OP-4-36V-24V-H 18-75 V Input, 24 V/9 A Output Half-brick

$0

High efficiency up to 92% with optimized thermal performance and minimal power derating at full load.
Wide 18-75V input voltage range utilizing fixed-frequency switching for predictable EMI management.
Industry-standard half-brick footprint (2.39″ x 2.49″ x 0.51″) with an optional flanged baseplate for versatile mounting.
Advanced output control featuring remote sensing, wide-range voltage trimming, and no minimum load requirements.
Comprehensive protection suite including input UVLO, output OVP, thermal shutdown, and short-circuit protection.
Fully compliant with UL/CSA/EN 62368-1 (Basic Insulation) safety standards and RoHS directives.
Integrated operational features including active back-drive current limiting and input-referenced On/Off control.

SKU: OP-4-36V-24V-H Category: converter

Description

The OP-4-36V-24V-H half-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.

OP-4-36V-24V-H

OP-4-36V-24V-H 18-75 V Input, 24 V/9 A Output Half-brick

 

Property

Value

Maximum Input Current (Max.)

17.6 A

Maximum Input Current (Notes & Conditions)

Vin min; trim up; in current limit

No-Load Input Current (enabled) (Typ.)

110 mA

No-Load Input Current (enabled) (Max.)

140 mA

Disabled Input Current (Typ.)

2 mA

Disabled Input Current (Max.)

4 mA

Response to Input Transient (Typ.)

1 V

Response to Input Transient (Notes & Conditions)

See Figure 6

Input Terminal Ripple Current (Typ.)

300 mA

Input Terminal Ripple Current (Notes & Conditions)

RMS

Recommended Input Fuse (Max.)

20 A

Recommended Input Fuse (Notes & Conditions)

Fast acting fuse recommended

Output Voltage Set Point (Min.)

23.76 V

Output Voltage Set Point (Typ.)

24.00 V

Output Voltage Set Point (Max.)

24.24 V

Total Output Voltage Range (Min.)

23.40 V

Total Output Voltage Range (Max.)

24.60 V

Total Output Voltage Range (Notes & Conditions)

Over sample, line, load, temperature & life

Operating Output Current Range (Min.)

0 A

Operating Output Current Range (Max.)

9 A

Operating Output Current Range (Notes & Conditions)

Subject to thermal derating

Output DC Current Limit Inception (Min.)

9.9 A

Output DC Current Limit Inception (Typ.)

10.8 A

Output DC Current Limit Inception (Max.)

11.7 A

Output DC Current Limit Inception (Notes & Conditions)

Output voltage 10 % Low

Output DC Current Limit Shutdown Voltage (Typ.)

11 V

Back-Drive Current Limit while Enabled (Typ.)

0.2 A

Back-Drive Current Limit while Enabled (Notes & Conditions)

Negative current drawn into output pins

Back-Drive Current Limit while Disabled (Typ.)

2.5 mA

Back-Drive Current Limit while Disabled (Notes & Conditions)

Negative current drawn into output pins

Maximum Output Capacitance (Max.)

400 uF

Maximum Output Capacitance (Notes & Conditions)

Vout nominal at full load (resistive load)

Output Voltage Trim Range (Min.)

-20 %

Output Voltage Trim Range (Max.)

10 %

Output Voltage Trim Range (Notes & Conditions)

Across Pins 8 & 4; Common Figures 3-5

Output Voltage Remote Sense Range (Max.)

10 %

Output Voltage Remote Sense Range (Notes & Conditions)

Across Pins 8 & 4

Output Over-Voltage Protection (Min.)

28.08 V

Output Over-Voltage Protection (Typ.)

29.28 V

Output Over-Voltage Protection (Max.)

30.48 V

Output Over-Voltage Protection (Notes & Conditions)

Over full temp range

100 % Load (Typ.)

90 %

100 % Load (Notes & Conditions)

See Figure 1 for efficiency curve

50 % Load (Typ.)

93 %

50 % Load (Notes & Conditions)

See Figure 1 for efficiency curve

Operating Input Voltage Range (Min.)

18 V

Operating Input Voltage Range (Typ.)

36 V

Operating Input Voltage Range (Max.)

75 V

Input Over-Voltage Shutdown (Min.)

77 V

Input Over-Voltage Shutdown (Typ.)

80 V

Recommended External Input Capacitance (Typ.)

220 uF

Recommended External Input Capacitance (Notes & Conditions)

Typical ESR 0.1 – 0.2 Ohm

Input Filter Component Values (LC) (Typ.)

1.113.2 uH uF

Input Filter Component Values (LC) (Notes & Conditions)

Internal values

Operating Temperature (Min.)

-40 °C

Operating Temperature (Max.)

100 °C

Operating Temperature (Notes & Conditions)

Baseplate temperature

Storage Temperature (Min.)

-45 °C

Storage Temperature (Max.)

125 °C

Voltage at ON/OFF input pin (Min.)

-2 V

Voltage at ON/OFF input pin (Max.)

18 V

Isolation Voltage (dielectric strength) (Notes & Conditions)

See Absolute Maximum Ratings

Isolation Resistance (Typ.)

30 M Ohm

Isolation Capacitance (input to output) (Typ.)

1000 pF

Isolation Capacitance (input to output) (Notes & Conditions)

See Note 1

Semiconductor Junction Temperature (Max.)

125 °C

Semiconductor Junction Temperature (Notes & Conditions)

Package rated to 150 °C

PCB Temperature (Max.)

