OP-2-72V-15V-Q 42-110 V Input, 15 V/10 A Output Quarter-brick
$0
High efficiency up to 92% with minimal power derating and no minimum load requirement.
Wide 42-110 V input voltage range with fixed-frequency switching for predictable EMI performance.
Industry-standard quarter-brick footprint available in standard or flanged baseplate configurations.
Comprehensive protection suite including input UVLO, output OVP, current limiting, and thermal shutdown.
Precision output management featuring remote sense, wide voltage trim range, and active back-drive current limiting.
Safety certified to UL/EN 62368-1 standards with CE marking and full RoHS compliance.
- Description
- Reviews (0)
Description
The OP-2-72V-15V-Q quarter-brick converter series is composed of next-generation, board-mountable, isolated (REINFORCED), fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-2-72V-15V-Q |
|
|
OP-2-72V-15V-Q 42-110 V Input, 15 V/10 A Output Quarter-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
5.2 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; Vout nom; in current limit |
|
No-Load Input Current (from enable) (Typ.) |
45 mA |
|
No-Load Input Current (from enable) (Max.) |
60 mA |
|
Disabled Input Current (Typ.) |
2 mA |
|
Disabled Input Current (Max.) |
4 mA |
|
Response to Input Transient (Typ.) |
0.38 V |
|
Input Terminal Ripple Current (Typ.) |
75 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
7 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting fuse recommended |
|
Output Voltage Set Point (Min.) |
14.85 V |
|
Output Voltage Set Point (Typ.) |
15.00 V |
|
Output Voltage Set Point (Max.) |
15.15 V |
|
Total Output Voltage Range (Min.) |
14.62 V |
|
Total Output Voltage Range (Max.) |
15.38 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
10 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current Limit Inception (Min.) |
11.0 A |
|
Output DC Current Limit Inception (Typ.) |
12.0 A |
|
Output DC Current Limit Inception (Max.) |
13.0 A |
|
Output DC Current Limit Inception (Notes & Conditions) |
Output voltage 10% Low |
|
Output DC Current Limit Shutdown Voltage (Typ.) |
5.8 V |
|
Back-Drive Current Limit while Enabled (Typ.) |
0.8 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Back-Drive Current Limit while Disabled (Typ.) |
10 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Maximum Output Capacitance (Max.) |
1,000 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Output Voltage Trim Range (Min.) |
-20 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8 & 4; Common Figures 3-5 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8 & 4 |
|
Output Over-Voltage Protection (Min.) |
17.6 V |
|
Output Over-Voltage Protection (Typ.) |
18.3 V |
|
Output Over-Voltage Protection (Max.) |
19.1 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
100 % Load (Typ.) |
91 % |
|
100 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50 % Load (Typ.) |
92 % |
|
50 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
42 V |
|
Operating Input Voltage Range (Typ.) |
72 V |
|
Operating Input Voltage Range (Max.) |
110 V |
|
Operating Input Voltage Range (Notes & Conditions) |
See Note 1 |
|
Input Over-Voltage Shutdown (Notes & Conditions) |
Not Available |
|
Recommended External Input Capacitance (Typ.) |
100 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1 – 0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
6.81.2 uH uF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-45 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
18 V |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Typ.) |
100 M Ohm |
|
Isolation Capacitance (input to output) (Typ.) |
1000 pF |
|
Isolation Capacitance (input to output) (Notes & Conditions) |
See Note 2 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
PCB Temperature (Max.) |
125 °C |
|
PCB Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Min.) |
230 kHz |
|
Switching Frequency (Typ.) |
250 kHz |
|
Switching Frequency (Max.) |
270 kHz |
|
Switching Frequency (Notes & Conditions) |
Isolation stage switching freq. is half this |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
1.49 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70 °C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
1.31 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70 °C |
|
Response to Input Transient (Notes & Conditions) |
See Figure 6 |
|
Output Voltage Regulation / Over Line (Typ.) |
+/-0.1 % |
|
Output Voltage Regulation / Over Line (Max.) |
+/-0.3 % |
|
Output Voltage Regulation / Over Load (Typ.) |
+/-0.1 % |
|
Output Voltage Regulation / Over Load (Max.) |
+/-0.3 % |
|
Output Voltage Regulation / Over Temperature (Min.) |
-225 mV |
|
Output Voltage Regulation / Over Temperature (Max.) |
225 mV |
|
Output Voltage Ripple and Noise / Peak-to-Peak (Typ.) |
150 mV |
|
Output Voltage Ripple and Noise / Peak-to-Peak (Max.) |
300 mV |
|
Output Voltage Ripple and Noise / Peak-to-Peak (Notes & Conditions) |
Full load; 20 MHz bandwidth |
|
Output Voltage Ripple and Noise / RMS (Typ.) |
30 mV |
|
Output Voltage Ripple and Noise / RMS (Max.) |
60 mV |
|
Output Voltage Ripple and Noise / RMS (Notes & Conditions) |
Full load |
|
Output Voltage during Load Current Transient / Step Change in Output Current (0.2 A/ us) (Typ.) |
640 mV |
|
Output Voltage during Load Current Transient / Step Change in Output Current (0.2 A/ us) (Notes & Conditions) |
50 % to 75 % to 50 % Iout max |
|
Output Voltage during Load Current Transient / Settling Time (Typ.) |
400 us |
|
Output Voltage during Load Current Transient / Settling Time (Notes & Conditions) |
To within 1 % Vout nom |
|
Input Under-Voltage Lockout / Turn-On Voltage Threshold (Min.) |
38.8 V |
|
Input Under-Voltage Lockout / Turn-On Voltage Threshold (Typ.) |
40.3 V |
|
Input Under-Voltage Lockout / Turn-On Voltage Threshold (Max.) |
41.8 V |
|
Input Under-Voltage Lockout / Turn-Off Voltage Threshold (Min.) |
35.2 V |
|
Input Under-Voltage Lockout / Turn-Off Voltage Threshold (Typ.) |
36.8 V |
|
Input Under-Voltage Lockout / Turn-Off Voltage Threshold (Max.) |
38.4 V |
|
Input Under-Voltage Lockout / Lockout Voltage Hysteresis (Typ.) |
3.5 V |
|
Input Voltage / Non-Operating (Min.) |
-1 V |
|
Input Voltage / Non-Operating (Max.) |
120 V |
|
Input Voltage / Non-Operating (Notes & Conditions) |
Continuous |
|
Input Voltage / Operating (Max.) |
110 V |
|
Input Voltage / Operating (Notes & Conditions) |
Continuous |
|
Input Voltage / Operating Transient (Units) |
V |
|
Isolation Voltage / Input to Output (Max.) |
3000 Vdc |
|
Isolation Voltage / Input to Baseplate (Max.) |
3000 Vdc |
|
Isolation Voltage / Output to Baseplate (Max.) |
3000 Vdc |
|
Turn-On Transient / Turn-On Time (Typ.) |
9 ms |
|
Turn-On Transient / Turn-On Time (Notes & Conditions) |
Full load, Vout = 90 % nom. (from enable) |
|
Turn-On Transient / Start-Up Inhibit Time (Min.) |
180 ms |
|
Turn-On Transient / Start-Up Inhibit Time (Typ.) |
200 ms |
|
Turn-On Transient / Start-Up Inhibit Time (Max.) |
220 ms |
|
Turn-On Transient / Start-Up Inhibit Time (Notes & Conditions) |
-40 °C to +125 °C; Figure E |
|
Turn-On Transient / Output Voltage Overshoot (Typ.) |
0 % |
|
Turn-On Transient / Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
ON/OFF Control / Off-State Voltage (Min.) |
2.4 V |
|
ON/OFF Control / Off-State Voltage (Max.) |
18 V |
|
ON/OFF Control / On-State Voltage (Min.) |
-2 V |
|
ON/OFF Control / On-State Voltage (Max.) |
0.8 V |
|
ON/OFF Control / Pull-Up Voltage (Typ.) |
5 V |
|
ON/OFF Control / Pull-Up Voltage (Notes & Conditions) |
Application notes Figures A & B |
|
ON/OFF Control / Pull-Up Resistance (Typ.) |
50 k Ohm |
Features |
|
|
High efficiency up to 92% with minimal power derating and no minimum load requirement. |
|
|
Wide 42-110 V input voltage range with fixed-frequency switching for predictable EMI performance. |
|
|
Industry-standard quarter-brick footprint available in standard or flanged baseplate configurations. |
|
|
Comprehensive protection suite including input UVLO, output OVP, current limiting, and thermal shutdown. |
|
|
Precision output management featuring remote sense, wide voltage trim range, and active back-drive current limiting. |
|
|
Safety certified to UL/EN 62368-1 standards with CE marking and full RoHS compliance. |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews
There are no reviews yet.