OP-2-385V-28V-H 180-425V Input, 28V/10.7A Output Half-brick

$0

High operating efficiency of 82-88% with minimal power derating at full rated load.
Wide 180-425V input voltage range featuring integrated under-voltage and over-voltage protection.
Industry-standard half-brick form factor (2.486″ x 2.386″ x 0.495″) for simplified mechanical integration.
Robust protection suite including current limit, short circuit, over-voltage, thermal shutdown, and active back bias limiting.
Advanced regulation and control with remote sensing, -20%/+10% voltage trimming, and no minimum load requirement.
Predictable EMI performance enabled by a fixed-frequency switching architecture.
Enhanced system functionality featuring optional current sharing, clock synchronization, and start synchronization.

SKU: OP-2-385V-28V-H Category: converter

Description

The OP-2-385V-28V-H half-brick converter series is composed of next-generation, board-mountable, isolated (REINFORCED INSULATION), fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.

OP-2-385V-28V-H

OP-2-385V-28V-H 180-425V Input, 28V/10.7A Output Half-brick

 

Property

Value

Maximum Input Current (Max.)

3.0 A

Maximum Input Current (Notes & Conditions)

Vin min; trim up; in current limit

No-Load Input Current (Typ.)

40 mA

No-Load Input Current (Max.)

60 mA

Disabled Input Current (Typ.)

5.0 mA

Disabled Input Current (Max.)

10.0 mA

Response to Input Transient (Typ.)

1.50 V

Response to Input Transient (Notes & Conditions)

Peak

Input Terminal Ripple Current (Typ.)

50 mA

Input Terminal Ripple Current (Notes & Conditions)

RMS, Full load, 20 MHz bandwidth

Recommended Input Fuse (Max.)

5.0 A

Recommended Input Fuse (Notes & Conditions)

Fast acting external fuse recommended

Output Voltage Set Point (Min.)

27.72 V

Output Voltage Set Point (Typ.)

28.00 V

Output Voltage Set Point (Max.)

28.28 V

Over Line (Typ.)

+/-0.1 %

Over Line (Max.)

+/-0.3 %

Over Load (Typ.)

+/-0.1 %

Over Load (Max.)

+/-0.3 %

Over Temperature (Min.)

-140 mV

Over Temperature (Max.)

140 mV

Total Output Voltage Range (Min.)

27.30 V

Total Output Voltage Range (Max.)

28.70 V

Total Output Voltage Range (Notes & Conditions)

Over sample, line, load, temperature & life

Output Voltage Ripple and Noise (Notes & Conditions)

20 MHz bandwidth

Peak-to-Peak (Typ.)

190 mV

Peak-to-Peak (Max.)

380 mV

Peak-to-Peak (Notes & Conditions)

Full load

RMS (Typ.)

54 mV

RMS (Max.)

108 mV

RMS (Notes & Conditions)

Full load

Operating Output Current Range (Max.)

10.7 A

Operating Output Current Range (Notes & Conditions)

Subject to thermal derating

Output DC Current-Limit Inception (Min.)

11 A

Output DC Current-Limit Inception (Typ.)

13.0 A

Output DC Current-Limit Inception (Max.)

15 A

Output DC Current-Limit Inception (Notes & Conditions)

Output voltage 10% Low

Output DC Current-Limit Shutdown Voltage (Typ.)

16.0 V

Back-Drive Current Limit while Enabled (Typ.)

1.3 A

Back-Drive Current Limit while Enabled (Notes & Conditions)

Negative current drawn from output

Back-Drive Current Limit while Disabled (Typ.)

4.0 mA

Back-Drive Current Limit while Disabled (Notes & Conditions)

Negative current drawn from output

Maximum Output Capacitance (Max.)

3,000 uF

Maximum Output Capacitance (Notes & Conditions)

Vout nominal at full load (resistive load)

Settling Time (Typ.)

250 us

Settling Time (Notes & Conditions)

To within 1% Vout nom

Output Voltage Trim Range (Min.)

-20 %

Output Voltage Trim Range (Max.)

10 %

Output Voltage Trim Range (Notes & Conditions)

Across Pins 8&4; Common Figs 3-5

Output Voltage Remote Sense Range (Max.)

10 %

Output Voltage Remote Sense Range (Notes & Conditions)

Across Pins 8&4

Output Over-Voltage Protection (Min.)

33 V

Output Over-Voltage Protection (Typ.)

35 V

Output Over-Voltage Protection (Max.)

37 V

Output Over-Voltage Protection (Notes & Conditions)

Over full temp range

100% Load (Typ.)

89 %

100% Load (Notes & Conditions)

See Figure 1 for efficiency curve

50% Load (Typ.)

87 %

50% Load (Notes & Conditions)

See Figure 1 for efficiency curve

Operating Input Voltage Range (Min.)

180 V

Operating Input Voltage Range (Typ.)

385 V

Operating Input Voltage Range (Max.)

425 V

Operating Input Voltage Range (Notes & Conditions)

475V transient for 1Sec

Turn-On Voltage Threshold (Min.)

169.0 V

Turn-On Voltage Threshold (Typ.)

174.0 V

Turn-On Voltage Threshold (Max.)

178.0 V

Turn-Off Voltage Threshold (Min.)

154.0 V

Turn-Off Voltage Threshold (Typ.)

162.0 V

Turn-Off Voltage Threshold (Max.)

170.0 V

Lockout Voltage Hysteresis (Typ.)

10.0 V

Input Over-Voltage Shutdown (Typ.)

500 V

Recommended External Input Capacitance (Typ.)

3.3 uF

Recommended External Input Capacitance (Notes & Conditions)

Typical ESR 8 Ohm see Note 2

Input Filter Component Values (LC) (Typ.)

11.41 uHuF

Input Filter Component Values (LC) (Notes & Conditions)

Internal values

Non-Operating (Min.)

-1 V

Non-Operating (Max.)

600 V

Non-Operating (Notes & Conditions)

Continuous

Operating (Max.)

425 V

Operating (Notes & Conditions)

Continuous

Operating Transient Protection (Max.)

475 V

Operating Transient Protection (Notes & Conditions)

1sec transient, square wave

Input to Output (Max.)

4250 V dc

Input to Output (Notes & Conditions)

Reinforced Insulation

Input to Base-Plate (Max.)

2300 V dc

Input to Base-Plate (Notes & Conditions)

Basic Insulation

Output to Base-Plate (Max.)

2300 V dc

Output to Base-Plate (Notes & Conditions)

Basic Insulation

Operating Temperature (Min.)

-40 °C

Operating Temperature (Max.)

100 °C

Operating Temperature (Notes & Conditions)

Baseplate temperature

Storage Temperature (Min.)

-45 °C

Storage Temperature (Max.)

125 °C

Voltage at ON/OFF input pin (Min.)

-2 V

Voltage at ON/OFF input pin (Max.)

18 V

Turn-On Time (Typ.)

42 ms

Turn-On Time (Notes & Conditions)

Full load, Vout=90% nom.

Start-Up Inhibit Time (Min.)

360 ms

Start-Up Inhibit Time (Typ.)

400 ms

Start-Up Inhibit Time (Max.)

440 ms

Start-Up Inhibit Time (Notes & Conditions)

-40 °C to +85 °C; Figure E

Output Voltage Overshoot (Typ.)

0 %

Output Voltage Overshoot (Notes & Conditions)

Maximum Output Capacitance

Isolation Voltage (dielectric strength) (Max.)

4250 V

Isolation Voltage (dielectric strength) (Notes & Conditions)

See Absolute Maximum Ratings

Isolation Resistance (Typ.)

100 M Ohm

Isolation Resistance (Notes & Conditions)

per EN 60255-5

Isolation Capacitance (input to output) (Notes & Conditions)

See Note 3

Semiconductor Junction Temperature (Max.)

125 °C

Semiconductor Junction Temperature (Notes & Conditions)

Package rated to 150 °C

Board Temperature (Max.)

125 °C

Board Temperature (Notes & Conditions)

UL rated max operating temp 130 °C

Transformer Temperature (Max.)

125 °C

Maximum Baseplate Temperature, Tb (Max.)

100 °C

Switching Frequency (Min.)

510 kHz

Switching Frequency (Typ.)

550 kHz

Switching Frequency (Max.)

590 kHz

Switching Frequency (Notes & Conditions)

Isolation stage switching freq. is half this

Clk Sync (Full feature) (Min.)

600 kHz

Clk Sync (Full feature) (Max.)

630 kHz

Clk Sync (Full feature) (Notes & Conditions)

Note 4, Also please see app section

Off-State Voltage (Min.)

2.4 V

Off-State Voltage (Max.)

18 V

On-State Voltage (Min.)

-1.0 V

On-State Voltage (Max.)

0.8 V

ON/OFF Control (Notes & Conditions)

Application notes Figures A & B

Pull-Up Voltage (Typ.)

5 V

Pull-Up Resistance (Typ.)

68 k Ohm

Over-Temperature Shutdown OTP Trip Point (Typ.)

125 °C

Over-Temperature Shutdown OTP Trip Point (Notes & Conditions)

Average PCB Temperature

Over-Temperature Shutdown Restart Hysteresis (Typ.)

10 °C

Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.)

837 10^3 Hrs.

Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions)

Tb = 70°C

Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.)

928 10^3 Hrs.

Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions)

Tb = 70°C

Field Demonstrated MTBF (Units)

10^3 Hrs.

Field Demonstrated MTBF (Notes & Conditions)

See our website for details

Over Temperature (Typ.)

+/-50 mV

Step Change in Output Current (0.1 A/us) (Typ.)

750 mV

Step Change in Output Current (0.1 A/us) (Notes & Conditions)

50% to 75% to 50% Iout max

Operating Output Current Range (Min.)

0 A

Features

High operating efficiency of 82-88% with minimal power derating at full rated load.

Wide 180-425V input voltage range featuring integrated under-voltage and over-voltage protection.

Industry-standard half-brick form factor (2.486" x 2.386" x 0.495") for simplified mechanical integration.

Robust protection suite including current limit, short circuit, over-voltage, thermal shutdown, and active back bias limiting.

Advanced regulation and control with remote sensing, -20%/+10% voltage trimming, and no minimum load requirement.

Predictable EMI performance enabled by a fixed-frequency switching architecture.

Enhanced system functionality featuring optional current sharing, clock synchronization, and start synchronization.

Applications

Industrial and Transportation applications

Reviews

There are no reviews yet.


Be the first to review “OP-2-385V-28V-H 180-425V Input, 28V/10.7A Output Half-brick”