OP-4-36V-24V-H 18-75 V Input, 24 V/9 A Output Half-brick
$0
High efficiency up to 92% with optimized thermal performance and minimal power derating at full load.
Wide 18-75V input voltage range utilizing fixed-frequency switching for predictable EMI management.
Industry-standard half-brick footprint (2.39″ x 2.49″ x 0.51″) with an optional flanged baseplate for versatile mounting.
Advanced output control featuring remote sensing, wide-range voltage trimming, and no minimum load requirements.
Comprehensive protection suite including input UVLO, output OVP, thermal shutdown, and short-circuit protection.
Fully compliant with UL/CSA/EN 62368-1 (Basic Insulation) safety standards and RoHS directives.
Integrated operational features including active back-drive current limiting and input-referenced On/Off control.
- Description
- Reviews (0)
Description
The OP-4-36V-24V-H half-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-4-36V-24V-H |
|
|
OP-4-36V-24V-H 18-75 V Input, 24 V/9 A Output Half-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
17.6 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (enabled) (Typ.) |
110 mA |
|
No-Load Input Current (enabled) (Max.) |
140 mA |
|
Disabled Input Current (Typ.) |
2 mA |
|
Disabled Input Current (Max.) |
4 mA |
|
Response to Input Transient (Typ.) |
1 V |
|
Response to Input Transient (Notes & Conditions) |
See Figure 6 |
|
Input Terminal Ripple Current (Typ.) |
300 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
20 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting fuse recommended |
|
Output Voltage Set Point (Min.) |
23.76 V |
|
Output Voltage Set Point (Typ.) |
24.00 V |
|
Output Voltage Set Point (Max.) |
24.24 V |
|
Total Output Voltage Range (Min.) |
23.40 V |
|
Total Output Voltage Range (Max.) |
24.60 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
9 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current Limit Inception (Min.) |
9.9 A |
|
Output DC Current Limit Inception (Typ.) |
10.8 A |
|
Output DC Current Limit Inception (Max.) |
11.7 A |
|
Output DC Current Limit Inception (Notes & Conditions) |
Output voltage 10 % Low |
|
Output DC Current Limit Shutdown Voltage (Typ.) |
11 V |
|
Back-Drive Current Limit while Enabled (Typ.) |
0.2 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Back-Drive Current Limit while Disabled (Typ.) |
2.5 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Maximum Output Capacitance (Max.) |
400 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Output Voltage Trim Range (Min.) |
-20 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8 & 4; Common Figures 3-5 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8 & 4 |
|
Output Over-Voltage Protection (Min.) |
28.08 V |
|
Output Over-Voltage Protection (Typ.) |
29.28 V |
|
Output Over-Voltage Protection (Max.) |
30.48 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
100 % Load (Typ.) |
90 % |
|
100 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50 % Load (Typ.) |
93 % |
|
50 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
18 V |
|
Operating Input Voltage Range (Typ.) |
36 V |
|
Operating Input Voltage Range (Max.) |
75 V |
|
Input Over-Voltage Shutdown (Min.) |
77 V |
|
Input Over-Voltage Shutdown (Typ.) |
80 V |
|
Recommended External Input Capacitance (Typ.) |
220 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1 – 0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
1.113.2 uH uF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-45 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
18 V |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Typ.) |
30 M Ohm |
|
Isolation Capacitance (input to output) (Typ.) |
1000 pF |
|
Isolation Capacitance (input to output) (Notes & Conditions) |
See Note 1 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
PCB Temperature (Max.) |
125 °C |
|
PCB Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Min.) |
255 kHz |
|
Switching Frequency (Typ.) |
275 kHz |
|
Switching Frequency (Max.) |
295 kHz |
|
Switching Frequency (Notes & Conditions) |
Isolation stage switching freq. is half this |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
1.44 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70 °C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
1.20 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70 °C |
|
Output Voltage Regulation Over Line (Typ.) |
+/-0.1 % |
|
Output Voltage Regulation Over Line (Max.) |
+/-0.3 % |
|
Output Voltage Regulation Over Load (Typ.) |
+/-0.1 % |
|
Output Voltage Regulation Over Load (Max.) |
+/-0.3 % |
|
Output Voltage Regulation Over Temperature (Min.) |
-360 mV |
|
Output Voltage Regulation Over Temperature (Max.) |
360 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Typ.) |
165 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Max.) |
330 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Notes & Conditions) |
20 MHz bandwidth |
|
Output Voltage Ripple and Noise RMS (Typ.) |
30 mV |
|
Output Voltage Ripple and Noise RMS (Max.) |
60 mV |
|
Output Voltage Ripple and Noise RMS (Notes & Conditions) |
Full load |
|
Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/ us) (Typ.) |
1300 mV |
|
Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/ us) (Notes & Conditions) |
50 % to 75 % to 50 % Iout max |
|
Output Voltage during Load Current Transient Settling Time (Typ.) |
100 us |
|
Output Voltage during Load Current Transient Settling Time (Notes & Conditions) |
To within 1 % Vout nom |
|
Input Under-Voltage Lockout Turn-On Voltage Threshold (Min.) |
17.1 V |
|
Input Under-Voltage Lockout Turn-On Voltage Threshold (Typ.) |
17.5 V |
|
Input Under-Voltage Lockout Turn-On Voltage Threshold (Max.) |
17.9 V |
|
Input Under-Voltage Lockout Turn-Off Voltage Threshold (Min.) |
16.1 V |
|
Input Under-Voltage Lockout Turn-Off Voltage Threshold (Typ.) |
16.5 V |
|
Input Under-Voltage Lockout Turn-Off Voltage Threshold (Max.) |
16.9 V |
|
Input Under-Voltage Lockout Lockout Voltage Hysteresis (Typ.) |
1.0 V |
|
Input Voltage Non-Operating (Min.) |
-1 V |
|
Input Voltage Non-Operating (Max.) |
80 V |
|
Input Voltage Non-Operating (Notes & Conditions) |
Continuous |
|
Input Voltage Operating (Max.) |
75 V |
|
Input Voltage Operating (Notes & Conditions) |
Continuous |
|
Isolation Voltage Input to Output (Max.) |
2250 Vdc |
|
Isolation Voltage Input to Baseplate (Max.) |
2250 Vdc |
|
Isolation Voltage Output to Baseplate (Max.) |
2250 Vdc |
|
Turn-On Transient Turn-On Time (Typ.) |
10 ms |
|
Turn-On Transient Turn-On Time (Notes & Conditions) |
Full load, Vout = 90 % nom. (from enable) |
|
Turn-On Transient Start-Up Inhibit Time (Min.) |
180 ms |
|
Turn-On Transient Start-Up Inhibit Time (Typ.) |
200 ms |
|
Turn-On Transient Start-Up Inhibit Time (Max.) |
220 ms |
|
Turn-On Transient Start-Up Inhibit Time (Notes & Conditions) |
Figure E |
|
Turn-On Transient Output Voltage Overshoot (Typ.) |
0 % |
|
Turn-On Transient Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
ON/OFF Control Off-State Voltage (Min.) |
2.4 V |
|
ON/OFF Control Off-State Voltage (Max.) |
18 V |
|
ON/OFF Control On-State Voltage (Min.) |
-2 V |
|
ON/OFF Control On-State Voltage (Max.) |
0.8 V |
|
ON/OFF Control Pull-Up Voltage (Typ.) |
5 V |
|
ON/OFF Control Pull-Up Voltage (Notes & Conditions) |
Application notes Figures A & B |
|
ON/OFF Control Pull-Up Resistance (Typ.) |
50 k Ohm |
Features |
|
|
High efficiency up to 92% with optimized thermal performance and minimal power derating at full load. |
|
|
Wide 18-75V input voltage range utilizing fixed-frequency switching for predictable EMI management. |
|
|
Industry-standard half-brick footprint (2.39" x 2.49" x 0.51") with an optional flanged baseplate for versatile mounting. |
|
|
Advanced output control featuring remote sensing, wide-range voltage trimming, and no minimum load requirements. |
|
|
Comprehensive protection suite including input UVLO, output OVP, thermal shutdown, and short-circuit protection. |
|
|
Fully compliant with UL/CSA/EN 62368-1 (Basic Insulation) safety standards and RoHS directives. |
|
|
Integrated operational features including active back-drive current limiting and input-referenced On/Off control. |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews