OP-2-385V-24V-Q 180-425V Input, 24V/6.25A Output Quarter-brick
$0
High-efficiency operation (88% at full load) with minimal thermal derating, eliminating the need for an external heatsink.
Wide 180-425V input voltage range with fixed-frequency switching for predictable and simplified EMI management.
Compact, industry-standard Quarter-brick footprint with an available flanged baseplate and no minimum load requirements.
Integrated control features including remote sensing, primary-side On/Off control, and adjustable output voltage trim (-20% to +10%).
Robust protection suite comprising input under-voltage lockout, output over-voltage protection, current limiting, short-circuit protection, and thermal shutdown.
Full compliance with international safety standards including UL/CSA/EN 60950-1, CE Marked, and RoHS certified.
- Description
- Reviews (0)
Description
The OP-2-385V-24V-Q quarter-brick converter series is composed of next-generation, board-mountable, REINFORCED INSULATION, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-2-385V-24V-Q |
|
|
OP-2-385V-24V-Q 180-425V Input, 24V/6.25A Output Quarter-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
1.5 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (Typ.) |
25 mA |
|
No-Load Input Current (Max.) |
37 mA |
|
Disabled Input Current (Typ.) |
5 mA |
|
Disabled Input Current (Max.) |
10 mA |
|
Response to Input Transient (Typ.) |
0.9 V |
|
Response to Input Transient (Notes & Conditions) |
See Figure 6 |
|
Input Terminal Ripple Current (Typ.) |
23 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
3 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting external fuse recommended |
|
Output Voltage Set Point (Min.) |
23.76 V |
|
Output Voltage Set Point (Typ.) |
24.00 V |
|
Output Voltage Set Point (Max.) |
24.24 V |
|
Over Line (Typ.) |
+/-0.1 % |
|
Over Line (Max.) |
+/-0.3 % |
|
Over Load (Typ.) |
+/-0.1 % |
|
Over Load (Max.) |
+/-0.3 % |
|
Over Temperature (Min.) |
-360 mV |
|
Over Temperature (Max.) |
360 mV |
|
Total Output Voltage Range (Min.) |
23.40 V |
|
Total Output Voltage Range (Max.) |
24.60 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Peak-to-Peak (Min.) |
0 mV |
|
Peak-to-Peak (Typ.) |
90 mV |
|
Peak-to-Peak (Max.) |
180 mV |
|
Peak-to-Peak (Notes & Conditions) |
Full load; 20 MHz bandwidth |
|
RMS (Typ.) |
20 mV |
|
RMS (Max.) |
40 mV |
|
RMS (Notes & Conditions) |
Full load; 20 MHz bandwidth |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
6.25 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current-Limit Inception (Min.) |
6.9 A |
|
Output DC Current-Limit Inception (Typ.) |
7.8 A |
|
Output DC Current-Limit Inception (Max.) |
8.8 A |
|
Output DC Current-Limit Inception (Notes & Conditions) |
Output voltage 10% Low |
|
Output DC Current-Limit Shutdown Voltage (Typ.) |
14.5 V |
|
Back-Drive Current Limit while Enabled (Typ.) |
1 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn from output |
|
Back-Drive Current Limit while Disabled (Typ.) |
5 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn from output |
|
Maximum Output Capacitance (Max.) |
1,000 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Step Change in Output Current (0.1 A/us) (Typ.) |
550 mV |
|
Step Change in Output Current (0.1 A/us) (Notes & Conditions) |
50% to 75% to 50% Iout max |
|
Settling Time (Typ.) |
150 us |
|
Settling Time (Notes & Conditions) |
To within 1% Vout nom |
|
Output Voltage Trim Range (Min.) |
-20 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8&4; Common Figures 3-5 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8&4 |
|
Output Over-Voltage Protection (Min.) |
27.6 V |
|
Output Over-Voltage Protection (Typ.) |
30.0 V |
|
Output Over-Voltage Protection (Max.) |
32.9 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
Switching Frequency (Min.) |
485 kHz |
|
Switching Frequency (Typ.) |
550 kHz |
|
Switching Frequency (Max.) |
615 kHz |
|
Switching Frequency (Notes & Conditions) |
Isolation stage switching freq. is half this |
|
100% Load (Typ.) |
86 % |
|
100% Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50% Load (Typ.) |
86 % |
|
50% Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
180 V |
|
Operating Input Voltage Range (Typ.) |
385 V |
|
Operating Input Voltage Range (Max.) |
425 V |
|
Operating Input Voltage Range (Notes & Conditions) |
475V transient for 100 ms |
|
Turn-On Voltage Threshold (Min.) |
171 V |
|
Turn-On Voltage Threshold (Typ.) |
174 V |
|
Turn-On Voltage Threshold (Max.) |
177 V |
|
Turn-Off Voltage Threshold (Min.) |
154 V |
|
Turn-Off Voltage Threshold (Typ.) |
162 V |
|
Turn-Off Voltage Threshold (Max.) |
170 V |
|
Lockout Voltage Hysteresis (Typ.) |
12.0 V |
|
Input Over-Voltage Shutdown (Typ.) |
500 V |
|
Recommended External Input Capacitance (Typ.) |
3.3 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 8 Ohm see Note2 |
|
Input Filter Component Values (LC) (Typ.) |
56 .272 uHuF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Non-Operating (Min.) |
-0.5 V |
|
Non-Operating (Max.) |
600 V |
|
Non-Operating (Notes & Conditions) |
Continuous |
|
Operating (Max.) |
425 V |
|
Operating (Notes & Conditions) |
Continuous |
|
Operating Transient Protection (Max.) |
475 V |
|
Operating Transient Protection (Notes & Conditions) |
100 ms transient, square wave |
|
Input to Output (Max.) |
4250 V dc |
|
Input to Output (Notes & Conditions) |
Reinforced Insulation |
|
Input to Base-Plate (Max.) |
2300 V dc |
|
Input to Base-Plate (Notes & Conditions) |
Basic Insulation |
|
Output to Base-Plate (Max.) |
2300 V dc |
|
Output to Base-Plate (Notes & Conditions) |
Basic Insulation |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-45 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
18 V |
|
Turn-On Time (Typ.) |
42 ms |
|
Turn-On Time (Notes & Conditions) |
Full load, Vout=90% nom. |
|
Start-Up Inhibit Time (Min.) |
180 ms |
|
Start-Up Inhibit Time (Typ.) |
200 ms |
|
Start-Up Inhibit Time (Max.) |
220 ms |
|
Start-Up Inhibit Time (Notes & Conditions) |
-40 °C to +85 °C; Figure E |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Isolation Voltage (dielectric strength) (Max.) |
4250 V dc |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Typ.) |
100 M Ohm |
|
Isolation Resistance (Notes & Conditions) |
Per EN 60255-5 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
Board Temperature (Max.) |
125 °C |
|
Board Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Off-State Voltage (Min.) |
2.4 V |
|
Off-State Voltage (Max.) |
18 V |
|
On-State Voltage (Min.) |
-1 V |
|
On-State Voltage (Max.) |
0.8 V |
|
Pull-Up Voltage (Typ.) |
5 V |
|
Pull-Up Resistance (Typ.) |
68.1 k Ohm |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
1.00 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70°C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
1.10 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70°C |
Features |
|
|
High-efficiency operation (88% at full load) with minimal thermal derating, eliminating the need for an external heatsink. |
|
|
Wide 180-425V input voltage range with fixed-frequency switching for predictable and simplified EMI management. |
|
|
Compact, industry-standard Quarter-brick footprint with an available flanged baseplate and no minimum load requirements. |
|
|
Integrated control features including remote sensing, primary-side On/Off control, and adjustable output voltage trim (-20% to +10%). |
|
|
Robust protection suite comprising input under-voltage lockout, output over-voltage protection, current limiting, short-circuit protection, and thermal shutdown. |
|
|
Full compliance with international safety standards including UL/CSA/EN 60950-1, CE Marked, and RoHS certified. |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews
There are no reviews yet.