OP-4-90V-7V-Q 34-160 V Input, 7.0 V/17 A Output Quarter-brick
$0
High efficiency up to 92% at full rated load with minimal power derating for optimized thermal management.
Ultra-wide operating input voltage range of 34-160 V suitable for diverse industrial and railway applications.
Predictable EMI performance through fixed-frequency switching in an industry-standard quarter-brick footprint.
Enhanced output control featuring remote sensing, wide voltage trimming, and no minimum load requirement.
Robust physical construction with a lightweight 2.9 oz design and optional flanged baseplate for versatile mounting.
Integrated protection suite including input under-voltage lockout, output over-voltage, thermal shutdown, and short-circuit protection.
Full compliance with international safety and environmental standards including UL/CSA/EN 60950-1, CE, and RoHS.
- Description
- Reviews (0)
Description
The OP-4-90V-7V-Q quarter-brick converter series is composed of next-generation, board-mountable, isolated (REINFORCED), fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-4-90V-7V-Q |
|
|
OP-4-90V-7V-Q 34-160 V Input, 7.0 V/17 A Output Quarter-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
5.1 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (enabled) (Typ.) |
80 mA |
|
No-Load Input Current (enabled) (Max.) |
100 mA |
|
Disabled Input Current (Typ.) |
2 mA |
|
Disabled Input Current (Max.) |
3 mA |
|
Response to Input Transient (Typ.) |
0.12 V |
|
Response to Input Transient (Notes & Conditions) |
500 V/ms |
|
Input Terminal Ripple Current (Typ.) |
300 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
10 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting fuse recommended |
|
Output Voltage Set Point (Min.) |
6.930 V |
|
Output Voltage Set Point (Typ.) |
7.000 V |
|
Output Voltage Set Point (Max.) |
7.070 V |
|
Over Line (Typ.) |
+/-0.1 % |
|
Over Line (Max.) |
+/-0.3 % |
|
Over Load (Typ.) |
+/-0.1 % |
|
Over Load (Max.) |
+/-0.3 % |
|
Total Output Voltage Range (Min.) |
6.825 V |
|
Total Output Voltage Range (Max.) |
7.175 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Output Voltage Ripple and Noise (Notes & Conditions) |
20 MHz bandwidth |
|
Peak-to-Peak (Typ.) |
80 mV |
|
Peak-to-Peak (Max.) |
160 mV |
|
Peak-to-Peak (Notes & Conditions) |
Full load |
|
RMS (Typ.) |
20 mV |
|
RMS (Max.) |
40 mV |
|
RMS (Notes & Conditions) |
Full load |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
17 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current Limit Inception (Min.) |
18.7 A |
|
Output DC Current Limit Inception (Typ.) |
20.4 A |
|
Output DC Current Limit Inception (Max.) |
22.1 A |
|
Output DC Current Limit Inception (Notes & Conditions) |
Output voltage 10 % Low |
|
Output DC Current Limit Shutdown Voltage (Typ.) |
0.9 V |
|
Back-Drive Current Limit while Enabled (Typ.) |
0.8 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Back-Drive Current Limit while Disabled (Typ.) |
10 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn into output pins |
|
Maximum Output Capacitance (Max.) |
8,000 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Step Change in Output Current (0.1 A/ us) (Typ.) |
200 mV |
|
Step Change in Output Current (0.1 A/ us) (Notes & Conditions) |
50 % to 75 % to 50 % Iout max |
|
Settling Time (Typ.) |
400 us |
|
Settling Time (Notes & Conditions) |
To within 1 % Vout nom |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8 & 4 |
|
Output Over-Voltage Protection (Min.) |
8.2 V |
|
Output Over-Voltage Protection (Typ.) |
8.5 V |
|
Output Over-Voltage Protection (Max.) |
8.9 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
100 % Load (Typ.) |
90 % |
|
100 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50 % Load (Typ.) |
92 % |
|
50 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
34 V |
|
Operating Input Voltage Range (Typ.) |
90 V |
|
Operating Input Voltage Range (Max.) |
160 V |
|
Turn-On Voltage Threshold (Min.) |
32.2 V |
|
Turn-On Voltage Threshold (Typ.) |
33.0 V |
|
Turn-On Voltage Threshold (Max.) |
33.8 V |
|
Turn-Off Voltage Threshold (Min.) |
29.3 V |
|
Turn-Off Voltage Threshold (Typ.) |
30.0 V |
|
Turn-Off Voltage Threshold (Max.) |
30.8 V |
|
Lockout Voltage Hysteresis (Typ.) |
3.0 V |
|
Recommended External Input Capacitance (Typ.) |
100 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1-0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
(4.7)1.16 uH uF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Operating (Max.) |
160 V |
|
Operating (Notes & Conditions) |
Continuous |
|
Input to Output (Max.) |
3000 Vdc |
|
Input to Baseplate (Max.) |
3000 Vdc |
|
Output to Baseplate (Max.) |
3000 Vdc |
|
Turn-On Time (Typ.) |
10 ms |
|
Turn-On Time (Notes & Conditions) |
Full load, Vout = 90 % nom. (from enable) |
|
Start-Up Inhibit Time (Min.) |
180 ms |
|
Start-Up Inhibit Time (Typ.) |
200 ms |
|
Start-Up Inhibit Time (Max.) |
220 ms |
|
Start-Up Inhibit Time (Notes & Conditions) |
Figure E |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Min.) |
100 M Ohm |
|
Isolation Resistance (Notes & Conditions) |
500Vdc, Per IEC 60255-5 |
|
Isolation Capacitance (input to output) (Typ.) |
1000 pF |
|
Isolation Capacitance (input to output) (Notes & Conditions) |
See Note 1 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
PCB Temperature (Max.) |
125 °C |
|
PCB Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Typ.) |
250 kHz |
|
Off-State Voltage (Min.) |
2.4 V |
|
Off-State Voltage (Max.) |
8 V |
|
ON/OFF Control (Notes & Conditions) |
Application notes Figures A & B |
|
Pull-Up Voltage (Typ.) |
Vin/6 V |
|
Pull-Up Voltage (Max.) |
15 V |
|
Pull-Up Resistance (Typ.) |
40 k Ohm |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
1.49 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70 °C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
1.31 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70 °C |
|
Over Temperature -105 (Max.) |
105 mV |
|
Output Voltage Trim Range -20 (Max.) |
10 % |
|
Output Voltage Trim Range -20 (Notes & Conditions) |
Across Pins 8 & 4; Common Figures 3-5 |
|
Non-Operating -1 (Max.) |
160 V |
|
Non-Operating -1 (Notes & Conditions) |
Continuous |
|
Operating Temperature -40 (Max.) |
100 °C |
|
Operating Temperature -40 (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature -45 (Max.) |
125 °C |
|
Voltage at ON/OFF input pin -2 (Max.) |
8 V |
|
On-State Voltage -2 (Max.) |
0.8 V |
Features |
|
|
High efficiency up to 92% at full rated load with minimal power derating for optimized thermal management. |
|
|
Ultra-wide operating input voltage range of 34-160 V suitable for diverse industrial and railway applications. |
|
|
Predictable EMI performance through fixed-frequency switching in an industry-standard quarter-brick footprint. |
|
|
Enhanced output control featuring remote sensing, wide voltage trimming, and no minimum load requirement. |
|
|
Robust physical construction with a lightweight 2.9 oz design and optional flanged baseplate for versatile mounting. |
|
|
Integrated protection suite including input under-voltage lockout, output over-voltage, thermal shutdown, and short-circuit protection. |
|
|
Full compliance with international safety and environmental standards including UL/CSA/EN 60950-1, CE, and RoHS. |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews