OP-2-24V-15V-H 18-36 V Input, 15 V/15 A Output Half-Brick
$0
High efficiency, up to 92 % at full rated load current
Delivers full power with minimal derating
Operating input voltage range: 18-36 V
Fixed frequency switching provides predictable EMI
No minimum load requirement
Industry standard half-brick pin-out
Standard size: 2.39″ x 2.49″ x 0.51″, 60.6 x 63.1 x 13.0 mm
Total weight: 4.7 oz (133 g)
Flanged baseplate version available
On/Off control referenced to input side
Remote sense for improved output voltage control
Wide output trim range
Input under-voltage lockout
Input over-voltage shutdown
Output current limit and short circuit protection
Active back drive current limit
Thermal shutdown
UL 60950-1:2007/A2:2014 Basic Insulation
CAN/CSA C22.2 No. 60950-1:2007/A2:2014
EN 60950-1:2006/A2:2013
RoHS compliant (see last page)
- Description
- Reviews (0)
Description
The OP-2-24V-15V-H half-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-2-24V-15V-H |
|
|
OP-2-24V-15V-H 18-36 V Input, 15 V/15 A Output Half-Brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
17.8 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (enabled) (Typ.) |
140 mA |
|
No-Load Input Current (enabled) (Max.) |
180 mA |
|
Disabled Input Current (Typ.) |
1.5 mA |
|
Disabled Input Current (Max.) |
3 mA |
|
Response to Input Transient (Typ.) |
0.85 V |
|
Response to Input Transient (Notes & Conditions) |
See Figure 6 |
|
Input Terminal Ripple Current (Typ.) |
250 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
20 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting fuse recommended |
|
Output Voltage Set Point (Min.) |
14.85 V |
|
Output Voltage Set Point (Typ.) |
15.00 V |
|
Output Voltage Set Point (Max.) |
15.15 V |
|
Over Line (Typ.) |
+/-0.1 % |
|
Over Line (Max.) |
+/-0.3 % |
|
Over Load (Typ.) |
+/-0.1 % |
|
Over Load (Max.) |
+/-0.3 % |
|
Over Temperature (Min.) |
-225 mV |
|
Over Temperature (Max.) |
225 mV |
|
Total Output Voltage Range (Min.) |
14.62 V |
|
Total Output Voltage Range (Max.) |
15.38 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Output Voltage Ripple and Noise (Notes & Conditions) |
20 MHz bandwidth |
|
Peak-to-Peak (Typ.) |
125 mV |
|
Peak-to-Peak (Max.) |
250 mV |
|
Peak-to-Peak (Notes & Conditions) |
Full load |
|
RMS (Typ.) |
20 mV |
|
RMS (Max.) |
40 mV |
|
RMS (Notes & Conditions) |
Full load |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
15 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current Limit Inception (Min.) |
16.5 A |
|
Output DC Current Limit Inception (Typ.) |
18.0 A |
|
Output DC Current Limit Inception (Max.) |
19.5 A |
|
Output DC Current Limit Inception (Notes & Conditions) |
Output voltage 10 % Low |
|
Output DC Current Limit Shutdown Voltage (Typ.) |
7 V |
|
Back-Drive Current Limit while Enabled (Typ.) |
0.3 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Back-Drive Current Limit while Disabled (Typ.) |
1 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Maximum Output Capacitance (Max.) |
1,000 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Settling Time (Typ.) |
100 us |
|
Settling Time (Notes & Conditions) |
To within 1 % Vout nom |
|
Output Voltage Trim Range (Min.) |
-20 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8 & 4; Common Figures 3-5 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8 & 4 |
|
Output Over-Voltage Protection (Min.) |
17.6 V |
|
Output Over-Voltage Protection (Typ.) |
18.3 V |
|
Output Over-Voltage Protection (Max.) |
19.1 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
100 % Load (Typ.) |
92 % |
|
100 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50 % Load (Typ.) |
93 % |
|
50 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
18 V |
|
Operating Input Voltage Range (Typ.) |
24 V |
|
Operating Input Voltage Range (Max.) |
36 V |
|
Operating Input Voltage Range (Notes & Conditions) |
