OP-2-150V-48V-Q 90-210 V Input, 48 V/3.125 A Output Quarter-brick

$0

High operating efficiency up to 91% with minimal power derating for optimized thermal performance.
Versatile 90-210V input range with broad output voltage trim and no minimum load requirements.
Industry-standard quarter-brick form factor with optional flanged baseplate for flexible mechanical integration.
Fixed-frequency switching for predictable EMI characteristics and remote sense for precision output control.
Robust safety profile featuring 3000V reinforced isolation and full UL, CSA, EN, CE, and RoHS compliance.
Advanced protection suite including UVLO, OVP, short-circuit, thermal shutdown, and active back-drive current limiting.

SKU: OP-2-150V-48V-Q Category: converter

Description

The OP-2-150V-48V-Q Quarter-brick converter series is composed of next-generation, board-mountable, REINFORCED INSULATED, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.

OP-2-150V-48V-Q

OP-2-150V-48V-Q 90-210 V Input, 48 V/3.125 A Output Quarter-brick

 

Property

Value

Maximum Input Current (Max.)

2.5 A

Maximum Input Current (Notes & Conditions)

Vin min; trim up; in current limit

No-Load Input Current (enabled) (Typ.)

200 mA

No-Load Input Current (enabled) (Max.)

250 mA

Disabled Input Current (Typ.)

4 mA

Disabled Input Current (Max.)

6 mA

Response to Input Transient (Typ.)

0.5 V

Response to Input Transient (Notes & Conditions)

See Figure 6

Input Terminal Ripple Current (Typ.)

370 mA

Input Terminal Ripple Current (Notes & Conditions)

RMS

Recommended Input Fuse (Max.)

3 A

Recommended Input Fuse (Notes & Conditions)

Fast acting fuse recommended

Output Voltage Set Point (Min.)

47.52 V

Output Voltage Set Point (Typ.)

48.00 V

Output Voltage Set Point (Max.)

48.48 V

Over Line (Typ.)

+/-0.1 %

Over Line (Max.)

+/-0.3 %

Over Load (Typ.)

+/-0.1 %

Over Load (Max.)

+/-0.3 %

Over Temperature (Min.)

-720 mV

Over Temperature (Max.)

720 mV

Total Output Voltage Range (Min.)

46.80 V

Total Output Voltage Range (Max.)

49.20 V

Total Output Voltage Range (Notes & Conditions)

Over sample, line, load, temperature & life

Output Voltage Ripple and Noise (Notes & Conditions)

20 MHz bandwidth

Peak-to-Peak (Typ.)

150 mV

Peak-to-Peak (Max.)

300 mV

Peak-to-Peak (Notes & Conditions)

Full load

RMS (Typ.)

20 mV

RMS (Max.)

40 mV

RMS (Notes & Conditions)

Full load

Operating Output Current Range (Min.)

0 A

Operating Output Current Range (Max.)

3.125 A

Operating Output Current Range (Notes & Conditions)

Subject to thermal derating

Output DC Current Limit Inception (Min.)

3.4 A

Output DC Current Limit Inception (Typ.)

3.9 A

Output DC Current Limit Inception (Max.)

4.1 A

Output DC Current Limit Inception (Notes & Conditions)

Output voltage 10 % Low

Output DC Current Limit Shutdown Voltage (Typ.)

35 V

Back-Drive Current Limit while Enabled (Typ.)

0.25 A

Back-Drive Current Limit while Enabled (Notes & Conditions)

Negative current drawn from output pins

Back-Drive Current Limit while Disabled (Typ.)

15 mA

Back-Drive Current Limit while Disabled (Notes & Conditions)

Negative current drawn from output pins

Maximum Output Capacitance (Max.)

250 uF

Maximum Output Capacitance (Notes & Conditions)

Vout nominal at full load (resistive load)

Step Change in Output Current (0.1 A/ us) (Typ.)

850 mV

Step Change in Output Current (0.1 A/ us) (Notes & Conditions)

50 % to 75 % to 50 % Iout max

Settling Time (Typ.)

500 us

Settling Time (Notes & Conditions)

To within 1 % Vout nom

Output Voltage Trim Range (Min.)

-20 %

Output Voltage Trim Range (Max.)

10 %

Output Voltage Trim Range (Notes & Conditions)

Across Pins 8 & 4; Common Figures 3-6

Output Voltage Remote Sense Range (Max.)

10 %

Output Voltage Remote Sense Range (Notes & Conditions)

Across Pins 8 & 4

Output Over-Voltage Protection (Min.)

54.0 V

Output Over-Voltage Protection (Typ.)

60.0 V

Output Over-Voltage Protection (Max.)

66.0 V

Output Over-Voltage Protection (Notes & Conditions)

Over full temp range

100 % Load (Typ.)

90 %

100 % Load (Notes & Conditions)

See Figure 1 for efficiency curve

50 % Load (Typ.)

89 %

50 % Load (Notes & Conditions)

See Figure 1 for efficiency curve

Operating Input Voltage Range (Min.)

90 V

Operating Input Voltage Range (Typ.)

150 V

Operating Input Voltage Range (Max.)

210 V

Turn-On Voltage Threshold (Min.)

78.0 V

Turn-On Voltage Threshold (Typ.)

82.0 V

Turn-On Voltage Threshold (Max.)

87.0 V

Turn-Off Voltage Threshold (Min.)

71.0 V

Turn-Off Voltage Threshold (Typ.)

77 V

Turn-Off Voltage Threshold (Max.)

83.0 V

Lockout Voltage Hysteresis (Typ.)

5.0 V

Recommended External Input Capacitance (Typ.)

8 uF

Recommended External Input Capacitance (Notes & Conditions)

Typical ESR 2 Ohm

Input Filter Component Values (LC) (Typ.)

4.71.2 uH uF

Input Filter Component Values (LC) (Notes & Conditions)

Internal values

Non-Operating (Min.)

-0.5 V

Non-Operating (Max.)

250 V

Non-Operating (Notes & Conditions)

Continuous

Operating (Min.)

90 V

Operating (Max.)

210 V

Operating (Notes & Conditions)

Continuous

Operating Transient (Max.)

250 V

Isolation Voltage (Notes & Conditions)

Reinforced insulation

Input to Output (Max.)

3000 Vdc

Input to Baseplate (Max.)

3000 Vdc

Output to Baseplate (Max.)

3000 Vdc

Operating Temperature (Min.)

-40 °C

Operating Temperature (Max.)

100 °C

Operating Temperature (Notes & Conditions)

Baseplate temperature

Storage Temperature (Min.)

-45 °C

Storage Temperature (Max.)

125 °C

Voltage at ON/OFF input pin (Min.)

-2 V

Voltage at ON/OFF input pin (Max.)

18 V

Turn-On Time (from enable) (Typ.)

11 ms

Turn-On Time (from enable) (Notes & Conditions)

Full load, Vout=90 % nom.

Start-Up Inhibit Time (Min.)

180 ms

Start-Up Inhibit Time (Typ.)

200 ms

Start-Up Inhibit Time (Max.)

220 ms

Start-Up Inhibit Time (Notes & Conditions)

Figure E

Output Voltage Overshoot (Typ.)

0 %

Output Voltage Overshoot (Notes & Conditions)

Maximum Output Capacitance

Isolation Voltage (dielectric strength) (Notes & Conditions)

See Absolute Maximum Ratings

Isolation Resistance (Min.)

100 M Ohm

Isolation Capacitance (input to output) (Typ.)

1000 pF

Isolation Capacitance (input to output) (Notes & Conditions)

See Note 1

Semiconductor Junction Temperature (Max.)

125 °C

Semiconductor Junction Temperature (Notes & Conditions)

Package rated to 150 °C

PCB Temperature (Max.)

125 °C

PCB Temperature (Notes & Conditions)

UL rated max operating temp 130 °C

Transformer Temperature (Max.)

125 °C

Maximum Baseplate Temperature, Tb (Max.)

100 °C

Switching Frequency (Min.)

283 kHz

Switching Frequency (Typ.)

310 kHz

Switching Frequency (Max.)

337 kHz

Switching Frequency (Notes & Conditions)

Isolation stage switching freq. is half this

Off-State Voltage (Min.)

2.4 V

Off-State Voltage (Max.)

18 V

On-State Voltage (Min.)

-2 V

On-State Voltage (Max.)

0.8 V

ON/OFF Control (Notes & Conditions)

Application notes Figures A & B

Pull-Up Voltage (Typ.)

5 V

Pull-Up Resistance (Typ.)

50 k Ohm

Over-Temperature Shutdown OTP Trip Point (Typ.)

125 °C

Over-Temperature Shutdown OTP Trip Point (Notes & Conditions)

Average PCB Temperature

Over-Temperature Shutdown Restart Hysteresis (Typ.)

10 °C

Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.)

1.44 10^6 Hrs.

Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions)

Tb = 70 °C

Field Demonstrated MTBF (Units)

10^6 Hrs.

Field Demonstrated MTBF (Notes & Conditions)

See our website for details

Calculated MTBF (MIL-HDBK-217F (Typ.)

1.20 10^6 Hrs.

Calculated MTBF (MIL-HDBK-217F (Notes & Conditions)

Tb = 70 °C

Features

High operating efficiency up to 91% with minimal power derating for optimized thermal performance.

Versatile 90-210V input range with broad output voltage trim and no minimum load requirements.

Industry-standard quarter-brick form factor with optional flanged baseplate for flexible mechanical integration.

Fixed-frequency switching for predictable EMI characteristics and remote sense for precision output control.

Robust safety profile featuring 3000V reinforced isolation and full UL, CSA, EN, CE, and RoHS compliance.

Advanced protection suite including UVLO, OVP, short-circuit, thermal shutdown, and active back-drive current limiting.

Applications

Industrial and Transportation applications

Reviews

There are no reviews yet.


Be the first to review “OP-2-150V-48V-Q 90-210 V Input, 48 V/3.125 A Output Quarter-brick”