °C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
1.31 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70 °C |
|
Field Demonstrated MTBF (Units) |
10^6 Hrs. |
|
Field Demonstrated MTBF (Notes & Conditions) |
See our website for details |
Features |
|
|
High operational efficiency up to 90% with minimal power derating at full rated load. |
|
|
Wide input voltage range (66-160V) featuring fixed-frequency switching for predictable EMI management. |
|
|
Industry-standard Quarter-brick footprint with an optional flanged baseplate for versatile mechanical integration. |
|
|
Enhanced output control including remote sense, wide voltage trim range, and no minimum load requirement. |
|
|
Comprehensive integrated protection suite featuring input UVLO, OVP, current limiting, and short circuit protection. |
|
|
Advanced thermal management with integrated thermal shutdown and active back drive current limiting. |
|
|
Fully compliant with international safety standards including UL/CSA/EN 60950-1, CE Marking, and RoHS. |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews
There are no reviews yet.