50 V transient for 1 s |
|
Turn-On Voltage Threshold (Min.) |
17.1 V |
|
Turn-On Voltage Threshold (Typ.) |
17.5 V |
|
Turn-On Voltage Threshold (Max.) |
17.9 V |
|
Turn-Off Voltage Threshold (Min.) |
16.0 V |
|
Turn-Off Voltage Threshold (Typ.) |
16.5 V |
|
Turn-Off Voltage Threshold (Max.) |
16.9 V |
|
Lockout Voltage Hysteresis (Typ.) |
1.0 V |
|
Input Over-Voltage Shutdown (Min.) |
52 V |
|
Input Over-Voltage Shutdown (Typ.) |
55 V |
|
Recommended External Input Capacitance (Typ.) |
470 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1-0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
1.113.2 uHuF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Non-Operating (Min.) |
-1 V |
|
Non-Operating (Max.) |
60 V |
|
Non-Operating (Notes & Conditions) |
Continuous |
|
Operating (Max.) |
36 V |
|
Operating (Notes & Conditions) |
Continuous |
|
Operating Transient (Max.) |
50 V |
|
Operating Transient (Notes & Conditions) |
1 s transient, square wave |
|
Input to Output (Max.) |
2250 Vdc |
|
Input to Baseplate (Max.) |
2250 Vdc |
|
Output to Baseplate (Max.) |
2250 Vdc |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-45 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
18 V |
|
Turn-On Time (Typ.) |
10 ms |
|
Turn-On Time (Notes & Conditions) |
Full load, Vout=90 % nom. (from enable) |
|
Start-Up Inhibit Time (Min.) |
180 ms |
|
Start-Up Inhibit Time (Typ.) |
200 ms |
|
Start-Up Inhibit Time (Max.) |
220 ms |
|
Start-Up Inhibit Time (Notes & Conditions) |
Figure E |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Typ.) |
30 M Ohm |
|
Isolation Capacitance (input to output) (Typ.) |
1000 pF |
|
Isolation Capacitance (input to output) (Notes & Conditions) |
See Note 1 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
PCB Temperature (Max.) |
125 °C |
|
PCB Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Min.) |
255 kHz |
|
Switching Frequency (Typ.) |
275 kHz |
|
Switching Frequency (Max.) |
295 kHz |
|
Switching Frequency (Notes & Conditions) |
Isolation stage switching freq. is half this |
|
Off-State Voltage (Min.) |
2.4 V |
|
Off-State Voltage (Max.) |
18 V |
|
On-State Voltage (Min.) |
-2 V |
|
On-State Voltage (Max.) |
0.8 V |
|
ON/OFF Control (Notes & Conditions) |
Application notes Figures A & B |
|
Pull-Up Voltage (Typ.) |
5 V |
|
Pull-Up Resistance (Typ.) |
50 k Ohm |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
1.44 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70 °C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
1.20 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70 °C |
|
Field Demonstrated MTBF (Units) |
10^6 Hrs. |
|
Field Demonstrated MTBF (Notes & Conditions) |
See our website for details |
|
Step Change in Output Current (0.2 A/us) (Typ.) |
550 mV |
|
Step Change in Output Current (0.2 A/us) (Notes & Conditions) |
50 % to 75 % to 50 % Iout max |
Features |
|
|
High efficiency, up to 92 % at full rated load current |
|
|
Delivers full power with minimal derating |
|
|
Operating input voltage range: 18-36 V |
|
|
Fixed frequency switching provides predictable EMI |
|
|
No minimum load requirement |
|
|
Industry standard half-brick pin-out |
|
|
Standard size: 2.39" x 2.49" x 0.51", 60.6 x 63.1 x 13.0 mm |
|
|
Total weight: 4.7 oz (133 g) |
|
|
Flanged baseplate version available |
|
|
On/Off control referenced to input side |
|
|
Remote sense for improved output voltage control |
|
|
Wide output trim range |
|
|
Input under-voltage lockout |
|
|
Input over-voltage shutdown |
|
|
Output current limit and short circuit protection |
|
|
Active back drive current limit |
|
|
Thermal shutdown |
|
|
UL 60950-1:2007/A2:2014 Basic Insulation |
|
|
CAN/CSA C22.2 No. 60950-1:2007/A2:2014 |
|
|
EN 60950-1:2006/A2:2013 |
|
|
RoHS compliant (see last page) |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews