OP-2-48V-3V-S 34-75 V Input, 3.3 V/15 A Output Sixteenth-brick
$0
High 87% full-load efficiency with minimal derating and no heatsink requirement.
Wide 34-75V operating input range with fixed-frequency switching for predictable EMI.
Industry-standard sixteenth-brick footprint with an optional flanged baseplate.
Comprehensive protection suite including input UVLO/OV, short-circuit, and thermal shutdown.
Advanced control features: remote sense, +/-10% output voltage trim, and input-side On/Off control.
Full compliance with UL/CSA/EN 62368-1 safety standards and RoHS directives.
Flexible operation with no minimum load requirement and integrated active back bias limit.
- Description
- Reviews (0)
Description
The OP-2-48V-3V-S Sixteenth-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-2-48V-3V-S |
|
|
OP-2-48V-3V-S 34-75 V Input, 3.3 V/15 A Output Sixteenth-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
2.1 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (Typ.) |
70 mA |
|
No-Load Input Current (Max.) |
90 mA |
|
Disabled Input Current (Typ.) |
10 mA |
|
Disabled Input Current (Max.) |
14 mA |
|
Response to Input Transient (Typ.) |
100 mV |
|
Response to Input Transient (Notes & Conditions) |
See Figure 6 |
|
Input Terminal Ripple Current (Typ.) |
70 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
20 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting external fuse recommended |
|
Output Voltage Set Point (Min.) |
3.267 V |
|
Output Voltage Set Point (Typ.) |
3.300 V |
|
Output Voltage Set Point (Max.) |
3.333 V |
|
Over Line (Typ.) |
+/-0.1 % |
|
Over Line (Max.) |
+/-0.3 % |
|
Over Load (Typ.) |
+/-0.1 % |
|
Over Load (Max.) |
+/-0.3 % |
|
Over Temperature (Min.) |
-50 mV |
|
Over Temperature (Max.) |
50 mV |
|
Total Output Voltage Range (Min.) |
3.217 V |
|
Total Output Voltage Range (Max.) |
3.383 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Output Voltage Ripple and Noise (Notes & Conditions) |
20 MHz bandwidth |
|
Peak-to-Peak (Min.) |
0 mV |
|
Peak-to-Peak (Typ.) |
70 mV |
|
Peak-to-Peak (Max.) |
140 mV |
|
Peak-to-Peak (Notes & Conditions) |
Full load |
|
RMS (Typ.) |
25 mV |
|
RMS (Max.) |
50 mV |
|
RMS (Notes & Conditions) |
Full load |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
15 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current-Limit Inception (Min.) |
16.0 A |
|
Output DC Current-Limit Inception (Typ.) |
19.1 A |
|
Output DC Current-Limit Inception (Max.) |
22.3 A |
|
Output DC Current-Limit Inception (Notes & Conditions) |
Output voltage 20% Low |
|
Output DC Current-Limit Shutdown Voltage (Typ.) |
2.2 V |
|
Back-Drive Current Limit while Enabled (Typ.) |
4 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn from output |
|
Back-Drive Current Limit while Disabled (Typ.) |
5 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn from output |
|
Maximum Output Capacitance (Max.) |
10,000 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Step Change in Output Current (0.1 A/ us) (Typ.) |
100 mV |
|
Step Change in Output Current (0.1 A/ us) (Notes & Conditions) |
50% to 75% to 50% Iout max |
|
Settling Time (Typ.) |
100 us |
|
Settling Time (Notes & Conditions) |
To within 1% Vout nom |
|
Output Voltage Trim Range (Min.) |
-10 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8&4; Common Figures 2-4 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8&4 |
|
Output Over-Voltage Protection (Min.) |
3.9 V |
|
Output Over-Voltage Protection (Typ.) |
4.2 V |
|
Output Over-Voltage Protection (Max.) |
4.5 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
100% Load (Typ.) |
87 % |
|
100% Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50% Load (Typ.) |
87 % |
|
50% Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
34 V |
|
Operating Input Voltage Range (Typ.) |
48 V |
|
Operating Input Voltage Range (Max.) |
75 V |
|
Turn-On Voltage Threshold (Min.) |
31.2 V |
|
Turn-On Voltage Threshold (Typ.) |
32.5 V |
|
Turn-On Voltage Threshold (Max.) |
33.9 V |
|
Turn-Off Voltage Threshold (Min.) |
29.6 V |
|
Turn-Off Voltage Threshold (Typ.) |
31 V |
|
Turn-Off Voltage Threshold (Max.) |
32.2 V |
|
Lockout Voltage Hysteresis (Typ.) |
1.5 V |
|
Input Over-Voltage Shutdown (Typ.) |
– V |
|
Input Over-Voltage Shutdown (Notes & Conditions) |
Not Available |
|
Recommended External Input Capacitance (Typ.) |
100 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1-0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
1/3.94 uH uF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Non-Operating (Max.) |
100 V |
|
Non-Operating (Notes & Conditions) |
Continuous |
|
Operating (Max.) |
75 V |
|
Operating (Notes & Conditions) |
Continuous |
|
Operating Transient Protection (Max.) |
100 V |
|
Isolation Voltage (Notes & Conditions) |
Reinforced insulation |
|
Input to Output (Max.) |
2250 V dc |
|
Input to Baseplate (Max.) |
2250 V dc |
|
Output to Baseplate (Max.) |
2250 V dc |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-55 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
8 V |
|
Turn-On Time (Typ.) |
40 ms |
|
Turn-On Time (Notes & Conditions) |
Full load, Vout=90% nom. |
|
Start-Up Inhibit Time (Min.) |
100 ms |
|
Start-Up Inhibit Time (Typ.) |
120 ms |
|
Start-Up Inhibit Time (Max.) |
150 ms |
|
Start-Up Inhibit Time (Notes & Conditions) |
Figure F |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Typ.) |
30 M Ohm |
|
Isolation Capacitance (input to output) (Notes & Conditions) |
See Note 1 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
Board Temperature (Max.) |
125 °C |
|
Board Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Typ.) |
500 kHz |
|
Switching Frequency (Notes & Conditions) |
Isolation stage switching freq. is half |
|
Off-State Voltage (Min.) |
1.5 V |
|
Off-State Voltage (Max.) |
8 V |
|
On-State Voltage (Min.) |
-2 V |
|
On-State Voltage (Max.) |
1 V |
|
ON/OFF Control (Notes & Conditions) |
Application notes Figures A & B |
|
Pull-Up Voltage (Typ.) |
5 V |
|
Pull-Up Resistance (Typ.) |
82.5 k Ohm |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
3.80 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70 °C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
0.68 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70 °C |
Features |
|
|
High 87% full-load efficiency with minimal derating and no heatsink requirement. |
|
|
Wide 34-75V operating input range with fixed-frequency switching for predictable EMI. |
|
|
Industry-standard sixteenth-brick footprint with an optional flanged baseplate. |
|
|
Comprehensive protection suite including input UVLO/OV, short-circuit, and thermal shutdown. |
|
|
Advanced control features: remote sense, +/-10% output voltage trim, and input-side On/Off control. |
|
|
Full compliance with UL/CSA/EN 62368-1 safety standards and RoHS directives. |
|
|
Flexible operation with no minimum load requirement and integrated active back bias limit. |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews