OP-2-110V-30V-Q 66-160 V Input, 30 V/3.5 A Output Quarter-brick

$0

High operational efficiency up to 90% with minimal power derating for optimized thermal performance.
Wide 66-160 V input range featuring fixed frequency switching for predictable EMI management.
Industry-standard quarter-brick footprint with available flanged baseplate for versatile mechanical integration.
Advanced control features including remote sensing, wide output voltage trim, and input-referenced On/Off control.
Robust protection suite featuring input UVLO, output over-voltage, current limit, short circuit, and thermal shutdown.
Reliable operation with no minimum load requirement and integrated active back drive current limiting.
Full compliance with international safety standards including UL/CSA/EN 60950-1, CE marking, and RoHS directives.

SKU: OP-2-110V-30V-Q Category: converter

Description

The OP-2-110V-30V-Q quarter-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.

OP-2-110V-30V-Q

OP-2-110V-30V-Q 66-160 V Input, 30 V/3.5 A Output Quarter-brick

 

Property

Value

Maximum Input Current (Max.)

2.4 A

Maximum Input Current (Notes & Conditions)

Vin min; trim up; in current limit

No-Load Input Current (enabled) (Typ.)

40 mA

No-Load Input Current (enabled) (Max.)

50 mA

Disabled Input Current (Typ.)

2.5 mA

Disabled Input Current (Max.)

4 mA

Response to Input Transient (Typ.)

0.45 V

Response to Input Transient (Notes & Conditions)

See Figure 6

Input Terminal Ripple Current (Typ.)

100 mA

Input Terminal Ripple Current (Notes & Conditions)

RMS

Recommended Input Fuse (Max.)

5 A

Recommended Input Fuse (Notes & Conditions)

Fast acting fuse recommended

Output Voltage Set Point (Min.)

29.70 V

Output Voltage Set Point (Typ.)

30.00 V

Output Voltage Set Point (Max.)

30.30 V

Over Line (Typ.)

+/-0.1 %

Over Line (Max.)

+/-0.3 %

Over Load (Typ.)

+/-0.1 %

Over Load (Max.)

+/-0.3 %

Over Temperature (Min.)

-450 mV

Over Temperature (Max.)

450 mV

Total Output Voltage Range (Min.)

29.25 V

Total Output Voltage Range (Max.)

30.75 V

Total Output Voltage Range (Notes & Conditions)

Over sample, line, load, temperature & life

Output Voltage Ripple and Noise (Notes & Conditions)

20 MHz bandwidth

Peak-to-Peak (Typ.)

180 mV

Peak-to-Peak (Max.)

360 mV

Peak-to-Peak (Notes & Conditions)

Full load

RMS (Typ.)

40 mV

RMS (Max.)

80 mV

RMS (Notes & Conditions)

Full load

Operating Output Current Range (Min.)

0 A

Operating Output Current Range (Max.)

3.5 A

Operating Output Current Range (Notes & Conditions)

Subject to thermal derating

Output DC Current Limit Inception (Min.)

3.9 A

Output DC Current Limit Inception (Typ.)

4.2 A

Output DC Current Limit Inception (Max.)

4.6 A

Output DC Current Limit Inception (Notes & Conditions)

Output voltage 10 % Low

Output DC Current Limit Shutdown Voltage (Typ.)

12.9 V

Back-Drive Current Limit while Enabled (Typ.)

0.3 A

Back-Drive Current Limit while Enabled (Notes & Conditions)

Negative current drawn into output pins

Back-Drive Current Limit while Disabled (Min.)

0 mA

Back-Drive Current Limit while Disabled (Typ.)

15 mA

Back-Drive Current Limit while Disabled (Max.)

50 mA

Back-Drive Current Limit while Disabled (Notes & Conditions)

Negative current drawn into output pins

Maximum Output Capacitance (Max.)

250 uF

Maximum Output Capacitance (Notes & Conditions)

Vout nominal at full load (resistive load)

Settling Time (Typ.)

50 us

Settling Time (Notes & Conditions)

To within 1 % Vout nom

Output Voltage Trim Range (Min.)

-20 %

Output Voltage Trim Range (Max.)

10 %

Output Voltage Trim Range (Notes & Conditions)

Across Pins 8 & 4; Common Figures 3-5

Output Voltage Remote Sense Range (Max.)

10 %

Output Voltage Remote Sense Range (Notes & Conditions)

Across Pins 8 & 4

Output Over-Voltage Protection (Min.)

117 %

Output Over-Voltage Protection (Typ.)

122 %

Output Over-Voltage Protection (Max.)

127 %

Output Over-Voltage Protection (Notes & Conditions)

Over full temp range

Load Current Scale Factor (Typ.)

156 %

Load Current Scale Factor (Notes & Conditions)

See Output Load Current app. note on our web

100 % Load (Typ.)

88 %

100 % Load (Notes & Conditions)

See Figure 1 for efficiency curve

50 % Load (Typ.)

91 %

50 % Load (Notes & Conditions)

See Figure 1 for efficiency curve

Operating Input Voltage Range (Min.)

66 V

Operating Input Voltage Range (Typ.)

110 V

Operating Input Voltage Range (Max.)

160 V

Operating Input Voltage Range (Notes & Conditions)

170 V transient for 1 s

Turn-On Voltage Threshold (Min.)

60.8 V

Turn-On Voltage Threshold (Typ.)

63.5 V

Turn-On Voltage Threshold (Max.)

65.7 V

Turn-Off Voltage Threshold (Min.)

57.3 V

Turn-Off Voltage Threshold (Typ.)

60 V

Turn-Off Voltage Threshold (Max.)

62.3 V

Lockout Voltage Hysteresis (Typ.)

3.5 V

Input Over-Voltage Shutdown (Min.)

170 V

Input Over-Voltage Shutdown (Typ.)

175 V

Recommended External Input Capacitance (Typ.)

100 uF

Recommended External Input Capacitance (Notes & Conditions)

Typical ESR 0.1-0.2 Ohm

Input Filter Component Values (LC) (Typ.)

151.1 uHuF

Input Filter Component Values (LC) (Notes & Conditions)

Internal values

Non-Operating (Min.)

-1 V

Non-Operating (Max.)

170 V

Non-Operating (Notes & Conditions)

Continuous

Operating (Max.)

160 V

Operating (Notes & Conditions)

Continuous

Operating Transient (Max.)

170 V

Operating Transient (Notes & Conditions)

100 ms

Isolation Voltage (Notes & Conditions)

Reinforced insulation

Input to Output (Max.)

3000 Vdc

Input to Baseplate (Max.)

3000 Vdc

Output to Baseplate (Max.)

3000 Vdc

Operating Temperature (Min.)

-40 °C

Operating Temperature (Max.)

100 °C

Operating Temperature (Notes & Conditions)

Baseplate temperature

Storage Temperature (Min.)

-45 °C

Storage Temperature (Max.)

125 °C

Voltage at ON/OFF input pin (Min.)

-2 V

Voltage at ON/OFF input pin (Max.)

18 V

Turn-On Time (Typ.)

9 ms

Turn-On Time (Notes & Conditions)

Full load, Vout = 90 % nom. (from enable)

Start-Up Inhibit Time (Min.)

180 ms

Start-Up Inhibit Time (Typ.)

200 ms

Start-Up Inhibit Time (Max.)

220 ms

Start-Up Inhibit Time (Notes & Conditions)

-40 °C to +125 °C; Figure E

Output Voltage Overshoot (Typ.)

0 %

Output Voltage Overshoot (Notes & Conditions)

Maximum Output Capacitance

Isolation Voltage (dielectric strength) (Notes & Conditions)

See Absolute Maximum Ratings

Isolation Resistance (Min.)

100 M Ohm

Isolation Capacitance (input to output) (Typ.)

1000 pF

Semiconductor Junction Temperature (Max.)

125 °C

Semiconductor Junction Temperature (Notes & Conditions)

Package rated to 150 °C

PCB Temperature (Max.)

125 °C

PCB Temperature (Notes & Conditions)

UL rated max operating temp 130 °C

Transformer Temperature (Max.)

125 °C

Transformer Temperature (Notes & Conditions)

See Common Figure 3 for derating curve

Maximum Baseplate Temperature, Tb (Max.)

100 °C

Switching Frequency (Min.)

230 kHz

Switching Frequency (Typ.)

250 kHz

Switching Frequency (Max.)

270 kHz

Switching Frequency (Notes & Conditions)

Regulation and Isolation stages

Off-State Voltage (Min.)

2.4 V

Off-State Voltage (Max.)

1.8 V

On-State Voltage (Min.)

-2 V

On-State Voltage (Max.)

0.8 V

ON/OFF Control (Notes & Conditions)

Application notes Figures A & B

Pull-Up Voltage (Typ.)

5 V

Pull-Up Resistance (Typ.)

50 k Ohm

Over-Temperature Shutdown OTP Trip Point (Typ.)

125 °C

Over-Temperature Shutdown OTP Trip Point (Notes & Conditions)

Average PCB Temperature

Over-Temperature Shutdown Restart Hysteresis (Typ.)

10 °C

Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.)

1.49 10⁶ Hrs.

Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions)

Tb = 70 °C

Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.)

1.31 10⁶ Hrs.

Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions)

Tb = 70 °C

Field Demonstrated MTBF (Units)

10⁶ Hrs.

Field Demonstrated MTBF (Notes & Conditions)

See our website for details

Step Change in Output Current (0.1 A/us) (Typ.)

1850 mV

Step Change in Output Current (0.1 A/us) (Notes & Conditions)

66 % to 100 % to 66 % Iout max

Features

High operational efficiency up to 90% with minimal power derating for optimized thermal performance.

Wide 66-160 V input range featuring fixed frequency switching for predictable EMI management.

Industry-standard quarter-brick footprint with available flanged baseplate for versatile mechanical integration.

Advanced control features including remote sensing, wide output voltage trim, and input-referenced On/Off control.

Robust protection suite featuring input UVLO, output over-voltage, current limit, short circuit, and thermal shutdown.

Reliable operation with no minimum load requirement and integrated active back drive current limiting.

Full compliance with international safety standards including UL/CSA/EN 60950-1, CE marking, and RoHS directives.

Applications

Industrial and Transportation applications