OP-4-70V-12V-Q 34-135 V Input, 12 V/11 A Output Quarter-brick

$0

High efficiency up to 91% at full rated load with minimal thermal derating.
Wide input voltage range (34-135 V) with fixed-frequency switching for predictable EMI performance.
Industry-standard quarter-brick footprint available in standard or flanged baseplate configurations.
Advanced control features including remote sense, wide output voltage trim, and zero minimum load requirement.
Fully certified to UL/CSA/EN 60950-1 safety standards, CE marked, and RoHS compliant.
Comprehensive protection suite including input UVLO, output over-voltage, short circuit, and thermal shutdown.

SKU: OP-4-70V-12V-Q Category: converter

Description

The OP-4-70V-12V-Q quarter-brick converter series is composed of next-generation, board-mountable, isolated (REINFORCED), fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.

OP-4-70V-12V-Q

OP-4-70V-12V-Q 34-135 V Input, 12 V/11 A Output Quarter-brick

 

Property

Value

Maximum Input Current (Max.)

5.6 A

Maximum Input Current (Notes & Conditions)

Vin min; trim up; in current limit

No-Load Input Current (enabled) (Typ.)

60 mA

No-Load Input Current (enabled) (Max.)

80 mA

Disabled Input Current (Typ.)

2.5 mA

Disabled Input Current (Max.)

4 mA

Response to Input Transient (Typ.)

0.35 V

Response to Input Transient (Notes & Conditions)

See Figure 6

Input Terminal Ripple Current (Typ.)

360 mA

Input Terminal Ripple Current (Notes & Conditions)

RMS

Recommended Input Fuse (Max.)

10 A

Recommended Input Fuse (Notes & Conditions)

Fast acting fuse recommended

Output Voltage Set Point (Min.)

11.88 V

Output Voltage Set Point (Typ.)

12.00 V

Output Voltage Set Point (Max.)

12.12 V

Over Line (Typ.)

+/-0.1 %

Over Line (Max.)

+/-0.3 %

Over Load (Typ.)

+/-0.1 %

Over Load (Max.)

+/-0.3 %

Over Temperature (Min.)

-180 mV

Over Temperature (Max.)

180 mV

Total Output Voltage Range (Min.)

11.70 V

Total Output Voltage Range (Max.)

12.30 V

Total Output Voltage Range (Notes & Conditions)

Over sample, line, load, temperature & life

Peak-to-Peak (Typ.)

100 mV

Peak-to-Peak (Max.)

200 mV

Peak-to-Peak (Notes & Conditions)

Full load; 20 MHz bandwidth

RMS (Typ.)

30 mV

RMS (Max.)

60 mV

RMS (Notes & Conditions)

Full load

Operating Output Current Range (Min.)

0 A

Operating Output Current Range (Max.)

11 A

Operating Output Current Range (Notes & Conditions)

Subject to thermal derating

Output DC Current Limit Inception (Min.)

12.1 A

Output DC Current Limit Inception (Typ.)

13.2 A

Output DC Current Limit Inception (Max.)

14.3 A

Output DC Current Limit Inception (Notes & Conditions)

Output voltage 10 % Low

Output DC Current Limit Shutdown Voltage (Typ.)

6 V

Back-Drive Current Limit while Enabled (Typ.)

0.42 A

Back-Drive Current Limit while Enabled (Notes & Conditions)

Negative current drawn into output pins

Back-Drive Current Limit while Disabled (Typ.)

1 mA

Back-Drive Current Limit while Disabled (Notes & Conditions)

Negative current drawn into output pins

Maximum Output Capacitance (Max.)

1,500 uF

Maximum Output Capacitance (Notes & Conditions)

Vout nominal at full load (resistive load)

Step Change in Output Current (0.1 A/ us) (Typ.)

360 mV

Step Change in Output Current (0.1 A/ us) (Notes & Conditions)

50 % to 75 % to 50 % Iout max

Settling Time (Typ.)

100 us

Settling Time (Notes & Conditions)

To within 1 % Vout nom

Output Voltage Trim Range (Min.)

-20 %

Output Voltage Trim Range (Max.)

10 %

Output Voltage Trim Range (Notes & Conditions)

Across Pins 8 & 4; Common Figures 3-5

Output Voltage Remote Sense Range (Max.)

10 %

Output Voltage Remote Sense Range (Notes & Conditions)

Across Pins 8 & 4

Output Over-Voltage Protection (Min.)

14.0 V

Output Over-Voltage Protection (Typ.)

14.6 V

Output Over-Voltage Protection (Max.)

15.2 V

Output Over-Voltage Protection (Notes & Conditions)

Over full temp range

100 % Load (Typ.)

91 %

100 % Load (Notes & Conditions)

See Figure 1 for efficiency curve

50 % Load (Typ.)

