OP-2-385V-3V-Q 180-425V Input, 3.3V/30A Output Quarter-brick

$0

High efficiency (88% at full load) and superior thermal management enabling full power delivery without external heatsinks.
Wide 180-425V input voltage range with adjustable output (-20% to +10%) and remote voltage sensing.
Industry-standard quarter-brick form factor with an available flanged baseplate for versatile mounting.
Comprehensive protection features including input UVLO, output OVP, current limit, short-circuit protection, and thermal shutdown.
Reinforced insulation and full compliance with international safety standards including UL/CSA/EN 60950-1 and CE marking.
Fixed-frequency switching for predictable EMI performance and stable operation with no minimum load requirement.
Integrated control features including input-side referenced On/Off control and active back bias limit.

SKU: OP-2-385V-3V-Q Category: converter

Description

The OP-2-385V-3V-Q quarter-brick converter series is composed of next-generation, board-mountable, REINFORCED INSULATION, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.

OP-2-385V-3V-Q

OP-2-385V-3V-Q 180-425V Input, 3.3V/30A Output Quarter-brick

 

Property

Value

Maximum Input Current (Max.)

1.0 A

Maximum Input Current (Notes & Conditions)

Vin min; trim up; in current limit

No-Load Input Current (Typ.)

20 mA

No-Load Input Current (Max.)

30 mA

Disabled Input Current (Typ.)

5 mA

Disabled Input Current (Max.)

10 mA

Response to Input Transient (Typ.)

0.13 V

Response to Input Transient (Notes & Conditions)

See Figure 6

Input Terminal Ripple Current (Typ.)

20 mA

Input Terminal Ripple Current (Notes & Conditions)

RMS

Recommended Input Fuse (Max.)

3 A

Recommended Input Fuse (Notes & Conditions)

Fast acting external fuse recommended

Output Voltage Set Point (Min.)

3.267 V

Output Voltage Set Point (Typ.)

3.300 V

Output Voltage Set Point (Max.)

3.333 V

Over Line (Typ.)

+/-0.1 %

Over Line (Max.)

+/-0.3 %

Over Load (Typ.)

+/-0.1 %

Over Load (Max.)

+/-0.3 %

Over Temperature (Min.)

-50 mV

Over Temperature (Max.)

50 mV

Total Output Voltage Range (Min.)

3.217 V

Total Output Voltage Range (Max.)

3.383 V

Total Output Voltage Range (Notes & Conditions)

Over sample, line, load, temperature & life

Output Voltage Ripple and Noise (Notes & Conditions)

20 MHz bandwidth

Peak-to-Peak (Min.)

0 mV

Peak-to-Peak (Typ.)

35 mV

Peak-to-Peak (Max.)

70 mV

Peak-to-Peak (Notes & Conditions)

Full load

RMS (Typ.)

10 mV

RMS (Max.)

20 mV

RMS (Notes & Conditions)

Full load

Operating Output Current Range (Min.)

0 A

Operating Output Current Range (Max.)

30 A

Operating Output Current Range (Notes & Conditions)

Subject to thermal derating

Output DC Current-Limit Inception (Min.)

32.0 A

Output DC Current-Limit Inception (Typ.)

37.5 A

Output DC Current-Limit Inception (Max.)

43.0 A

Output DC Current-Limit Inception (Notes & Conditions)

Output voltage 10% Low

Output DC Current-Limit Shutdown Voltage (Typ.)

2.3 V

Back-Drive Current Limit while Enabled (Typ.)

5 A

Back-Drive Current Limit while Enabled (Notes & Conditions)

Negative current drawn from output

Back-Drive Current Limit while Disabled (Typ.)

5 mA

Back-Drive Current Limit while Disabled (Notes & Conditions)

Negative current drawn from output

Maximum Output Capacitance (Max.)

10,000 uF

Maximum Output Capacitance (Notes & Conditions)

Vout nominal at full load (resistive load)

Settling Time (Typ.)

100 us

Settling Time (Notes & Conditions)

To within 1% Vout nom

Output Voltage Trim Range (Min.)

-15 %

Output Voltage Trim Range (Max.)

10 %

Output Voltage Trim Range (Notes & Conditions)

Across Pins 8&4; Common Figures 3-5

Output Voltage Remote Sense Range (Max.)

10 %

Output Voltage Remote Sense Range (Notes & Conditions)

Across Pins 8&4

Output Over-Voltage Protection (Min.)

3.8 V

Output Over-Voltage Protection (Typ.)

4.1 V

Output Over-Voltage Protection (Max.)

4.5 V

Output Over-Voltage Protection (Notes & Conditions)

Over full temp range

Switching Frequency (Min.)

400 kHz

Switching Frequency (Typ.)

450 kHz

Switching Frequency (Max.)

500 kHz

Switching Frequency (Notes & Conditions)

Isolation stage switching freq. is half this

100% Load (Typ.)

86 %

100% Load (Notes & Conditions)

See Figure 1 for efficiency curve

50% Load (Typ.)

83 %

50% Load (Notes & Conditions)

See Figure 1 for efficiency curve

Operating Input Voltage Range (Min.)

180 V

Operating Input Voltage Range (Typ.)

385 V

Operating Input Voltage Range (Max.)

425 V

Operating Input Voltage Range (Notes & Conditions)

475V transient for 100 ms

Turn-On Voltage Threshold (Min.)

171 V

Turn-On Voltage Threshold (Typ.)

174 V

Turn-On Voltage Threshold (Max.)

177 V

Turn-Off Voltage Threshold (Min.)

154 V

Turn-Off Voltage Threshold (Typ.)

162 V

Turn-Off Voltage Threshold (Max.)

170 V

Lockout Voltage Hysteresis (Typ.)

12.0 V

Input Over-Voltage Shutdown (Typ.)

500 V

Recommended External Input Capacitance (Typ.)

3.3 uF

Recommended External Input Capacitance (Notes & Conditions)

Typical ESR 8 Ohm see Note2

Input Filter Component Values (LC) (Typ.)

56.272 uH uF

Input Filter Component Values (LC) (Notes & Conditions)

Internal values

Non-Operating (Min.)

-0.5 V

Non-Operating (Max.)

600 V

Non-Operating (Notes & Conditions)

Continuous

Operating (Max.)

425 V

Operating (Notes & Conditions)

Continuous

Operating Transient Protection (Max.)

475 V

Operating Transient Protection (Notes & Conditions)

100 ms transient, square wave

Input to Output (Max.)

4250 V dc

Input to Output (Notes & Conditions)

Reinforced Insulation

Input to Base-Plate (Max.)

2300 V dc

Input to Base-Plate (Notes & Conditions)

Basic Insulation

Output to Base-Plate (Max.)

2300 V dc

Output to Base-Plate (Notes & Conditions)

Basic Insulation

Operating Temperature (Min.)

-40 °C

Operating Temperature (Max.)

100 °C

Operating Temperature (Notes & Conditions)

Baseplate temperature

Storage Temperature (Min.)

-45 °C

Storage Temperature (Max.)

125 °C

Voltage at ON/OFF input pin (Min.)

-2 V

Voltage at ON/OFF input pin (Max.)

18 V

Turn-On Time (Typ.)

42 ms

Turn-On Time (Notes & Conditions)

Full load, Vout=90% nom.

Start-Up Inhibit Time (Min.)

180 ms

Start-Up Inhibit Time (Typ.)

200 ms

Start-Up Inhibit Time (Max.)

220 ms

Start-Up Inhibit Time (Notes & Conditions)

-40 °C to +85 °C; Figure E

Output Voltage Overshoot (Typ.)

0 %

Output Voltage Overshoot (Notes & Conditions)

Maximum Output Capacitance

Isolation Voltage (dielectric strength) (Max.)

4250 V dc

Isolation Voltage (dielectric strength) (Notes & Conditions)

See Absolute Maximum Ratings

Isolation Resistance (Typ.)

100 M Ohm

Isolation Resistance (Notes & Conditions)

Per EN 60255-5

Semiconductor Junction Temperature (Max.)

125 °C

Semiconductor Junction Temperature (Notes & Conditions)

Package rated to 150 °C

Board Temperature (Max.)

125 °C

Board Temperature (Notes & Conditions)

UL rated max operating temp 130 °C

Transformer Temperature (Max.)

125 °C

Maximum Baseplate Temperature, Tb (Max.)

100 °C

Off-State Voltage (Min.)

2.4 V

Off-State Voltage (Max.)

18 V

On-State Voltage (Min.)

-1 V

On-State Voltage (Max.)

0.8 V

ON/OFF Control (Notes & Conditions)

Application notes Figures A & B

Pull-Up Voltage (Typ.)

5 V

Pull-Up Resistance (Typ.)

68.1 k Ohm

Over-Temperature Shutdown OTP Trip Point (Typ.)

125 °C

Over-Temperature Shutdown OTP Trip Point (Notes & Conditions)

Average PCB Temperature

Over-Temperature Shutdown Restart Hysteresis (Typ.)

10 °C

Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.)

1.00 10^6 Hrs.

Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions)

Tb = 70°C

Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.)

1.10 10^6 Hrs.

Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions)

Tb = 70°C

Step Change in Output Current (0.1 A/ us) (Typ.)

50 mV

Step Change in Output Current (0.1 A/ us) (Notes & Conditions)

50% to 75% to 50% Iout max

Features

High efficiency (88% at full load) and superior thermal management enabling full power delivery without external heatsinks.

Wide 180-425V input voltage range with adjustable output (-20% to +10%) and remote voltage sensing.

Industry-standard quarter-brick form factor with an available flanged baseplate for versatile mounting.

Comprehensive protection features including input UVLO, output OVP, current limit, short-circuit protection, and thermal shutdown.

Reinforced insulation and full compliance with international safety standards including UL/CSA/EN 60950-1 and CE marking.

Fixed-frequency switching for predictable EMI performance and stable operation with no minimum load requirement.

Integrated control features including input-side referenced On/Off control and active back bias limit.

Applications

Industrial and Transportation applications

Reviews

There are no reviews yet.


Be the first to review “OP-2-385V-3V-Q 180-425V Input, 3.3V/30A Output Quarter-brick”