OP-2-24V-12V-Q 18-36 V Input, 12 V/10 A Output Quarter-brick
$0
High operating efficiency up to 93% at full load with minimal power derating.
Wide 18-36 V input range with fixed-frequency switching for predictable EMI.
Industry-standard Quarter-brick footprint with optional flanged baseplate for versatile mounting.
Advanced control features including remote sense, wide output trim, and remote On/Off.
Comprehensive protection suite including input UVLO, output OVP, thermal shutdown, and short-circuit protection.
Certified to UL/CSA/EN 62368-1 safety standards and fully RoHS compliant.
Stable performance with no minimum load requirement and active back-drive current limiting.
- Description
- Reviews (0)
Description
The OP-2-24V-12V-Q quarter-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased in provide protection from the harsh environments seen in many industrial and transportation applications.
OP-2-24V-12V-Q |
|
|
OP-2-24V-12V-Q 18-36 V Input, 12 V/10 A Output Quarter-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
9.6 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (enabled) (Min.) |
90 mA |
|
No-Load Input Current (enabled) (Typ.) |
125 mA |
|
No-Load Input Current (enabled) (Max.) |
155 mA |
|
Disabled Input Current (Typ.) |
2 mA |
|
Disabled Input Current (Max.) |
4 mA |
|
Response to Input Transient (Typ.) |
0.17 V |
|
Response to Input Transient (Notes & Conditions) |
See Figure 6 |
|
Input Terminal Ripple Current (Typ.) |
220 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
20 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting fuse recommended |
|
Output Voltage Set Point (Min.) |
11.88 V |
|
Output Voltage Set Point (Typ.) |
12.00 V |
|
Output Voltage Set Point (Max.) |
12.12 V |
|
Over Line (Typ.) |
+/-0.1 % |
|
Over Line (Max.) |
+/-0.3 % |
|
Over Load (Typ.) |
+/-0.1 % |
|
Over Load (Max.) |
+/-0.3 % |
|
Over Temperature (Min.) |
-180 mV |
|
Over Temperature (Max.) |
180 mV |
|
Total Output Voltage Range (Min.) |
11.70 V |
|
Total Output Voltage Range (Max.) |
12.30 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Peak-to-Peak (Typ.) |
55 mV |
|
Peak-to-Peak (Max.) |
110 mV |
|
Peak-to-Peak (Notes & Conditions) |
20 MHz bandwidth |
|
RMS (Typ.) |
10 mV |
|
RMS (Max.) |
20 mV |
|
RMS (Notes & Conditions) |
Full load |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
10 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current Limit Inception (Min.) |
11.0 A |
|
Output DC Current Limit Inception (Typ.) |
12.0 A |
|
Output DC Current Limit Inception (Max.) |
13.0 A |
|
Output DC Current Limit Inception (Notes & Conditions) |
Output voltage 10% Low |
|
Output DC Current Limit Shutdown Voltage (Typ.) |
5 V |
|
Back-Drive Current Limit while Enabled (Typ.) |
0.45 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn from output pins |
|
Back-Drive Current Limit while Disabled (Typ.) |
15 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn from output pins |
|
Maximum Output Capacitance (Max.) |
1,500 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Step Change in Output Current (0.1 A/ us) (Typ.) |
340 mV |
|
Step Change in Output Current (0.1 A/ us) (Notes & Conditions) |
50% to 75% to 50% Iout max |
|
Settling Time (Typ.) |
100 us |
|
Settling Time (Notes & Conditions) |
To within 1% Vout nom |
|
Output Voltage Trim Range (Min.) |
-20 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8&4; Common Figures 3-5 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8 & 4 |
|
Output Over-Voltage Protection (Min.) |
13.6 V |
|
Output Over-Voltage Protection (Typ.) |
14.6 V |
|
Output Over-Voltage Protection (Max.) |
15.6 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
100% Load (Typ.) |
92 % |
|
100% Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50% Load (Typ.) |
92 % |
|
50% Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
18 V |
|
Operating Input Voltage Range (Typ.) |
24 V |
|
Operating Input Voltage Range (Max.) |
36 V |
|
Turn-On Voltage Threshold (Min.) |
17.1 V |
|
Turn-On Voltage Threshold (Typ.) |
17.5 V |
|
Turn-On Voltage Threshold (Max.) |
17.9 V |
|
Turn-Off Voltage Threshold (Min.) |
16.0 V |
|
Turn-Off Voltage Threshold (Typ.) |
16.5 V |
|
Turn-Off Voltage Threshold (Max.) |
16.9 V |
|
Lockout Voltage Hysteresis (Typ.) |
1.0 V |
|
Input Over-Voltage Shutdown (Typ.) |
– V |
|
Input Over-Voltage Shutdown (Notes & Conditions) |
Not Available |
|
Recommended External Input Capacitance (Typ.) |
100.0 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1-0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
1.06.6 uH uF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Input Voltage (Non-Operating) (Min.) |
-1 V |
|
Input Voltage (Non-Operating) (Max.) |
60 V |
|
Input Voltage (Non-Operating) (Notes & Conditions) |
Continuous |
|
Input Voltage (Operating) (Max.) |
36 V |
|
Input Voltage (Operating) (Notes & Conditions) |
Continuous |
|
Input Voltage (Operating Transient Protection) (Max.) |
50 V |
|
Input Voltage (Operating Transient Protection) (Notes & Conditions) |
1 s transient |
|
Isolation Voltage (Input to Output) (Max.) |
2250 Vdc |
|
Isolation Voltage (Input to Baseplate) (Max.) |
2250 Vdc |
|
Isolation Voltage (Output to Baseplate) (Max.) |
2250 Vdc |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-45 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
18 V |
|
Turn-On Time (Typ.) |
9 ms |
|
Turn-On Time (Notes & Conditions) |
Full load, Vout = 90% nom. (from enable) |
|
Start-Up Inhibit Time (Min.) |
180 ms |
|
Start-Up Inhibit Time (Typ.) |
200 ms |
|
Start-Up Inhibit Time (Max.) |
220 ms |
|
Start-Up Inhibit Time (Notes & Conditions) |
Figure E |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Min.) |
30 M Ohm |
|
Isolation Capacitance (input to output) (Typ.) |
1000 pF |
|
Isolation Capacitance (input to output) (Notes & Conditions) |
See Note 1 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
PCB Temperature (Max.) |
125 °C |
|
PCB Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Min.) |
230 kHz |
|
Switching Frequency (Typ.) |
250 kHz |
|
Switching Frequency (Max.) |
270 kHz |
|
Switching Frequency (Notes & Conditions) |
Isolation stage switching freq. is the same |
|
Off-State Voltage (Min.) |
2.4 V |
|
Off-State Voltage (Max.) |
18 V |
|
On-State Voltage (Min.) |
-2 V |
|
On-State Voltage (Max.) |
0.8 V |
|
Pull-Up Voltage (Typ.) |
5 V |
|
Pull-Up Voltage (Notes & Conditions) |
Application notes Figures A & B |
|
Pull-Up Resistance (Typ.) |
50 k Ohm |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
1.49 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70 °C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
1.31 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70 °C |
Features |
|
|
High operating efficiency up to 93% at full load with minimal power derating. |
|
|
Wide 18-36 V input range with fixed-frequency switching for predictable EMI. |
|
|
Industry-standard Quarter-brick footprint with optional flanged baseplate for versatile mounting. |
|
|
Advanced control features including remote sense, wide output trim, and remote On/Off. |
|
|
Comprehensive protection suite including input UVLO, output OVP, thermal shutdown, and short-circuit protection. |
|
|
Certified to UL/CSA/EN 62368-1 safety standards and fully RoHS compliant. |
|
|
Stable performance with no minimum load requirement and active back-drive current limiting. |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews
There are no reviews yet.