OP-2-385V-24V-F 180-425 V Input, 24.0 V/25 A Output Full-brick

$0

High operational efficiency (88-92%) at full rated load with minimal power derating.
Wide 180-425 V input voltage range featuring integrated under-voltage lockout and over-voltage shutdown.
Industry-standard full-brick package with fixed-frequency switching for predictable EMI characteristics.
Precise output control via remote sensing, isolated On/Off, and a wide voltage trim range.
Comprehensive circuit protection including short circuit, output over-voltage, active backdrive limiting, and thermal shutdown.
Scalable architecture with optional active current sharing for N+1 redundancy and clock synchronization.
Certified compliance with UL/CSA/EN 60950-1 safety standards, featuring reinforced insulation and RoHS/CE marking.

SKU: OP-2-385V-24V-F Category: converter

Description

The OP-2-385V-24V-F full-brick converter series is composed of next-generation, board-mountable, isolated (REINFORCED INSULATION), fixed switching frequency DC-DC converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.

OP-2-385V-24V-F

OP-2-385V-24V-F 180-425 V Input, 24.0 V/25 A Output Full-brick

 

Property

Value

Maximum Input Current (Max.)

5.1 A

Maximum Input Current (Notes & Conditions)

Vin min; trim up; in current limit

No-Load Input Current (enabled) (Typ.)

37 mA

Disabled Input Current (Typ.)

10.0 mA

Disabled Input Current (Max.)

20.0 mA

Response to Input Transient (Typ.)

0.50 V

Response to Input Transient (Notes & Conditions)

Peak

Input Terminal Ripple Current (Typ.)

350 mA

Input Terminal Ripple Current (Notes & Conditions)

RMS, Full load, 20 MHz bandwidth

Recommended Input Fuse (Max.)

5.0 A

Recommended Input Fuse (Notes & Conditions)

Fast acting fuse recommended

Output Voltage Set Point (Min.)

23.76 V

Output Voltage Set Point (Typ.)

24.00 V

Output Voltage Set Point (Max.)

24.24 V

Over Line (Typ.)

+/-0.1 %

Over Line (Max.)

+/-0.3 %

Over Load (Typ.)

+/-0.1 %

Over Load (Max.)

+/-0.3 %

Over Temperature (Min.)

-250 mV

Over Temperature (Max.)

250 mV

Total Output Voltage Range (Min.)

23.40 V

Total Output Voltage Range (Max.)

24.60 V

Total Output Voltage Range (Notes & Conditions)

Over sample, line, load, temperature & life

Output Voltage Ripple and Noise (Notes & Conditions)

20 MHz bandwidth

Peak-to-Peak (Typ.)

210 mV

Peak-to-Peak (Max.)

419 mV

Peak-to-Peak (Notes & Conditions)

Full load

RMS (Typ.)

48 mV

RMS (Max.)

96 mV

RMS (Notes & Conditions)

Full load

Operating Output Current Range (Min.)

0 A

Operating Output Current Range (Max.)

25.0 A

Operating Output Current Range (Notes & Conditions)

Subject to thermal derating

Operating Output Current Range (Start up) (Min.)

0.25 A

Operating Output Current Range (Start up) (Max.)

25.0 A

Operating Output Current Range (Start up) (Notes & Conditions)

See Application notes

Output DC Current Limit Inception (Min.)

27.5 A

Output DC Current Limit Inception (Typ.)

31.3 A

Output DC Current Limit Inception (Max.)

35.0 A

Output DC Current Limit Inception (Notes & Conditions)

Output voltage 10 % Low

Output DC Current Limit Shutdown Voltage (Typ.)

12.0 V

Back-Drive Current Limit while Enabled (Typ.)

0.2 A

Back-Drive Current Limit while Enabled (Notes & Conditions)

Negative current drawn from output pins

Back-Drive Current Limit while Disabled (Typ.)

4.0 mA

Back-Drive Current Limit while Disabled (Notes & Conditions)

Negative current drawn from output pins

Maximum Output Capacitance (Max.)

5,000 uF

Maximum Output Capacitance (Notes & Conditions)

Vout nominal at full load (resistive load)

Step Change in Output Current (0.1 A/ us) (Typ.)

600 mV

Step Change in Output Current (0.1 A/ us) (Notes & Conditions)

50 % to 75 % to 50 % Iout max

Settling Time (Typ.)

400 us

Settling Time (Notes & Conditions)

To within 1 % Vout nom

Output Voltage Trim Range (Min.)

-20 %

Output Voltage Trim Range (Max.)

10 %

Output Voltage Trim Range (Notes & Conditions)

Across Pins 13 & 18

Output Voltage Remote Sense Range (Max.)

10 %

Output Voltage Remote Sense Range (Notes & Conditions)

Across Pins 13 & 18

Output Over-Voltage Protection (Min.)

27.0 V

Output Over-Voltage Protection (Typ.)

30.0 V

Output Over-Voltage Protection (Max.)

33.0 V

Output Over-Voltage Protection (Notes & Conditions)

Across Pins 13 & 18

Auxiliary power (Min.)

7 V

Auxiliary power (Typ.)

8 V

Auxiliary power (Max.)

10 V

Auxiliary power (Notes & Conditions)

Maximum current of 50 mA, Referenced to Vout(-)

100 % Load (Typ.)

90 %

50 % Load (Typ.)

91 %

Operating Input Voltage Range (Min.)

180 V

Operating Input Voltage Range (Typ.)

385 V

Operating Input Voltage Range (Max.)

425 V

Operating Input Voltage Range (Notes & Conditions)

475 V transient for 1 s

Input Voltage Rise Time (Min.)

500 us

Input Voltage Rise Time (Notes & Conditions)

0 – 425 V

Turn-On Voltage Threshold (Min.)

169.0 V

Turn-On Voltage Threshold (Typ.)

174.0 V

Turn-On Voltage Threshold (Max.)

179.0 V

Turn-Off Voltage Threshold (Min.)

157.0 V

Turn-Off Voltage Threshold (Typ.)

162.0 V

Turn-Off Voltage Threshold (Max.)

167.0 V

Lockout Voltage Hysteresis (Typ.)

12.0 V

Input Over-Voltage Shutdown (Typ.)

500 V

Recommended External Input Capacitance (Typ.)

7 uF

Recommended External Input Capacitance (Notes & Conditions)

Typical ESR 1 Ohm see Note 2

Input Filter Component Values (CLC) (Typ.)

.2725.51.2 uF uH uF

Input Filter Component Values (CLC) (Notes & Conditions)

Internal values

Non-Operating (Min.)

-0.5 V

Non-Operating (Max.)

600 V

Non-Operating (Notes & Conditions)

Continuous

Operating (Max.)

425 V

Operating (Notes & Conditions)

Continuous

Operating Transient (Max.)

475 V

Operating Transient (Notes & Conditions)

1 s transient, square wave

Input to Output (Max.)

4250 Vdc

Input to Output (Notes & Conditions)

Reinforced Insulation

Input to Baseplate (Max.)

2300 Vdc

Input to Baseplate (Notes & Conditions)

Basic Insulation

Output to Baseplate (Max.)

2300 Vdc

Output to Baseplate (Notes & Conditions)

Basic Insulation

Operating Temperature (Min.)

-40 °C

Operating Temperature (Max.)

100 °C

Operating Temperature (Notes & Conditions)

Baseplate temperature

Storage Temperature (Min.)

-45 °C

Storage Temperature (Max.)

125 °C

Voltage at ON/OFF input pin (Min.)

-2 V

Voltage at ON/OFF input pin (Max.)

18 V

Turn-On Time (Typ.)

90 ms

Turn-On Time (Notes & Conditions)

Full load, Vout = 90 % nom. (from enable)

Start-Up Inhibit Time (Min.)

360 ms

Start-Up Inhibit Time (Typ.)

400 ms

Start-Up Inhibit Time (Max.)

440 ms

Start-Up Inhibit Time (Notes & Conditions)

-40 °C to +100 °C

Output Voltage Overshoot (Typ.)

0 %

Output Voltage Overshoot (Notes & Conditions)

Maximum Output Capacitance

Isolation Voltage (dielectric strength) (Max.)

4250 V

Isolation Voltage (dielectric strength) (Notes & Conditions)

See Absolute Maximum Ratings

Isolation Resistance (Typ.)

100 M Ohm

Isolation Resistance (Notes & Conditions)

Per EN 60255-5

Isolation Capacitance (input to output) (Notes & Conditions)

See Note 3

Semiconductor Junction Temperature (Max.)

125 °C

Semiconductor Junction Temperature (Notes & Conditions)

Package rated to 150 °C

PCB Temperature (Max.)

125 °C

PCB Temperature (Notes & Conditions)

UL rated max operating temp 130 °C

Transformer Temperature (Max.)

125 °C

Maximum Baseplate Temperature, Tb (Max.)

100 °C

Switching Frequency (Min.)

350 kHz

Switching Frequency (Typ.)

375 kHz

Switching Frequency (Max.)

400 kHz

Off-State Voltage (Min.)

2.4 V

Off-State Voltage (Max.)

18 V

On-State Voltage (Min.)

-1.0 V

On-State Voltage (Max.)

0.8 V

ON/OFF Control (Notes & Conditions)

Application notes Figures A & B

Input Resistance (Typ.)

3 k Ohm

Over-Temperature Shutdown OTP Trip Point (Typ.)

125 °C

Over-Temperature Shutdown OTP Trip Point (Notes & Conditions)

Average PCB Temperature

Over-Temperature Shutdown Restart Hysteresis (Typ.)

10 °C

Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.)

1.3 10^6 Hrs.

Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions)

Tb = 70 °C

Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.)

1.2 10^6 Hrs.

Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions)

Tb = 70 °C

Field Demonstrated MTBF (Typ.)

TBD 10^6 Hrs.

Field Demonstrated MTBF (Notes & Conditions)

See our website for details

No-Load Input Current (enabled) (Max.)

64 mA

Features

High operational efficiency (88-92%) at full rated load with minimal power derating.

Wide 180-425 V input voltage range featuring integrated under-voltage lockout and over-voltage shutdown.

Industry-standard full-brick package with fixed-frequency switching for predictable EMI characteristics.

Precise output control via remote sensing, isolated On/Off, and a wide voltage trim range.

Comprehensive circuit protection including short circuit, output over-voltage, active backdrive limiting, and thermal shutdown.

Scalable architecture with optional active current sharing for N+1 redundancy and clock synchronization.

Certified compliance with UL/CSA/EN 60950-1 safety standards, featuring reinforced insulation and RoHS/CE marking.

Applications

Industrial and Transportation applications

Reviews

There are no reviews yet.


Be the first to review “OP-2-385V-24V-F 180-425 V Input, 24.0 V/25 A Output Full-brick”