OP-4-18V-48V-S 9-36 V Input, 48 V/1.04 A Output Sixteenth-brick
$0
High operating efficiency up to 86% with minimal power derating across the rated load.
Versatile 9-36V input range in a compact, industry-standard sixteenth-brick form factor.
Fixed-frequency switching architecture for predictable EMI and stable operation with no minimum load.
Enhanced output control via remote sensing, wide voltage trim range, and input-referenced On/Off logic.
Integrated safety suite including input UVLO/OV, output over-voltage, short circuit, and thermal protection.
Robust mechanical design featuring active back-drive current limiting and an optional flanged baseplate.
Full compliance with UL/CSA/EN 62368-1 safety standards and RoHS environmental regulations.
- Description
- Reviews (0)
Description
The OP-4-18V-48V-S Sixteenth-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-4-18V-48V-S |
|
|
OP-4-18V-48V-S 9-36 V Input, 48 V/1.04 A Output Sixteenth-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
10 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (enabled) (Typ.) |
130 mA |
|
No-Load Input Current (enabled) (Max.) |
180 mA |
|
Disabled Input Current (Typ.) |
10 mA |
|
Disabled Input Current (Max.) |
15 mA |
|
Response to Input Transient (Typ.) |
0.3 V |
|
Response to Input Transient (Notes & Conditions) |
250 V/ms |
|
Input Terminal Ripple Current (Typ.) |
100 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
20 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting fuse recommended |
|
Output Voltage Set Point (Min.) |
47.52 V |
|
Output Voltage Set Point (Typ.) |
48.00 V |
|
Output Voltage Set Point (Max.) |
48.48 V |
|
Total Output Voltage Range (Min.) |
46.80 V |
|
Total Output Voltage Range (Max.) |
49.20 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
1.04 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current Limit Inception (Min.) |
1.12 A |
|
Output DC Current Limit Inception (Typ.) |
1.36 A |
|
Output DC Current Limit Inception (Max.) |
1.60 A |
|
Output DC Current Limit Inception (Notes & Conditions) |
Output voltage 10 % Low |
|
Back-Drive Current Limit while Enabled (Typ.) |
0.5 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Back-Drive Current Limit while Disabled (Typ.) |
20 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Maximum Output Capacitance (Max.) |
100 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Output Voltage Trim Range (Min.) |
-10 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8 & 4; Common Figures 2-4 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8 & 4 |
|
Output Over-Voltage Protection (Min.) |
54 V |
|
Output Over-Voltage Protection (Typ.) |
62 V |
|
Output Over-Voltage Protection (Max.) |
65 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
100 % Load (Typ.) |
84.5 % |
|
100 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50 % Load (Typ.) |
85.5 % |
|
50 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
9 V |
|
Operating Input Voltage Range (Typ.) |
18 V |
|
Operating Input Voltage Range (Max.) |
36 V |
|
Recommended External Input Capacitance (Typ.) |
100 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1 – 0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
0.474.4 uH uF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-45 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
8 V |
|
Turn-On Time (Typ.) |
50 ms |
|
Turn-On Time (Notes & Conditions) |
Full load, Vout = 90 % nom. (from enable) |
|
Start-Up Inhibit Time (Min.) |
100 ms |
|
Start-Up Inhibit Time (Typ.) |
120 ms |
|
Start-Up Inhibit Time (Max.) |
150 ms |
|
Start-Up Inhibit Time (Notes & Conditions) |
See App Section Figure E |
|
Power-Up Inhibit Time (Typ.) |
15 ms |
|
Power-Up Inhibit Time (Notes & Conditions) |
See App Section Figure E |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Typ.) |
30 M Ohm |
|
Isolation Capacitance (input to output) (Notes & Conditions) |
See Note 2 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
