OP-2-24V-24V-Q 18-36 V Input, 24 V/5 A Output Quarter-brick

$0

High efficiency up to 93% at full rated load with minimal thermal derating.
Wide 18-36 V input voltage range with fixed-frequency switching for predictable EMI performance.
Industry-standard quarter-brick footprint with optional flanged baseplate for flexible mechanical integration.
Advanced control features including remote sense, wide output trim range, and input-referenced On/Off control.
Comprehensive protection suite including input under-voltage lockout, output over-voltage, current limit, and thermal shutdown.
Certified to UL/EN 62368-1 safety standards and fully RoHS compliant.
Stable operation with no minimum load requirement and active back-drive current limiting.

SKU: OP-2-24V-24V-Q Category: converter

Description

The OP-2-24V-24V-Q quarter-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.

OP-2-24V-24V-Q

OP-2-24V-24V-Q 18-36 V Input, 24 V/5 A Output Quarter-brick

 

Property

Value

Maximum Input Current (Max.)

9.6 A

Maximum Input Current (Notes & Conditions)

Vin min; trim up; in current limit

No-Load Input Current (enabled) (Typ.)

100 mA

No-Load Input Current (enabled) (Max.)

130 mA

Disabled Input Current (Typ.)

2 mA

Disabled Input Current (Max.)

4 mA

Response to Input Transient (Typ.)

0.6 V

Response to Input Transient (Notes & Conditions)

See Figure 6

Input Terminal Ripple Current (Typ.)

200 mA

Input Terminal Ripple Current (Notes & Conditions)

RMS

Recommended Input Fuse (Max.)

20 A

Recommended Input Fuse (Notes & Conditions)

Fast acting fuse recommended

Output Voltage Set Point (Min.)

23.76 V

Output Voltage Set Point (Typ.)

24.00 V

Output Voltage Set Point (Max.)

24.24 V

Total Output Voltage Range (Min.)

23.40 V

Total Output Voltage Range (Max.)

24.60 V

Total Output Voltage Range (Notes & Conditions)

Over sample, line, load, temperature & life

Operating Output Current Range (Min.)

0 A

Operating Output Current Range (Max.)

5 A

Operating Output Current Range (Notes & Conditions)

Subject to thermal derating

Output DC Current Limit Inception (Min.)

5.5 A

Output DC Current Limit Inception (Typ.)

6.0 A

Output DC Current Limit Inception (Max.)

6.5 A

Output DC Current Limit Inception (Notes & Conditions)

Output voltage 10% Low

Output DC Current Limit Shutdown Voltage (Typ.)

12 V

Back-Drive Current Limit while Enabled (Typ.)

0.12 A

Back-Drive Current Limit while Enabled (Notes & Conditions)

Negative current drawn from output pins

Back-Drive Current Limit while Disabled (Typ.)

15 mA

Back-Drive Current Limit while Disabled (Notes & Conditions)

Negative current drawn from output pins

Maximum Output Capacitance (Max.)

400 μF

Maximum Output Capacitance (Notes & Conditions)

Vout nominal at full load (resistive load)

Output Voltage Trim Range (Min.)

-20 %

Output Voltage Trim Range (Max.)

10 %

Output Voltage Trim Range (Notes & Conditions)

Across Pins 8 & 4; Common Figures 3-5

Output Voltage Remote Sense Range (Max.)

10 %

Output Voltage Remote Sense Range (Notes & Conditions)

Across Pins 8 & 4

Output Over-Voltage Protection (Min.)

27.2 V

Output Over-Voltage Protection (Typ.)

29.3 V

Output Over-Voltage Protection (Max.)

31.3 V

Output Over-Voltage Protection (Notes & Conditions)

Over full temp range

100% Load (Typ.)

92 %

100% Load (Notes & Conditions)

See Figure 1 for efficiency curve

50% Load (Typ.)

92 %

50% Load (Notes & Conditions)

See Figure 1 for efficiency curve

Operating Input Voltage Range (Min.)

18 V

Operating Input Voltage Range (Typ.)

24 V

Operating Input Voltage Range (Max.)

36 V

Input Over-Voltage Shutdown (Notes & Conditions)

Not Available

Recommended External Input Capacitance (Typ.)

100.0 μF

Recommended External Input Capacitance (Notes & Conditions)

Typical ESR 0.1-0.2 Ohm

Input Filter Component Values (LC) (Typ.)

1.06.6 μHμF

Input Filter Component Values (LC) (Notes & Conditions)

Internal values

Operating Temperature (Min.)

-40 °C

Operating Temperature (Max.)

100 °C

Operating Temperature (Notes & Conditions)

Baseplate temperature

Storage Temperature (Min.)

-45 °C

Storage Temperature (Max.)

125 °C

Voltage at ON/OFF input pin (Min.)

-2 V

Voltage at ON/OFF input pin (Max.)

18 V

Turn-On Time (Typ.)

9 ms

Turn-On Time (Notes & Conditions)

Full load, Vout = 90% nom. (from enable)

Start-Up Inhibit Time (Min.)

180 ms

Start-Up Inhibit Time (Typ.)

200 ms

Start-Up Inhibit Time (Max.)

220 ms

Start-Up Inhibit Time (Notes & Conditions)

Figure E

Output Voltage Overshoot (Typ.)

0 %

Output Voltage Overshoot (Notes & Conditions)

Maximum Output Capacitance

Isolation Resistance (Min.)

30 M Ohm

Isolation Capacitance (input to output) (Typ.)

1000 pF

Isolation Capacitance (input to output) (Notes & Conditions)

See Note 1

Semiconductor Junction Temperature (Max.)

125 °C

Semiconductor Junction Temperature (Notes & Conditions)

Package rated to 150 °C

PCB Temperature (Max.)

125 °C

PCB Temperature (Notes & Conditions)

UL rated max operating temp 130 °C

Transformer Temperature (Max.)

125 °C

Maximum Baseplate Temperature, Tb (Max.)

100 °C

Switching Frequency (Min.)

230 kHz

Switching Frequency (Typ.)

250 kHz

Switching Frequency (Max.)

270 kHz

Switching Frequency (Notes & Conditions)

Isolation stage switching freq. is the same

Over-Temperature Shutdown OTP Trip Point (Typ.)

125 °C

Over-Temperature Shutdown OTP Trip Point (Notes & Conditions)

Average PCB Temperature

Over-Temperature Shutdown Restart Hysteresis (Typ.)

10 °C

Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.)

1.49 10^6 Hrs.

Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions)

Tb = 70 °C

Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.)

1.31 10^6 Hrs.

Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions)

Tb = 70 °C

Output Voltage Regulation Over Line (Typ.)

+/-0.1 %

Output Voltage Regulation Over Line (Max.)

+/-0.3 %

Output Voltage Regulation Over Load (Typ.)

+/-0.1 %

Output Voltage Regulation Over Load (Max.)

+/-0.3 %

Output Voltage Regulation Over Temperature (Min.)

-360 mV

Output Voltage Regulation Over Temperature (Max.)

360 mV

Output Voltage Ripple and Noise Peak-to-Peak (Typ.)

45 mV

Output Voltage Ripple and Noise Peak-to-Peak (Max.)

90 mV

Output Voltage Ripple and Noise Peak-to-Peak (Notes & Conditions)

20 MHz bandwidth

Output Voltage Ripple and Noise RMS (Typ.)

10 mV

Output Voltage Ripple and Noise RMS (Max.)

20 mV

Output Voltage Ripple and Noise RMS (Notes & Conditions)

Full load

Output Voltage during Load Current Transient Step Change in Output Current (0.8 A/μs) (Typ.)

1300 mV

Output Voltage during Load Current Transient Step Change in Output Current (0.8 A/μs) (Notes & Conditions)

50% to 75% to 50% Iout max

Output Voltage during Load Current Transient Settling Time (Typ.)

50 μs

Output Voltage during Load Current Transient Settling Time (Notes & Conditions)

To within 1% Vout nom

Input Under-Voltage Lockout Turn-On Voltage Threshold (Min.)

17.1 V

Input Under-Voltage Lockout Turn-On Voltage Threshold (Typ.)

17.5 V

Input Under-Voltage Lockout Turn-On Voltage Threshold (Max.)

17.9 V

Input Under-Voltage Lockout Turn-Off Voltage Threshold (Min.)

16.0 V

Input Under-Voltage Lockout Turn-Off Voltage Threshold (Typ.)

16.5 V

Input Under-Voltage Lockout Turn-Off Voltage Threshold (Max.)

16.9 V

Input Under-Voltage Lockout Lockout Hysteresis (Typ.)

1.0 V

Input Voltage Non-Operating (Min.)

-1 V

Input Voltage Non-Operating (Max.)

60 V

Input Voltage Non-Operating (Notes & Conditions)

Continuous

Input Voltage Operating (Max.)

36 V

Input Voltage Operating (Notes & Conditions)

Continuous

Input Voltage Operating Transient Protection (Max.)

50 V

Input Voltage Operating Transient Protection (Notes & Conditions)

1 s transient

Isolation Voltage Input to Output (Max.)

2250 Vdc

Isolation Voltage Input to Baseplate (Max.)

2250 Vdc

Isolation Voltage Output to Baseplate (Max.)

2250 Vdc

ON/OFF Control Off-State Voltage (Min.)

2.4 V

ON/OFF Control Off-State Voltage (Max.)

18 V

ON/OFF Control On-State Voltage (Min.)

-2 V

ON/OFF Control On-State Voltage (Max.)

0.8 V

ON/OFF Control Pull-Up Voltage (Typ.)

5 V

ON/OFF Control Pull-Up Voltage (Notes & Conditions)

Application notes Figures A & B

ON/OFF Control Pull-Up Resistance (Typ.)

50 k Ohm

Features

High efficiency up to 93% at full rated load with minimal thermal derating.

Wide 18-36 V input voltage range with fixed-frequency switching for predictable EMI performance.

Industry-standard quarter-brick footprint with optional flanged baseplate for flexible mechanical integration.

Advanced control features including remote sense, wide output trim range, and input-referenced On/Off control.

Comprehensive protection suite including input under-voltage lockout, output over-voltage, current limit, and thermal shutdown.

Certified to UL/EN 62368-1 safety standards and fully RoHS compliant.

Stable operation with no minimum load requirement and active back-drive current limiting.

Applications

Industrial and Transportation applications

Reviews

There are no reviews yet.


Be the first to review “OP-2-24V-24V-Q 18-36 V Input, 24 V/5 A Output Quarter-brick”