OP-2-48V-2V-S 34-75 V Input, 1.8 V/25 A Output Sixteenth-brick
$0
High efficiency (87% at full load) with minimal power derating and no external heatsink required.
Wide 34-75V input range utilizing fixed-frequency switching for predictable EMI performance.
Enhanced control suite featuring remote sense, +/-10% output voltage trim, and input-side on/off control.
Operational flexibility with no minimum load requirement and integrated active back bias limiting.
Robust protection features including input UVLO/OVSD, output current limiting, short-circuit protection, and thermal shutdown.
Compact industry-standard sixteenth-brick form factor with an optional flanged baseplate.
Full compliance with UL/EN 62368-1 safety standards and RoHS directives.
- Description
- Reviews (0)
Description
The OP-2-48V-2V-S Sixteenth-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
OP-2-48V-2V-S |
|
|
OP-2-48V-2V-S 34-75 V Input, 1.8 V/25 A Output Sixteenth-brick |
|
Property |
Value |
|
Maximum Input Current (Max.) |
2.1 A |
|
Maximum Input Current (Notes & Conditions) |
Vin min; trim up; in current limit |
|
No-Load Input Current (Typ.) |
70 mA |
|
No-Load Input Current (Max.) |
90 mA |
|
Disabled Input Current (Typ.) |
10 mA |
|
Disabled Input Current (Max.) |
14 mA |
|
Response to Input Transient (Typ.) |
50 mV |
|
Response to Input Transient (Notes & Conditions) |
See Figure 6 |
|
Input Terminal Ripple Current (Typ.) |
70 mA |
|
Input Terminal Ripple Current (Notes & Conditions) |
RMS |
|
Recommended Input Fuse (Max.) |
20 A |
|
Recommended Input Fuse (Notes & Conditions) |
Fast acting external fuse recommended |
|
Output Voltage Set Point (Min.) |
1.782 V |
|
Output Voltage Set Point (Typ.) |
1.800 V |
|
Output Voltage Set Point (Max.) |
1.822 V |
|
Total Output Voltage Range (Min.) |
1.755 V |
|
Total Output Voltage Range (Max.) |
1.845 V |
|
Total Output Voltage Range (Notes & Conditions) |
Over sample, line, load, temperature & life |
|
Operating Output Current Range (Min.) |
0 A |
|
Operating Output Current Range (Max.) |
25 A |
|
Operating Output Current Range (Notes & Conditions) |
Subject to thermal derating |
|
Output DC Current-Limit Inception (Min.) |
31.7 A |
|
Output DC Current-Limit Inception (Typ.) |
37.9 A |
|
Output DC Current-Limit Inception (Max.) |
44.2 A |
|
Output DC Current-Limit Inception (Notes & Conditions) |
Output voltage 20% Low |
|
Output DC Current-Limit Shutdown Voltage (Typ.) |
1.4 V |
|
Back-Drive Current Limit while Enabled (Typ.) |
8 A |
|
Back-Drive Current Limit while Enabled (Notes & Conditions) |
Negative current drawn from output |
|
Back-Drive Current Limit while Disabled (Typ.) |
5 mA |
|
Back-Drive Current Limit while Disabled (Notes & Conditions) |
Negative current drawn from output |
|
Maximum Output Capacitance (Max.) |
10,000 uF |
|
Maximum Output Capacitance (Notes & Conditions) |
Vout nominal at full load (resistive load) |
|
Output Voltage Trim Range (Min.) |
–10 % |
|
Output Voltage Trim Range (Max.) |
10 % |
|
Output Voltage Trim Range (Notes & Conditions) |
Across Pins 8&4; Common Figures 2-4 |
|
Output Voltage Remote Sense Range (Max.) |
10 % |
|
Output Voltage Remote Sense Range (Notes & Conditions) |
Across Pins 8&4 |
|
Output Over-Voltage Protection (Min.) |
2.1 V |
|
Output Over-Voltage Protection (Typ.) |
2.2 V |
|
Output Over-Voltage Protection (Max.) |
2.3 V |
|
Output Over-Voltage Protection (Notes & Conditions) |
Over full temp range |
|
100% Load (Typ.) |
84.5 % |
|
100% Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
50% Load (Typ.) |
85 % |
|
50% Load (Notes & Conditions) |
See Figure 1 for efficiency curve |
|
Operating Input Voltage Range (Min.) |
34 V |
|
Operating Input Voltage Range (Typ.) |
48 V |
|
Operating Input Voltage Range (Max.) |
75 V |
|
Input Over-Voltage Shutdown (Typ.) |
– V |
|
Input Over-Voltage Shutdown (Notes & Conditions) |
Not Available |
|
Recommended External Input Capacitance (Typ.) |
100 uF |
|
Recommended External Input Capacitance (Notes & Conditions) |
Typical ESR 0.1-0.2 Ohm |
|
Input Filter Component Values (LC) (Typ.) |
1/3.94 uH uF |
|
Input Filter Component Values (LC) (Notes & Conditions) |
Internal values |
|
Operating Temperature (Min.) |
-40 °C |
|
Operating Temperature (Max.) |
100 °C |
|
Operating Temperature (Notes & Conditions) |
Baseplate temperature |
|
Storage Temperature (Min.) |
-55 °C |
|
Storage Temperature (Max.) |
125 °C |
|
Voltage at ON/OFF input pin (Min.) |
-2 V |
|
Voltage at ON/OFF input pin (Max.) |
8 V |
|
Output Voltage Overshoot (Typ.) |
0 % |
|
Output Voltage Overshoot (Notes & Conditions) |
Maximum Output Capacitance |
|
Isolation Voltage (dielectric strength) (Notes & Conditions) |
See Absolute Maximum Ratings |
|
Isolation Resistance (Typ.) |
30 M Ohm |
|
Isolation Capacitance (input to output) (Notes & Conditions) |
See Note 1 |
|
Semiconductor Junction Temperature (Max.) |
125 °C |
|
Semiconductor Junction Temperature (Notes & Conditions) |
Package rated to 150 °C |
|
Board Temperature (Max.) |
125 °C |
|
Board Temperature (Notes & Conditions) |
UL rated max operating temp 130 °C |
|
Transformer Temperature (Max.) |
125 °C |
|
Maximum Baseplate Temperature, Tb (Max.) |
100 °C |
|
Switching Frequency (Typ.) |
500 kHz |
|
Switching Frequency (Notes & Conditions) |
Isolation stage switching freq. is half |
|
Over-Temperature Shutdown OTP Trip Point (Typ.) |
125 °C |
|
Over-Temperature Shutdown OTP Trip Point (Notes & Conditions) |
Average PCB Temperature |
|
Over-Temperature Shutdown Restart Hysteresis (Typ.) |
10 °C |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Typ.) |
3.80 10^6 Hrs. |
|
Calculated MTBF (Telcordia) TR-NWT-000332 (Notes & Conditions) |
Tb = 70 °C |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Typ.) |
0.68 10^6 Hrs. |
|
Calculated MTBF (MIL-217) MIL-HDBK-217F (Notes & Conditions) |
Tb = 70 °C |
|
Output Voltage Regulation Over Line (Typ.) |
+/-0.1 % |
|
Output Voltage Regulation Over Line (Max.) |
+/-0.3 % |
|
Output Voltage Regulation Over Load (Typ.) |
+/-0.13 % |
|
Output Voltage Regulation Over Load (Max.) |
+/-0.5 % |
|
Output Voltage Regulation Over Temperature (Min.) |
–27 mV |
|
Output Voltage Regulation Over Temperature (Max.) |
27 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Min.) |
0 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Typ.) |
80 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Max.) |
160 mV |
|
Output Voltage Ripple and Noise Peak-to-Peak (Notes & Conditions) |
Full load; 20 MHz bandwidth |
|
Output Voltage Ripple and Noise RMS (Typ.) |
20 mV |
|
Output Voltage Ripple and Noise RMS (Max.) |
40 mV |
|
Output Voltage Ripple and Noise RMS (Notes & Conditions) |
Full load |
|
Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/ us) (Typ.) |
60 mV |
|
Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/ us) (Notes & Conditions) |
50% to 75% to 50% Iout max |
|
Output Voltage during Load Current Transient Settling Time (Typ.) |
100 us |
|
Output Voltage during Load Current Transient Settling Time (Notes & Conditions) |
To within 1% Vout nom |
|
Input Under-Voltage Lockout Turn-On Voltage Threshold (Min.) |
31.2 V |
|
Input Under-Voltage Lockout Turn-On Voltage Threshold (Typ.) |
32.5 V |
|
Input Under-Voltage Lockout Turn-On Voltage Threshold (Max.) |
33.9 V |
|
Input Under-Voltage Lockout Turn-Off Voltage Threshold (Min.) |
29.6 V |
|
Input Under-Voltage Lockout Turn-Off Voltage Threshold (Typ.) |
31 V |
|
Input Under-Voltage Lockout Turn-Off Voltage Threshold (Max.) |
32.2 V |
|
Input Under-Voltage Lockout Lockout Voltage Hysteresis (Typ.) |
1.5 V |
|
Input Voltage Non-Operating (Max.) |
100 V |
|
Input Voltage Non-Operating (Notes & Conditions) |
Continuous |
|
Input Voltage Operating (Max.) |
75 V |
|
Input Voltage Operating (Notes & Conditions) |
Continuous |
|
Input Voltage Operating Transient Protection (Max.) |
100 V |
|
Isolation Voltage Input to Output (Max.) |
2250 V dc |
|
Isolation Voltage Input to Output (Notes & Conditions) |
Reinforced insulation |
|
Isolation Voltage Input to Baseplate (Max.) |
2250 V dc |
|
Isolation Voltage Output to Baseplate (Max.) |
2250 V dc |
|
Turn-On Transient Turn-On Time (Typ.) |
40 ms |
|
Turn-On Transient Turn-On Time (Notes & Conditions) |
Full load, Vout=90% nom. |
|
Turn-On Transient Start-Up Inhibit Time (Min.) |
100 ms |
|
Turn-On Transient Start-Up Inhibit Time (Typ.) |
120 ms |
|
Turn-On Transient Start-Up Inhibit Time (Max.) |
150 ms |
|
Turn-On Transient Start-Up Inhibit Time (Notes & Conditions) |
Figure F |
|
ON/OFF Control Off-State Voltage (Min.) |
1.5 V |
|
ON/OFF Control Off-State Voltage (Max.) |
8 V |
|
ON/OFF Control On-State Voltage (Min.) |
-2 V |
|
ON/OFF Control On-State Voltage (Max.) |
1 V |
|
ON/OFF Control Pull-Up Voltage (Typ.) |
5 V |
|
ON/OFF Control Pull-Up Voltage (Notes & Conditions) |
Application notes Figures A & B |
|
ON/OFF Control Pull-Up Resistance (Typ.) |
82.5 k Ohm |
Features |
|
|
High efficiency (87% at full load) with minimal power derating and no external heatsink required. |
|
|
Wide 34-75V input range utilizing fixed-frequency switching for predictable EMI performance. |
|
|
Enhanced control suite featuring remote sense, +/-10% output voltage trim, and input-side on/off control. |
|
|
Operational flexibility with no minimum load requirement and integrated active back bias limiting. |
|
|
Robust protection features including input UVLO/OVSD, output current limiting, short-circuit protection, and thermal shutdown. |
|
|
Compact industry-standard sixteenth-brick form factor with an optional flanged baseplate. |
|
|
Full compliance with UL/EN 62368-1 safety standards and RoHS directives. |
|
Applications |
|
|
Industrial and Transportation applications |
|



Reviews
There are no reviews yet.