OP-2-48V-28V-S 34-75 V Input, 28 V/1.8 A Output Sixteenth-brick

$0

High efficiency operation (87% at full load) with minimal derating and no external heatsink requirement.
Wide 34-75V input voltage range with fixed-frequency switching for predictable EMI performance.
Industry-standard sixteenth-brick form factor with a compact footprint and optional flanged baseplate.
Advanced control features including remote sense, input-referenced On/Off, and +/-10% output voltage trim.
Comprehensive protection suite featuring input UVLO/OVLO, output current limit, short-circuit protection, and thermal shutdown.
Reliable performance with no minimum load requirement and integrated active back bias limiting.
Fully certified to UL/CSA/EN 62368-1 safety standards and RoHS compliant for global applications.

SKU: OP-2-48V-28V-S Category: converter

Description

The OP-2-48V-28V-S Sixteenth-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.

OP-2-48V-28V-S

OP-2-48V-28V-S 34-75 V Input, 28 V/1.8 A Output Sixteenth-brick

 

Property

Value

Maximum Input Current (Max.)

2.1 A

Maximum Input Current (Notes & Conditions)

Vin min; trim up; in current limit

No-Load Input Current (Typ.)

70 mA

No-Load Input Current (Max.)

90 mA

Disabled Input Current (Typ.)

10 mA

Disabled Input Current (Max.)

14 mA

Response to Input Transient (Typ.)

340 mV

Response to Input Transient (Notes & Conditions)

See Figure 6

Input Terminal Ripple Current (Typ.)

70 mA

Input Terminal Ripple Current (Notes & Conditions)

RMS

Recommended Input Fuse (Max.)

20 A

Recommended Input Fuse (Notes & Conditions)

Fast acting external fuse recommended

Output Voltage Set Point (Min.)

27.72 V

Output Voltage Set Point (Typ.)

28.00 V

Output Voltage Set Point (Max.)

28.28 V

Over Line (Typ.)

+/-0.1 %

Over Line (Max.)

+/-0.3 %

Over Load (Typ.)

+/-0.1 %

Over Load (Max.)

+/-0.3 %

Over Temperature (Min.)

-420 mV

Over Temperature (Max.)

420 mV

Total Output Voltage Range (Min.)

27.30 V

Total Output Voltage Range (Max.)

28.70 V

Total Output Voltage Range (Notes & Conditions)

Over sample, line, load, temperature & life

Output Voltage Ripple and Noise (Notes & Conditions)

20 MHz bandwidth

Peak-to-Peak (Min.)

0 mV

Peak-to-Peak (Typ.)

90 mV

Peak-to-Peak (Max.)

180 mV

Peak-to-Peak (Notes & Conditions)

Full load

RMS (Typ.)

25 mV

RMS (Max.)

50 mV

RMS (Notes & Conditions)

Full load

Operating Output Current Range (Min.)

0 A

Operating Output Current Range (Max.)

1.8 A

Operating Output Current Range (Notes & Conditions)

Subject to thermal derating

Output DC Current-Limit Inception (Min.)

1.9 A

Output DC Current-Limit Inception (Typ.)

2.2 A

Output DC Current-Limit Inception (Max.)

2.6 A

Output DC Current-Limit Inception (Notes & Conditions)

Output voltage 20% Low

Output DC Current-Limit Shutdown Voltage (Typ.)

22.4 V

Back-Drive Current Limit while Enabled (Typ.)

0.5 A

Back-Drive Current Limit while Enabled (Notes & Conditions)

Negative current drawn from output

Back-Drive Current Limit while Disabled (Typ.)

5 mA

Back-Drive Current Limit while Disabled (Notes & Conditions)

Negative current drawn from output

Maximum Output Capacitance (Max.)

500 uF

Maximum Output Capacitance (Notes & Conditions)

Vout nominal at full load (resistive load)

Settling Time (Typ.)

200 us

Settling Time (Notes & Conditions)

To within 1% Vout nom

Output Voltage Trim Range (Min.)

-10 %

Output Voltage Trim Range (Max.)

10 %

Output Voltage Trim Range (Notes & Conditions)

Across Pins 8&4; Common Figures 2-4

Output Voltage Remote Sense Range (Max.)

10 %

Output Voltage Remote Sense Range (Notes & Conditions)

Across Pins 8&4

Output Over-Voltage Protection (Min.)

33.6 V

Output Over-Voltage Protection (Typ.)

36.4 V

Output Over-Voltage Protection (Max.)

37.8 V

Output Over-Voltage Protection (Notes & Conditions)

Over full temp range

100% Load (Typ.)

85.5 %

100% Load (Notes & Conditions)

See Figure 1 for efficiency curve

50% Load (Typ.)

84 %

50% Load (Notes & Conditions)

See Figure 1 for efficiency curve

Operating Input Voltage Range (Min.)

34 V

Operating Input Voltage Range (Typ.)

48 V

Operating Input Voltage Range (Max.)

75 V

Turn-On Voltage Threshold (Min.)

31.2 V

Turn-On Voltage Threshold (Typ.)

32.5 V

Turn-On Voltage Threshold (Max.)

33.9 V

Turn-Off Voltage Threshold (Min.)

29.6 V

Turn-Off Voltage Threshold (Typ.)

31 V

Turn-Off Voltage Threshold (Max.)

32.2 V

Lockout Voltage Hysteresis (Typ.)

1.5 V

Input Over-Voltage Shutdown (Typ.)

– V

Input Over-Voltage Shutdown (Notes & Conditions)

Not Available

Recommended External Input Capacitance (Typ.)

100 uF

Recommended External Input Capacitance (Notes & Conditions)

Typical ESR 0.1-0.2 Ohm

Input Filter Component Values (LC) (Typ.)

1/3.94 uH uF

Input Filter Component Values (LC) (Notes & Conditions)

Internal values

Non-Operating (Max.)

100 V

Non-Operating (Notes & Conditions)

Continuous

Operating (Max.)

75 V

Operating (Notes & Conditions)

Continuous

Operating Transient Protection (Max.)

100 V

Isolation Voltage (Notes & Conditions)

Reinforced insulation

Input to Output (Max.)

2250 V dc

Input to Baseplate (Max.)

2250 V dc

Output to Baseplate (Max.)

2250 V dc

Operating Temperature (Min.)

-40 °C

Operating Temperature (Max.)

100 °C

Operating Temperature (Notes & Conditions)

Baseplate temperature

Storage Temperature (Min.)

-55 °C

Storage Temperature (Max.)

125 °C

Voltage at ON/OFF input pin (Min.)

-2 V

Voltage at ON/OFF input pin (Max.)

8 V

Turn-On Time (Typ.)

40 ms

Turn-On Time (Notes & Conditions)

Full load, Vout=90% nom.

Start-Up Inhibit Time (Min.)

100 ms

Start-Up Inhibit Time (Typ.)

120 ms

Start-Up Inhibit Time (Max.)

150 ms

Start-Up Inhibit Time (Notes & Conditions)

Figure F

Output Voltage Overshoot (Typ.)

0 %

Output Voltage Overshoot (Notes & Conditions)

Maximum Output Capacitance

Isolation Voltage (dielectric strength) (Notes & Conditions)

See Absolute Maximum Ratings

Isolation Resistance (Typ.)

30 M Ohm

Isolation Capacitance (input to output) (Notes & Conditions)

See Note 1

Semiconductor Junction Temperature (Max.)

125 °C

Semiconductor Junction Temperature (Notes & Conditions)

Package rated to 150 °C

Board Temperature (Max.)

125 °C

Board Temperature (Notes & Conditions)

UL rated max operating temp 130 °C

Transformer Temperature (Max.)

125 °C

Maximum Baseplate Temperature, Tb (Max.)

100 °C

Switching Frequency (Typ.)

500 kHz

Switching Frequency (Notes & Conditions)

Isolation stage switching freq. is half

Off-State Voltage (Min.)

1.5 V

Off-State Voltage (Max.)

8 V

On-State Voltage (Min.)

-2 V

On-State Voltage (Max.)

1 V

ON/OFF Control (Notes & Conditions)

Application notes Figures A & B

Pull-Up Voltage (Typ.)

5 V

Pull-Up Resistance (Typ.)

82.5 k Ohm

Over-Temperature Shutdown OTP Trip Point (Typ.)

125 °C

Over-Temperature Shutdown OTP Trip Point (Notes & Conditions)

Average PCB Temperature

Over-Temperature Shutdown Restart Hysteresis (Typ.)

10 °C

Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.)

3.80 10^6 Hrs.

Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions)

Tb = 70 °C

Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.)

0.68 10^6 Hrs.

Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions)

Tb = 70 °C

Step Change in Output Current (0.1 A/us) (Typ.)

550 mV

Step Change in Output Current (0.1 A/us) (Notes & Conditions)

50% to 75% to 50% Iout max

Features

High efficiency operation (87% at full load) with minimal derating and no external heatsink requirement.

Wide 34-75V input voltage range with fixed-frequency switching for predictable EMI performance.

Industry-standard sixteenth-brick form factor with a compact footprint and optional flanged baseplate.

Advanced control features including remote sense, input-referenced On/Off, and +/-10% output voltage trim.

Comprehensive protection suite featuring input UVLO/OVLO, output current limit, short-circuit protection, and thermal shutdown.

Reliable performance with no minimum load requirement and integrated active back bias limiting.

Fully certified to UL/CSA/EN 62368-1 safety standards and RoHS compliant for global applications.

Applications

Industrial and Transportation applications

Reviews

There are no reviews yet.


Be the first to review “OP-2-48V-28V-S 34-75 V Input, 28 V/1.8 A Output Sixteenth-brick”