OP-2-12V-24V-H 9-22 V Input, 24 V/6 A Output Half-brick

High operational efficiency up to 92% with full power delivery and minimal thermal derating.
Versatile 9-22V input voltage range featuring integrated under-voltage lockout and over-voltage shutdown.
Enhanced output regulation including remote sensing, wide-range voltage trimming, and no minimum load requirement.
Comprehensive protection suite covering output over-voltage, current limit, short circuit, and thermal shutdown.
Fixed-frequency switching architecture for predictable EMI performance and active back-drive current limiting.
Industry-standard half-brick footprint available with an optional flanged baseplate for robust mechanical mounting.
Fully certified to UL/CSA/EN 62368-1 safety standards and compliant with RoHS environmental directives.

SKU: OP-2-12V-24V-H Categories: Isolated DC-DC Power Converters, RF Antenna

Description

The OP-2-12V-24V-H Half-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.

OP-2-12V-24V-H

OP-2-12V-24V-H 9-22 V Input, 24 V/6 A Output Half-brick

 

Property

Value

Maximum Input Current (Max.)

23.5 A

Maximum Input Current (Notes & Conditions)

Vin min; trim up; in current limit

No-Load Input Current (enabled) (Typ.)

330 mA

No-Load Input Current (enabled) (Max.)

410 mA

Disabled Input Current (Typ.)

2 mA

Disabled Input Current (Max.)

3 mA

Response to Input Transient (Typ.)

0.7 V

Response to Input Transient (Notes & Conditions)

500 V/ms

Input Terminal Ripple Current (Typ.)

360 mA

Input Terminal Ripple Current (Notes & Conditions)

RMS

Recommended Input Fuse (Max.)

30 A

Recommended Input Fuse (Notes & Conditions)

Fast acting fuse recommended

Output Voltage Set Point (Min.)

23.76 V

Output Voltage Set Point (Typ.)

24.00 V

Output Voltage Set Point (Max.)

24.24 V

Total Output Voltage Range (Min.)

23.40 V

Total Output Voltage Range (Max.)

24.60 V

Total Output Voltage Range (Notes & Conditions)

Over sample, line, load, temperature & life

Peak-to-Peak (Typ.)

150 mV

Peak-to-Peak (Max.)

300 mV

Peak-to-Peak (Notes & Conditions)

Full load

RMS (Typ.)

21 mV

RMS (Max.)

40 mV

RMS (Notes & Conditions)

Full load

Operating Output Current Range (Min.)

0 A

Operating Output Current Range (Max.)

6 A

Operating Output Current Range (Notes & Conditions)

Subject to thermal derating

Output DC Current Limit Inception (Min.)

6.6 A

Output DC Current Limit Inception (Typ.)

7.2 A

Output DC Current Limit Inception (Max.)

7.8 A

Output DC Current Limit Inception (Notes & Conditions)

Output voltage 10 % Low

Output DC Current Limit Shutdown Voltage (Typ.)

13 V

Back-Drive Current Limit while Enabled (Typ.)

0.2 A

Back-Drive Current Limit while Enabled (Notes & Conditions)

Negative current drawn into output pins

Back-Drive Current Limit while Disabled (Typ.)

2.5 mA

Back-Drive Current Limit while Disabled (Notes & Conditions)

Negative current drawn into output pins

Maximum Output Capacitance (Max.)

400 uF

Maximum Output Capacitance (Notes & Conditions)

Vout nominal at full load (resistive load)

Step Change in Output Current (0.1 A/ us) (Typ.)

1400 mV

Step Change in Output Current (0.1 A/ us) (Notes & Conditions)

66 % to 100 % to 66 % Iout max

Settling Time (Typ.)

80 us

Settling Time (Notes & Conditions)

To within 1 % Vout nom

Output Voltage Trim Range (Min.)

-20 %

Output Voltage Trim Range (Max.)

10 %

Output Voltage Trim Range (Notes & Conditions)

Across Pins 8 & 4; Common Figures 3-5

Output Voltage Remote Sense Range (Max.)

10 %

Output Voltage Remote Sense Range (Notes & Conditions)

Across Pins 8 & 4

Output Over-Voltage Protection (Min.)

28.1 V

Output Over-Voltage Protection (Typ.)

29.3 V

Output Over-Voltage Protection (Max.)

30.5 V

Output Over-Voltage Protection (Notes & Conditions)

Over full temp range

100 % Load (Typ.)

90 %

100 % Load (Notes & Conditions)

See Figure 1 for efficiency curve

50 % Load (Typ.)

91 %

50 % Load (Notes & Conditions)

See Figure 1 for efficiency curve

Operating Input Voltage Range (Min.)

9 V

Operating Input Voltage Range (Typ.)

12 V

Operating Input Voltage Range (Max.)

22 V

Operating Input Voltage Range (Notes & Conditions)

See Note 1

Turn-On Voltage Threshold (Min.)

9.2 V

Turn-On Voltage Threshold (Typ.)

9.5 V

Turn-On Voltage Threshold (Max.)

9.8 V

Turn-Off Voltage Threshold (Min.)

8.3 V

Turn-Off Voltage Threshold (Typ.)

8.6 V

Turn-Off Voltage Threshold (Max.)

8.9 V

Lockout Voltage Hysteresis (Typ.)

0.9 V

Input Over-Voltage Shutdown (Min.)

32 V

Input Over-Voltage Shutdown (Typ.)

35 V

Recommended External Input Capacitance (Typ.)

820 uF

Recommended External Input Capacitance (Notes & Conditions)

Typical ESR 0.1-0.2 Ω

Input Filter Component Values (LC) (Typ.)

0.3432 uH uF

Input Filter Component Values (LC) (Notes & Conditions)

Internal values

Operating Temperature (Min.)

-40 °C

Operating Temperature (Max.)

100 °C

Operating Temperature (Notes & Conditions)

Baseplate temperature

Storage Temperature (Min.)

-45 °C

Storage Temperature (Max.)

125 °C

Voltage at ON/OFF input pin (Min.)

-2 V

Voltage at ON/OFF input pin (Max.)

18 V

Turn-On Time (Typ.)

10 ms

Turn-On Time (Notes & Conditions)

Full load, Vout = 90 % nom. (from enable)

Start-Up Inhibit Time (Min.)

180 ms

Start-Up Inhibit Time (Typ.)

200 ms

Start-Up Inhibit Time (Max.)

220 ms

Start-Up Inhibit Time (Notes & Conditions)

Figure E

Output Voltage Overshoot (Typ.)

0 %

Output Voltage Overshoot (Notes & Conditions)

Maximum Output Capacitance

Isolation Voltage (dielectric strength) (Notes & Conditions)

See Absolute Maximum Ratings

Isolation Resistance (Typ.)

30 MΩ

Isolation Capacitance (input to output) (Typ.)

1000 pF

Isolation Capacitance (input to output) (Notes & Conditions)

See Note 2

Semiconductor Junction Temperature (Max.)

125 °C

Semiconductor Junction Temperature (Notes & Conditions)

Package rated to 150 °C

PCB Temperature (Max.)

125 °C

PCB Temperature (Notes & Conditions)

UL rated max operating temp 130 °C

Transformer Temperature (Max.)

125 °C

Maximum Baseplate Temperature, Tb (Max.)

100 °C

Switching Frequency (Min.)

255 kHz

Switching Frequency (Typ.)

275 kHz

Switching Frequency (Max.)

295 kHz

Switching Frequency (Notes & Conditions)

Isolation stage switching freq. is half this

Off-State Voltage (Min.)

2.4 V

Off-State Voltage (Max.)

18 V

On-State Voltage (Min.)

-2 V

On-State Voltage (Max.)

0.8 V

Pull-Up Voltage (Typ.)

5 V

Pull-Up Resistance (Typ.)

50 kΩ

Over-Temperature Shutdown OTP Trip Point (Typ.)

125 °C

Over-Temperature Shutdown OTP Trip Point (Notes & Conditions)

Average PCB Temperature

Over-Temperature Shutdown Restart Hysteresis (Typ.)

10 °C

Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.)

1.44 10^6 Hrs.

Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions)

Tb = 70 °C

Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.)

1.20 10^6 Hrs.

Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions)

Tb = 70 °C

Over Line (Typ.)

+/-0.1 %

Over Line (Max.)

+/-0.3 %

Over Load (Typ.)

+/-0.1 %

Over Load (Max.)

+/-0.3 %

Over Temperature (Min.)

-360 mV

Over Temperature (Max.)

360 mV

Output Voltage Ripple and Noise (Notes & Conditions)

20 MHz bandwidth

Non-Operating (Min.)

-0.5 V

Non-Operating (Max.)

30 V

Non-Operating (Notes & Conditions)

Continuous

Operating (Max.)

22 V

Operating (Notes & Conditions)

Continuous

Operating Transient (Max.)

25 V

Input to Output (Max.)

2250 Vdc

Input to Baseplate (Max.)

2250 Vdc

Output to Baseplate (Max.)

2250 Vdc

ON/OFF Control (Notes & Conditions)

Application notes Figures A & B

Features

High operational efficiency up to 92% with full power delivery and minimal thermal derating.

Versatile 9-22V input voltage range featuring integrated under-voltage lockout and over-voltage shutdown.

Enhanced output regulation including remote sensing, wide-range voltage trimming, and no minimum load requirement.

Comprehensive protection suite covering output over-voltage, current limit, short circuit, and thermal shutdown.

Fixed-frequency switching architecture for predictable EMI performance and active back-drive current limiting.

Industry-standard half-brick footprint available with an optional flanged baseplate for robust mechanical mounting.

Fully certified to UL/CSA/EN 62368-1 safety standards and compliant with RoHS environmental directives.

Applications

Industrial and Transportation applications

Reviews

There are no reviews yet.


Be the first to review “OP-2-12V-24V-H 9-22 V Input, 24 V/6 A Output Half-brick”