PCB Temperature (Max.) |
125 °C |
|
PCB Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Typ.) |
500 kHz |
|
Switching Frequency (Notes & Conditions) |
613kHz for 48V |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
4.2 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70 °C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
0.8 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70 °C |
|
Output Voltage Regulation Over Line (Typ.) |
+/-0.1 % |
|
Output Voltage Regulation Over Line (Max.) |
+/-0.3 % |
|
Output Voltage Regulation Over Load (Typ.) |
+/-0.1 % |
|
Output Voltage Regulation Over Load (Max.) |
+/-0.3 % |
|
Output Voltage Regulation Over Temperature (Min.) |
-720 mV |
|
Output Voltage Regulation Over Temperature (Max.) |
720 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Min.) |
0 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Typ.) |
75 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Max.) |
150 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Notes & Conditions) |
Full load; 20 MHz bandwidth |
|
Output Voltage Ripple and Noise RMS (Typ.) |
20 mV |
|
Output Voltage Ripple and Noise RMS (Max.) |
40 mV |
|
Output Voltage Ripple and Noise RMS (Notes & Conditions) |
Full load |
|
Output Voltage during Load Current Transient Step Change (0.1 A/ us) (Typ.) |
400 mV |
|
Output Voltage during Load Current Transient Step Change (0.1 A/ us) (Notes & Conditions) |
50 % to 75 % to 50 % Iout max |
|
Output Voltage during Load Current Transient Settling Time (Typ.) |
600 us |
|
Output Voltage during Load Current Transient Settling Time (Notes & Conditions) |
To within 1 % Vout nom |
|
Input Under-Voltage Lockout Turn-On Voltage Threshold (Min.) |
8.5 V |
|
Input Under-Voltage Lockout Turn-On Voltage Threshold (Typ.) |
8.8 V |
|
Input Under-Voltage Lockout Turn-On Voltage Threshold (Max.) |
9.1 V |
|
Input Under-Voltage Lockout Turn-Off Voltage Threshold (Min.) |
8.0 V |
|
Input Under-Voltage Lockout Turn-Off Voltage Threshold (Typ.) |
8.3 V |
|
Input Under-Voltage Lockout Turn-Off Voltage Threshold (Max.) |
8.6 V |
|
Input Under-Voltage Lockout Lockout Voltage Hysteresis (Typ.) |
0.5 V |
|
Input Voltage Non-Operating (Min.) |
-1 V |
|
Input Voltage Non-Operating (Max.) |
50 V |
|
Input Voltage Non-Operating (Notes & Conditions) |
Continuous |
|
Input Voltage Operating (Max.) |
36 V |
|
Input Voltage Operating (Notes & Conditions) |
Continuous |
|
Input Voltage Operating Transient (Max.) |
40 V |
|
Input Voltage Operating Transient (Notes & Conditions) |
1 s |
|
Isolation Voltage Input to Output (Max.) |
2250 Vdc |
|
Isolation Voltage Input to Baseplate (Max.) |
2250 Vdc |
|
Isolation Voltage Output to Baseplate (Max.) |
2250 Vdc |
|
ON/OFF Control Off-State Voltage (Min.) |
1.4 V |
|
ON/OFF Control Off-State Voltage (Max.) |
8 V |
|
ON/OFF Control On-State Voltage (Min.) |
-2 V |
|
ON/OFF Control On-State Voltage (Max.) |
0.8 V |
|
ON/OFF Control Pull-Up Voltage (Typ.) |
5 V |
|
ON/OFF Control Pull-Up Voltage (Notes & Conditions) |
Application notes Figures A & B |
|
ON/OFF Control Pull-Up Resistance (Typ.) |
82.5 k Ohm |
Features |
|
|
High operating efficiency up to 86% with minimal power derating across the rated load. |
|
|
Versatile 9-36V input range in a compact, industry-standard sixteenth-brick form factor. |
|
|
Fixed-frequency switching architecture for predictable EMI and stable operation with no minimum load. |
|
|
Enhanced output control via remote sensing, wide voltage trim range, and input-referenced On/Off logic. |
|
|
Integrated safety suite including input UVLO/OV, output over-voltage, short circuit, and thermal protection. |
|
|
Robust mechanical design featuring active back-drive current limiting and an optional flanged baseplate. |
|
|
Full compliance with UL/CSA/EN 62368-1 safety standards and RoHS environmental regulations. |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews
There are no reviews yet.