125 °C

PCB Temperature (Notes & Conditions)

UL rated max operating temp 130 °C

Transformer Temperature (Max.)

125 °C

Maximum Baseplate Temperature, Tb (Max.)

100 °C

Switching Frequency (Min.)

255 kHz

Switching Frequency (Typ.)

275 kHz

Switching Frequency (Max.)

295 kHz

Switching Frequency (Notes & Conditions)

Isolation stage switching freq. is half this

Over-Temperature Shutdown OTP Trip Point (Typ.)

125 °C

Over-Temperature Shutdown OTP Trip Point (Notes & Conditions)

Average PCB Temperature

Over-Temperature Shutdown Restart Hysteresis (Typ.)

10 °C

Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.)

1.44 10^6 Hrs.

Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions)

Tb = 70 °C

Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.)

1.20 10^6 Hrs.

Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions)

Tb = 70 °C

Output Voltage Regulation Over Line (Typ.)

+/-0.1 %

Output Voltage Regulation Over Line (Max.)

+/-0.3 %

Output Voltage Regulation Over Load (Typ.)

+/-0.1 %

Output Voltage Regulation Over Load (Max.)

+/-0.3 %

Output Voltage Regulation Over Temperature (Min.)

-360 mV

Output Voltage Regulation Over Temperature (Max.)

360 mV

Output Voltage Ripple and Noise Peak-to-Peak (Typ.)

165 mV

Output Voltage Ripple and Noise Peak-to-Peak (Max.)

330 mV

Output Voltage Ripple and Noise Peak-to-Peak (Notes & Conditions)

20 MHz bandwidth

Output Voltage Ripple and Noise RMS (Typ.)

30 mV

Output Voltage Ripple and Noise RMS (Max.)

60 mV

Output Voltage Ripple and Noise RMS (Notes & Conditions)

Full load

Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/ us) (Typ.)

1300 mV

Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/ us) (Notes & Conditions)

50 % to 75 % to 50 % Iout max

Output Voltage during Load Current Transient Settling Time (Typ.)

100 us

Output Voltage during Load Current Transient Settling Time (Notes & Conditions)

To within 1 % Vout nom

Input Under-Voltage Lockout Turn-On Voltage Threshold (Min.)

17.1 V

Input Under-Voltage Lockout Turn-On Voltage Threshold (Typ.)

17.5 V

Input Under-Voltage Lockout Turn-On Voltage Threshold (Max.)

17.9 V

Input Under-Voltage Lockout Turn-Off Voltage Threshold (Min.)

16.1 V

Input Under-Voltage Lockout Turn-Off Voltage Threshold (Typ.)

16.5 V

Input Under-Voltage Lockout Turn-Off Voltage Threshold (Max.)

16.9 V

Input Under-Voltage Lockout Lockout Voltage Hysteresis (Typ.)

1.0 V

Input Voltage Non-Operating (Min.)

-1 V

Input Voltage Non-Operating (Max.)

80 V

Input Voltage Non-Operating (Notes & Conditions)

Continuous

Input Voltage Operating (Max.)

75 V

Input Voltage Operating (Notes & Conditions)

Continuous

Isolation Voltage Input to Output (Max.)

2250 Vdc

Isolation Voltage Input to Baseplate (Max.)

2250 Vdc

Isolation Voltage Output to Baseplate (Max.)

2250 Vdc

Turn-On Transient Turn-On Time (Typ.)

10 ms

Turn-On Transient Turn-On Time (Notes & Conditions)

Full load, Vout = 90 % nom. (from enable)

Turn-On Transient Start-Up Inhibit Time (Min.)

180 ms

Turn-On Transient Start-Up Inhibit Time (Typ.)

200 ms

Turn-On Transient Start-Up Inhibit Time (Max.)

220 ms

Turn-On Transient Start-Up Inhibit Time (Notes & Conditions)

Figure E

Turn-On Transient Output Voltage Overshoot (Typ.)

0 %

Turn-On Transient Output Voltage Overshoot (Notes & Conditions)

Maximum Output Capacitance

ON/OFF Control Off-State Voltage (Min.)

2.4 V

ON/OFF Control Off-State Voltage (Max.)

18 V

ON/OFF Control On-State Voltage (Min.)

-2 V

ON/OFF Control On-State Voltage (Max.)

0.8 V

ON/OFF Control Pull-Up Voltage (Typ.)

5 V

ON/OFF Control Pull-Up Voltage (Notes & Conditions)

Application notes Figures A & B

ON/OFF Control Pull-Up Resistance (Typ.)

50 k Ohm

Features

High efficiency up to 92% with optimized thermal performance and minimal power derating at full load.

Wide 18-75V input voltage range utilizing fixed-frequency switching for predictable EMI management.

Industry-standard half-brick footprint (2.39" x 2.49" x 0.51") with an optional flanged baseplate for versatile mounting.

Advanced output control featuring remote sensing, wide-range voltage trimming, and no minimum load requirements.

Comprehensive protection suite including input UVLO, output OVP, thermal shutdown, and short-circuit protection.

Fully compliant with UL/CSA/EN 62368-1 (Basic Insulation) safety standards and RoHS directives.

Integrated operational features including active back-drive current limiting and input-referenced On/Off control.

Applications

Industrial and Transportation applications

Reviews

There are no reviews yet.


Be the first to review “OP-4-36V-24V-H 18-75 V Input, 24 V/9 A Output Half-brick”