OP-2-24V-24V-S 18-36 V Input, 24.0 V/2.1 A Output Sixteenth-brick
$0
High efficiency up to 89% with integral baseplate for optimized conductive cooling performance.
Wide 18-36 V input range featuring fixed-frequency switching for predictable EMI management.
Industry-standard sixteenth-brick footprint available in standard and flanged baseplate configurations.
Advanced control suite including remote sense, wide output voltage trim, and input-referenced On/Off.
Robust protection circuitry including input UVLO, output current limiting, short circuit, OVP, and thermal shutdown.
Certified safety compliance to UL/CSA/EN 62368-1 standards and full RoHS environmental compliance.
Enhanced operational flexibility with no minimum load requirements and active back-drive current limiting.
- Description
- Reviews (0)
Description
The OP-2-24V-24V-S Sixteenth-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-2-24V-24V-S |
|
|
OP-2-24V-24V-S 18-36 V Input, 24.0 V/2.1 A Output Sixteenth-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
5.0 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (enabled) (Typ.) |
100 mA |
|
No-Load Input Current (enabled) (Max.) |
130 mA |
|
Disabled Input Current (Typ.) |
10 mA |
|
Disabled Input Current (Max.) |
14 mA |
|
Response to Input Transient (Typ.) |
0.5 V |
|
Response to Input Transient (Notes & Conditions) |
250 V/ms |
|
Input Terminal Ripple Current (Typ.) |
35 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
20 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting fuse recommended |
|
Output Voltage Set Point (Min.) |
23.760 V |
|
Output Voltage Set Point (Typ.) |
24.000 V |
|
Output Voltage Set Point (Max.) |
24.240 V |
|
Over Line (Typ.) |
+/-0.1 % |
|
Over Line (Max.) |
+/-0.3 % |
|
Over Load (Typ.) |
+/-0.1 % |
|
Over Load (Max.) |
+/-0.3 % |
|
Over Temperature (Min.) |
-360 mV |
|
Over Temperature (Max.) |
360 mV |
|
Total Output Voltage Range (Min.) |
23.400 V |
|
Total Output Voltage Range (Max.) |
24.600 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Output Voltage Ripple and Noise (Notes & Conditions) |
20 MHz bandwidth |
|
Peak-to-Peak (Typ.) |
75 mV |
|
Peak-to-Peak (Max.) |
150 mV |
|
Peak-to-Peak (Notes & Conditions) |
Full load |
|
RMS (Typ.) |
15 mV |
|
RMS (Max.) |
30 mV |
|
RMS (Notes & Conditions) |
Full load |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
2.1 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current Limit Inception (Min.) |
2.2 A |
|
Output DC Current Limit Inception (Typ.) |
2.7 A |
|
Output DC Current Limit Inception (Max.) |
3.2 A |
|
Output DC Current Limit Inception (Notes & Conditions) |
Output voltage 10 % low |
|
Back-Drive Current Limit while Enabled (Typ.) |
0.5 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn from output pins |
|
Back-Drive Current Limit while Disabled (Typ.) |
2 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn from output pins |
|
Maximum Output Capacitance (Max.) |
700 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Step Change in Output Current (0.1 A/ us) (Typ.) |
400 mV |
|
Step Change in Output Current (0.1 A/ us) (Notes & Conditions) |
50 % to 75 % to 50 % Iout max |
|
Settling Time (Typ.) |
400 us |
|
Settling Time (Notes & Conditions) |
To within 1 % Vout nom |
|
Output Voltage Trim Range (Min.) |
-10 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8 & 4; Common Figures 2-4 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8 & 4 |
|
Output Over-Voltage Protection (Min.) |
26.80 V |
|
Output Over-Voltage Protection (Typ.) |
28.60 V |
|
Output Over-Voltage Protection (Max.) |
32.00 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
100 % Load (Typ.) |
86 % |
|
100 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50 % Load (Typ.) |
86 % |
|
50 % Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
18 V |
|
Operating Input Voltage Range (Typ.) |
24 V |
|
Operating Input Voltage Range (Max.) |
36 V |
|
Turn-On Voltage Threshold (Min.) |
14.8 V |
|
Turn-On Voltage Threshold (Typ.) |
15.4 V |
|
Turn-On Voltage Threshold (Max.) |
16.0 V |
|
Turn-Off Voltage Threshold (Min.) |
13.7 V |
|
Turn-Off Voltage Threshold (Typ.) |
14.5 V |
|
Turn-Off Voltage Threshold (Max.) |
15.1 V |
|
Lockout Voltage Hysteresis (Typ.) |
0.9 V |
|
Recommended External Input Capacitance (Typ.) |
47 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1-0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
1.0/3.9 uH uF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Non-Operating (Min.) |
-1 V |
|
Non-Operating (Max.) |
50 V |
|
Non-Operating (Notes & Conditions) |
Continuous |
|
Operating (Max.) |
40 V |
|
Operating (Notes & Conditions) |
Continuous |
|
Operating Transient (Max.) |
50 V |
|
Operating Transient (Notes & Conditions) |
100 ms |
|
Input to Output (Max.) |
2250 Vdc |
|
Input to Baseplate (Max.) |
2250 Vdc |
|
Output to Baseplate (Max.) |
2250 Vdc |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-45 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
8 V |
|
Turn-On Time (Typ.) |
40 ms |
|
Turn-On Time (Notes & Conditions) |
Full load, Vout=90% nom. (from enable) |
|
Start-Up Inhibit Time (Min.) |
100 ms |
|
Start-Up Inhibit Time (Typ.) |
120 ms |
|
Start-Up Inhibit Time (Max.) |
150 ms |
|
Start-Up Inhibit Time (Notes & Conditions) |
Figure E |
|
Power-Up Inhibit Time (Typ.) |
15 ms |
|
Power-Up Inhibit Time (Notes & Conditions) |
Figure E |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Typ.) |
30 M Ohm |
|
Isolation Capacitance (input to output) (Notes & Conditions) |
See Note 1 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
PCB Temperature (Max.) |
125 °C |
|
PCB Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Typ.) |
500 kHz |
|
Switching Frequency (Notes & Conditions) |
Isolation stage switching freq. is half this |
|
Off-State Voltage (Min.) |
1.5 V |
|
Off-State Voltage (Max.) |
8 V |
|
On-State Voltage (Min.) |
-2 V |
|
On-State Voltage (Max.) |
1 V |
|
ON/OFF Control (Notes & Conditions) |
Application notes Figures A & B |
|
Pull-Up Voltage (Typ.) |
5 V |
|
Pull-Up Resistance (Typ.) |
82.5 k Ohm |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF per MIL-HDBK-217F (Typ.) |
0.8 10^6 Hrs. |
|
Calculated MTBF per MIL-HDBK-217F (Notes & Conditions) |
Ground Mobile, 70°C Tb |
Features |
|
|
High efficiency up to 89% with integral baseplate for optimized conductive cooling performance. |
|
|
Wide 18-36 V input range featuring fixed-frequency switching for predictable EMI management. |
|
|
Industry-standard sixteenth-brick footprint available in standard and flanged baseplate configurations. |
|
|
Advanced control suite including remote sense, wide output voltage trim, and input-referenced On/Off. |
|
|
Robust protection circuitry including input UVLO, output current limiting, short circuit, OVP, and thermal shutdown. |
|
|
Certified safety compliance to UL/CSA/EN 62368-1 standards and full RoHS environmental compliance. |
|
|
Enhanced operational flexibility with no minimum load requirements and active back-drive current limiting. |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews
There are no reviews yet.