92 %

50 % Load (Notes & Conditions)

See Figure 1 for efficiency curve

Operating Input Voltage Range (Min.)

34 V

Operating Input Voltage Range (Typ.)

70 V

Operating Input Voltage Range (Max.)

135 V

Turn-On Voltage Threshold (Min.)

32.6 V

Turn-On Voltage Threshold (Typ.)

32.9 V

Turn-On Voltage Threshold (Max.)

33.8 V

Turn-Off Voltage Threshold (Min.)

30.4 V

Turn-Off Voltage Threshold (Typ.)

30.7 V

Turn-Off Voltage Threshold (Max.)

31 V

Lockout Voltage Hysteresis (Typ.)

2.2 V

Recommended External Input Capacitance (Typ.)

100 uF

Recommended External Input Capacitance (Notes & Conditions)

Typical ESR 0.1 – 0.2 Ohm

Input Filter Component Values (LC) (Typ.)

4.71.5 uH uF

Input Filter Component Values (LC) (Notes & Conditions)

Internal values

Non-Operating (Min.)

-1 V

Non-Operating (Max.)

150 V

Non-Operating (Notes & Conditions)

Continuous

Operating (Max.)

135 V

Operating (Notes & Conditions)

Continuous

Operating Transient (Units)

V

Input to Output (Max.)

3000 Vdc

Input to Baseplate (Max.)

3000 Vdc

Output to Baseplate (Max.)

3000 Vdc

Operating Temperature (Min.)

-40 °C

Operating Temperature (Max.)

100 °C

Operating Temperature (Notes & Conditions)

Baseplate temperature

Storage Temperature (Min.)

-45 °C

Storage Temperature (Max.)

125 °C

Voltage at ON/OFF input pin (Min.)

-2 V

Voltage at ON/OFF input pin (Max.)

18 V

Turn-On Time (Typ.)

10 ms

Turn-On Time (Notes & Conditions)

Full load, Vout = 90 % nom. (from enable)

Start-Up Inhibit Time (Min.)

180 ms

Start-Up Inhibit Time (Typ.)

200 ms

Start-Up Inhibit Time (Max.)

220 ms

Start-Up Inhibit Time (Notes & Conditions)

-40 °C to +125 °C; Figure E

Output Voltage Overshoot (Typ.)

0 %

Output Voltage Overshoot (Notes & Conditions)

Maximum Output Capacitance

Isolation Voltage (dielectric strength) (Notes & Conditions)

See Absolute Maximum Ratings

Isolation Resistance (Min.)

100 M Ohm

Isolation Resistance (Notes & Conditions)

500V EN 60255-5

Isolation Capacitance (input to output) (Typ.)

1000 pF

Isolation Capacitance (input to output) (Notes & Conditions)

See Note 1

Semiconductor Junction Temperature (Max.)

125 °C

Semiconductor Junction Temperature (Notes & Conditions)

Package rated to 150 °C

PCB Temperature (Max.)

125 °C

PCB Temperature (Notes & Conditions)

UL rated max operating temp 130 °C

Transformer Temperature (Max.)

125 °C

Maximum Baseplate Temperature, Tb (Max.)

100 °C

Switching Frequency (Min.)

230 kHz

Switching Frequency (Typ.)

250 kHz

Switching Frequency (Max.)

270 kHz

Switching Frequency (Notes & Conditions)

Same for the isolation stage

Off-State Voltage (Min.)

2.4 V

Off-State Voltage (Max.)

18 V

On-State Voltage (Min.)

-2 V

On-State Voltage (Max.)

0.8 V

Pull-Up Voltage (Typ.)

5 V

Pull-Up Resistance (Typ.)

50 k Ohm

Over-Temperature Shutdown OTP Trip Point (Typ.)

125 °C

Over-Temperature Shutdown OTP Trip Point (Notes & Conditions)

Average PCB Temperature

Over-Temperature Shutdown Restart Hysteresis (Typ.)

10 °C

Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.)

1.49 10^6 Hrs.

Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions)

Tb = 70 °C

Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.)

1.31 10^6 Hrs.

Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions)

Tb = 70 °C

Features

High efficiency up to 91% at full rated load with minimal thermal derating.

Wide input voltage range (34-135 V) with fixed-frequency switching for predictable EMI performance.

Industry-standard quarter-brick footprint available in standard or flanged baseplate configurations.

Advanced control features including remote sense, wide output voltage trim, and zero minimum load requirement.

Fully certified to UL/CSA/EN 60950-1 safety standards, CE marked, and RoHS compliant.

Comprehensive protection suite including input UVLO, output over-voltage, short circuit, and thermal shutdown.

Applications

Industrial and Transportation applications

Reviews

There are no reviews yet.


Be the first to review “OP-4-70V-12V-Q 34-135 V Input, 12 V/11 A Output Quarter-brick”