OP-4-18V-2V-S 9-36 V Input, 1.8 V/25 A Output Sixteenth-brick
$0
High energy efficiency up to 86% with optimized thermal performance and minimal power derating.
Wide 9-36V input voltage range utilizing fixed-frequency switching for predictable EMI characteristics.
Industry-standard sixteenth-brick form factor with an optional flanged baseplate for versatile mounting.
Advanced control features including remote sensing, wide output trim range, and input-referenced On/Off logic.
Comprehensive integrated protection against over-voltage, under-voltage, short circuits, and thermal excursions.
Robust operational design featuring no minimum load requirement and active back-drive current limiting.
Fully certified to UL/CSA/EN 62368-1 safety standards and RoHS environmental regulations.
- Description
- Reviews (0)
Description
The OP-4-18V-2V-S Sixteenth-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-4-18V-2V-S |
|
|
OP-4-18V-2V-S 9-36 V Input, 1.8 V/25 A Output Sixteenth-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
10 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (enabled) (Typ.) |
120 mA |
|
No-Load Input Current (enabled) (Max.) |
150 mA |
|
Disabled Input Current (Typ.) |
10 mA |
|
Disabled Input Current (Max.) |
15 mA |
|
Response to Input Transient (Typ.) |
0.15 V |
|
Response to Input Transient (Notes & Conditions) |
250 V/ms |
|
Input Terminal Ripple Current (Typ.) |
100 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
20 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting fuse recommended |
|
Output Voltage Set Point (Min.) |
1.782 V |
|
Output Voltage Set Point (Typ.) |
1.800 V |
|
Output Voltage Set Point (Max.) |
1.818 V |
|
Over Line (Typ.) |
+/-0.1 % |
|
Over Line (Max.) |
+/-0.3 % |
|
Over Load (Typ.) |
+/-0.1 % |
|
Over Load (Max.) |
+/-0.3 % |
|
Over Temperature (Min.) |
-27 mV |
|
Over Temperature (Max.) |
27 mV |
|
Total Output Voltage Range (Min.) |
1.755 V |
|
Total Output Voltage Range (Max.) |
1.845 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Output Voltage Ripple and Noise (Notes & Conditions) |
20 MHz bandwidth |
|
Peak-to-Peak (Typ.) |
65 mV |
|
Peak-to-Peak (Max.) |
130 mV |
|
Peak-to-Peak (Notes & Conditions) |
Full load |
|
RMS (Typ.) |
20 mV |
|
RMS (Max.) |
40 mV |
|
RMS (Notes & Conditions) |
Full load |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
25 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current Limit Inception (Min.) |
27.0 A |
|
Output DC Current Limit Inception (Typ.) |
29 A |
|
Output DC Current Limit Inception (Max.) |
41.0 A |
|
Output DC Current Limit Inception (Notes & Conditions) |
Output voltage 10 % Low |
|
Back-Drive Current Limit while Enabled (Typ.) |
1.8 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Back-Drive Current Limit while Disabled (Typ.) |
15 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Maximum Output Capacitance (Max.) |
10,000 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Settling Time (Typ.) |
300 us |
|
Settling Time (Notes & Conditions) |
To within 1 % Vout nom |
|
Output Voltage Trim Range (Min.) |
-10 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8 & 4; Common Figures 2-4 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8 & 4 |
|
Output Over-Voltage Protection (Min.) |
2.1 V |
|
Output Over-Voltage Protection (Typ.) |
2.5 V |
|
Output Over-Voltage Protection (Max.) |
2.9 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
100 % Load (Typ.) |
78.0 % |
|
100 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50 % Load (Typ.) |
83.5 % |
|
50 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
9 V |
|
Operating Input Voltage Range (Typ.) |
18 V |
|
Operating Input Voltage Range (Max.) |
36 V |
|
Turn-On Voltage Threshold (Min.) |
8.5 V |
|
Turn-On Voltage Threshold (Typ.) |
8.8 V |
|
Turn-On Voltage Threshold (Max.) |
9.1 V |
|
Turn-Off Voltage Threshold (Min.) |
8.0 V |
|
Turn-Off Voltage Threshold (Typ.) |
8.3 V |
|
Turn-Off Voltage Threshold (Max.) |
8.6 V |
|
Lockout Voltage Hysteresis (Typ.) |
0.5 V |
|
Recommended External Input Capacitance (Typ.) |
100 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1 – 0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
0.474.4 uHuF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Non-Operating (Min.) |
-1 V |
|
Non-Operating (Max.) |
50 V |
|
Non-Operating (Notes & Conditions) |
Continuous |
|
Operating (Max.) |
36 V |
|
Operating (Notes & Conditions) |
Continuous |
|
Operating Transient (Max.) |
40 V |
|
Operating Transient (Notes & Conditions) |
1 s |
|
Input to Output (Max.) |
2250 Vdc |
|
Input to Baseplate (Max.) |
2250 Vdc |
|
Output to Baseplate (Max.) |
2250 Vdc |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-45 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
8 V |
|
Turn-On Time (Typ.) |
50 ms |
|
Turn-On Time (Notes & Conditions) |
Full load, Vout = 90 % nom. (from enable) |
|
Start-Up Inhibit Time (Min.) |
100 ms |
|
Start-Up Inhibit Time (Typ.) |
120 ms |
|
Start-Up Inhibit Time (Max.) |
150 ms |
|
Start-Up Inhibit Time (Notes & Conditions) |
See App Section Figure E |
|
Power-Up Inhibit Time (Typ.) |
15 ms |
|
Power-Up Inhibit Time (Notes & Conditions) |
See App Section Figure E |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Typ.) |
30 M Ohm |
|
Isolation Capacitance (input to output) (Notes & Conditions) |
See Note 2 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
PCB Temperature (Max.) |
125 °C |
|
PCB Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Typ.) |
500 kHz |
|
Switching Frequency (Notes & Conditions) |
613kHz for 48V |
|
Off-State Voltage (Min.) |
1.4 V |
|
Off-State Voltage (Max.) |
8 V |
|
On-State Voltage (Min.) |
-2 V |
|
On-State Voltage (Max.) |
0.8 V |
|
ON/OFF Control (Notes & Conditions) |
Application notes Figures A & B |
|
Pull-Up Voltage (Typ.) |
5 V |
|
Pull-Up Resistance (Typ.) |
82.5 k Ohm |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
4.2 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70 °C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
0.8 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70 °C |
|
Step Change in Output Current (0.1 A/us) (Typ.) |
150 mV |
|
Step Change in Output Current (0.1 A/us) (Notes & Conditions) |
50 % to 75 % to 50 % Iout max |
Features |
|
|
High energy efficiency up to 86% with optimized thermal performance and minimal power derating. |
|
|
Wide 9-36V input voltage range utilizing fixed-frequency switching for predictable EMI characteristics. |
|
|
Industry-standard sixteenth-brick form factor with an optional flanged baseplate for versatile mounting. |
|
|
Advanced control features including remote sensing, wide output trim range, and input-referenced On/Off logic. |
|
|
Comprehensive integrated protection against over-voltage, under-voltage, short circuits, and thermal excursions. |
|
|
Robust operational design featuring no minimum load requirement and active back-drive current limiting. |
|
|
Fully certified to UL/CSA/EN 62368-1 safety standards and RoHS environmental regulations. |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews
There are no reviews yet.