OP-2-24V-3V-S 18-36 V Input, 3.3 V/15 A Output Sixteenth-brick
$0
High efficiency performance up to 89% at full load with no minimum load requirement.
Compact industry-standard sixteenth-brick footprint with integral baseplate for conductive cooling.
Wide 18-36 VDC input voltage range with fixed frequency switching for predictable EMI.
Comprehensive protection suite including input UVLO, output over-voltage, current limit, and short-circuit protection.
Advanced output control featuring remote sense, wide voltage trim range, and active back drive current limiting.
Integrated thermal management with automatic shutdown and optional flanged baseplate configurations.
Full regulatory compliance with UL/CSA/EN 62368-1 safety standards and RoHS directives.
- Description
- Reviews (0)
Description
The OP-2-24V-3V-S Sixteenth-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-2-24V-3V-S |
|
|
OP-2-24V-3V-S 18-36 V Input, 3.3 V/15 A Output Sixteenth-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
5.0 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (enabled) (Typ.) |
70 mA |
|
No-Load Input Current (enabled) (Max.) |
90 mA |
|
Disabled Input Current (Typ.) |
10 mA |
|
Disabled Input Current (Max.) |
14 mA |
|
Response to Input Transient (Typ.) |
0.3 V |
|
Response to Input Transient (Notes & Conditions) |
250 V/ms |
|
Input Terminal Ripple Current (Typ.) |
35 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
20 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting fuse recommended |
|
Output Voltage Set Point (Min.) |
3.267 V |
|
Output Voltage Set Point (Typ.) |
3.300 V |
|
Output Voltage Set Point (Max.) |
3.333 V |
|
Over Line (Typ.) |
+/-0.1 % |
|
Over Line (Max.) |
+/-0.3 % |
|
Over Load (Typ.) |
+/-0.1 % |
|
Over Load (Max.) |
+/-0.3 % |
|
Over Temperature (Min.) |
-50 mV |
|
Over Temperature (Max.) |
50 mV |
|
Total Output Voltage Range (Min.) |
3.217 V |
|
Total Output Voltage Range (Max.) |
3.383 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Output Voltage Ripple and Noise (Notes & Conditions) |
20 MHz bandwidth |
|
Peak-to-Peak (Typ.) |
50 mV |
|
Peak-to-Peak (Max.) |
100 mV |
|
Peak-to-Peak (Notes & Conditions) |
Full load |
|
RMS (Typ.) |
15 mV |
|
RMS (Max.) |
30 mV |
|
RMS (Notes & Conditions) |
Full load |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
15 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current Limit Inception (Min.) |
15.9 A |
|
Output DC Current Limit Inception (Typ.) |
18.7 A |
|
Output DC Current Limit Inception (Max.) |
21.5 A |
|
Output DC Current Limit Inception (Notes & Conditions) |
Output voltage 10 % low |
|
Back-Drive Current Limit while Enabled (Typ.) |
3 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn from output pins |
|
Back-Drive Current Limit while Disabled (Typ.) |
2 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn from output pins |
|
Maximum Output Capacitance (Max.) |
10,000 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Settling Time (Typ.) |
80 us |
|
Settling Time (Notes & Conditions) |
To within 1 % Vout nom |
|
Output Voltage Trim Range (Min.) |
-10 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8 & 4; Common Figures 2-4 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8 & 4 |
|
Output Over-Voltage Protection (Min.) |
3.80 V |
|
Output Over-Voltage Protection (Typ.) |
4.00 V |
|
Output Over-Voltage Protection (Max.) |
4.50 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
100 % Load (Typ.) |
87 % |
|
100 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50 % Load (Typ.) |
88 % |
|
50 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
18 V |
|
Operating Input Voltage Range (Typ.) |
24 V |
|
Operating Input Voltage Range (Max.) |
36 V |
|
Turn-On Voltage Threshold (Min.) |
14.8 V |
|
Turn-On Voltage Threshold (Typ.) |
15.4 V |
|
Turn-On Voltage Threshold (Max.) |
16.0 V |
|
Turn-Off Voltage Threshold (Min.) |
13.7 V |
|
Turn-Off Voltage Threshold (Typ.) |
14.5 V |
|
Turn-Off Voltage Threshold (Max.) |
15.1 V |
|
Lockout Voltage Hysteresis (Typ.) |
0.9 V |
|
Recommended External Input Capacitance (Typ.) |
47 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1-0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
1.0/3.9 uH uF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Non-Operating (Min.) |
-1 V |
|
Non-Operating (Max.) |
50 V |
|
Non-Operating (Notes & Conditions) |
Continuous |
|
Operating (Max.) |
40 V |
|
Operating (Notes & Conditions) |
Continuous |
|
Operating Transient (Max.) |
50 V |
|
Operating Transient (Notes & Conditions) |
100 ms |
|
Input to Output (Max.) |
2250 Vdc |
|
Input to Baseplate (Max.) |
2250 Vdc |
|
Output to Baseplate (Max.) |
2250 Vdc |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-45 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
8 V |
|
Turn-On Time (Typ.) |
40 ms |
|
Turn-On Time (Notes & Conditions) |
Full load, Vout=90% nom. (from enable) |
|
Start-Up Inhibit Time (Min.) |
100 ms |
|
Start-Up Inhibit Time (Typ.) |
120 ms |
|
Start-Up Inhibit Time (Max.) |
150 ms |
|
Start-Up Inhibit Time (Notes & Conditions) |
Figure E |
|
Power-Up Inhibit Time (Typ.) |
15 ms |
|
Power-Up Inhibit Time (Notes & Conditions) |
Figure E |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Typ.) |
30 M Ohm |
|
Isolation Capacitance (input to output) (Notes & Conditions) |
See Note 1 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
PCB Temperature (Max.) |
125 °C |
|
PCB Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Typ.) |
500 kHz |
|
Switching Frequency (Notes & Conditions) |
Isolation stage switching freq. is half this |
|
Off-State Voltage (Min.) |
1.5 V |
|
Off-State Voltage (Max.) |
8 V |
|
On-State Voltage (Min.) |
-2 V |
|
On-State Voltage (Max.) |
1 V |
|
ON/OFF Control (Notes & Conditions) |
Application notes Figures A & B |
|
Pull-Up Voltage (Typ.) |
5 V |
|
Pull-Up Resistance (Typ.) |
82.5 k Ohm |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF per MIL-HDBK-217F (Typ.) |
0.8 106 Hrs. |
|
Calculated MTBF per MIL-HDBK-217F (Notes & Conditions) |
Ground Mobile, 70°C Tb |
|
Step Change in Output Current (0.1 A/us) (Typ.) |
175 mV |
|
Step Change in Output Current (0.1 A/us) (Notes & Conditions) |
50 % to 75 % to 50 % Iout max |
Features |
|
|
High efficiency performance up to 89% at full load with no minimum load requirement. |
|
|
Compact industry-standard sixteenth-brick footprint with integral baseplate for conductive cooling. |
|
|
Wide 18-36 VDC input voltage range with fixed frequency switching for predictable EMI. |
|
|
Comprehensive protection suite including input UVLO, output over-voltage, current limit, and short-circuit protection. |
|
|
Advanced output control featuring remote sense, wide voltage trim range, and active back drive current limiting. |
|
|
Integrated thermal management with automatic shutdown and optional flanged baseplate configurations. |
|
|
Full regulatory compliance with UL/CSA/EN 62368-1 safety standards and RoHS directives. |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews