OP-2-150V-28V-Q 90-210 V Input, 28 V/5.35 A Output Quarter-brick
$0
High operational efficiency up to 91% with optimized thermal performance for minimal power derating.
Industry-standard quarter-brick form factor with optional flanged baseplate for versatile mechanical integration.
Wide 90-210 V input range featuring remote sense and wide-range output voltage trimming for precise control.
Comprehensive protection suite including input UVLO, output OVP, OCP, short circuit, and thermal shutdown.
Reinforced 3000V isolation compliant with global safety standards including UL/CSA/EN 60950-1, CE, and RoHS.
Fixed-frequency switching for predictable EMI management and stable operation with no minimum load requirement.
- Description
- Reviews (0)
Description
The OP-2-150V-28V-Q Quarter-brick converter series is composed of next-generation, board-mountable, REINFORCED INSULATED, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-2-150V-28V-Q |
|
|
OP-2-150V-28V-Q 90-210 V Input, 28 V/5.35 A Output Quarter-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
2.5 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (enabled) (Typ.) |
200 mA |
|
No-Load Input Current (enabled) (Max.) |
250 mA |
|
Disabled Input Current (Typ.) |
4 mA |
|
Disabled Input Current (Max.) |
6 mA |
|
Response to Input Transient (Typ.) |
0.2 V |
|
Response to Input Transient (Notes & Conditions) |
See Figure 6 |
|
Input Terminal Ripple Current (Typ.) |
190 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
3 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting fuse recommended |
|
Output Voltage Set Point (Min.) |
27.72 V |
|
Output Voltage Set Point (Typ.) |
28.00 V |
|
Output Voltage Set Point (Max.) |
28.28 V |
|
Over Line (Typ.) |
+/-0.1 % |
|
Over Line (Max.) |
+/-0.3 % |
|
Over Load (Typ.) |
+/-0.1 % |
|
Over Load (Max.) |
+/-0.3 % |
|
Over Temperature (Min.) |
-420 mV |
|
Over Temperature (Max.) |
420 mV |
|
Total Output Voltage Range (Min.) |
27.30 V |
|
Total Output Voltage Range (Max.) |
28.70 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Output Voltage Ripple and Noise (Notes & Conditions) |
20 MHz bandwidth |
|
Peak-to-Peak (Typ.) |
175 mV |
|
Peak-to-Peak (Max.) |
350 mV |
|
Peak-to-Peak (Notes & Conditions) |
Full load |
|
RMS (Typ.) |
40 mV |
|
RMS (Max.) |
80 mV |
|
RMS (Notes & Conditions) |
Full load |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
5.35 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current Limit Inception (Min.) |
6.10 A |
|
Output DC Current Limit Inception (Typ.) |
6.80 A |
|
Output DC Current Limit Inception (Max.) |
7.50 A |
|
Output DC Current Limit Inception (Notes & Conditions) |
Output voltage 10 % Low |
|
Output DC Current Limit Shutdown Voltage (Typ.) |
22 V |
|
Back-Drive Current Limit while Enabled (Typ.) |
0.3 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn from output pins |
|
Back-Drive Current Limit while Disabled (Typ.) |
15 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn from output pins |
|
Maximum Output Capacitance (Max.) |
500 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Step Change in Output Current (0.1 A/ us) (Typ.) |
600 mV |
|
Step Change in Output Current (0.1 A/ us) (Notes & Conditions) |
50 % to 75 % to 50 % Iout max |
|
Settling Time (Typ.) |
400 us |
|
Settling Time (Notes & Conditions) |
To within 1 % Vout nom |
|
Output Voltage Trim Range (Min.) |
-20 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8 & 4; Common Figures 3-6 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8 & 4 |
|
Output Over-Voltage Protection (Min.) |
32.8 V |
|
Output Over-Voltage Protection (Typ.) |
34.2 V |
|
Output Over-Voltage Protection (Max.) |
35.6 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
100 % Load (Typ.) |
91 % |
|
100 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50 % Load (Typ.) |
90 % |
|
50 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
90 V |
|
Operating Input Voltage Range (Typ.) |
150 V |
|
Operating Input Voltage Range (Max.) |
210 V |
|
Turn-On Voltage Threshold (Min.) |
78.0 V |
|
Turn-On Voltage Threshold (Typ.) |
82.0 V |
|
Turn-On Voltage Threshold (Max.) |
87.0 V |
|
Turn-Off Voltage Threshold (Min.) |
71.0 V |
|
Turn-Off Voltage Threshold (Typ.) |
77 V |
|
Turn-Off Voltage Threshold (Max.) |
83.0 V |
|
Lockout Voltage Hysteresis (Typ.) |
5.0 V |
|
Recommended External Input Capacitance (Typ.) |
8 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 2 Ω |
|
Input Filter Component Values (LC) (Typ.) |
4.71.2 uH uF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Non-Operating (Min.) |
-0.5 V |
|
Non-Operating (Max.) |
250 V |
|
Non-Operating (Notes & Conditions) |
Continuous |
|
Operating (Min.) |
90 V |
|
Operating (Max.) |
210 V |
|
Operating (Notes & Conditions) |
Continuous |
|
Operating Transient (Max.) |
250 V |
|
Isolation Voltage (Notes & Conditions) |
Reinforced insulation |
|
Input to Output (Max.) |
3000 Vdc |
|
Input to Baseplate (Max.) |
3000 Vdc |
|
Output to Baseplate (Max.) |
3000 Vdc |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-45 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
18 V |
|
Turn-On Time (from enable) (Typ.) |
11 ms |
|
Turn-On Time (from enable) (Notes & Conditions) |
Full load, Vout=90 % nom. |
|
Start-Up Inhibit Time (Min.) |
180 ms |
|
Start-Up Inhibit Time (Typ.) |
200 ms |
|
Start-Up Inhibit Time (Max.) |
220 ms |
|
Start-Up Inhibit Time (Notes & Conditions) |
Figure E |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Min.) |
100 MΩ |
|
Isolation Capacitance (input to output) (Typ.) |
1000 pF |
|
Isolation Capacitance (input to output) (Notes & Conditions) |
See Note 1 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
PCB Temperature (Max.) |
125 °C |
|
PCB Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Min.) |
283 kHz |
|
Switching Frequency (Typ.) |
310 kHz |
|
Switching Frequency (Max.) |
337 kHz |
|
Switching Frequency (Notes & Conditions) |
Isolation stage switching freq. is half this |
|
Off-State Voltage (Min.) |
2.4 V |
|
Off-State Voltage (Max.) |
18 V |
|
On-State Voltage (Min.) |
-2 V |
|
On-State Voltage (Max.) |
0.8 V |
|
ON/OFF Control (Notes & Conditions) |
Application notes Figures A & B |
|
Pull-Up Voltage (Typ.) |
5 V |
|
Pull-Up Resistance (Typ.) |
50 kΩ |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
1.44 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70 °C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
1.20 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70 °C |
|
Field Demonstrated MTBF (Units) |
10^6 Hrs. |
|
Field Demonstrated MTBF (Notes & Conditions) |
See our website for details |
Features |
|
|
High operational efficiency up to 91% with optimized thermal performance for minimal power derating. |
|
|
Industry-standard quarter-brick form factor with optional flanged baseplate for versatile mechanical integration. |
|
|
Wide 90-210 V input range featuring remote sense and wide-range output voltage trimming for precise control. |
|
|
Comprehensive protection suite including input UVLO, output OVP, OCP, short circuit, and thermal shutdown. |
|
|
Reinforced 3000V isolation compliant with global safety standards including UL/CSA/EN 60950-1, CE, and RoHS. |
|
|
Fixed-frequency switching for predictable EMI management and stable operation with no minimum load requirement. |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews
There are no reviews yet.